Cali-GrafCali-Graf
Solar panelLG Electronics

LG Electronics LG325N1T-L5

60 cells, bifacial. Power classes 310–345 W in the CEC list.

CEC listed · Oct 1, 2020UL 61730Bifacial
Power class
  • Power (STC)325 WCEC nameplate
  • Efficiency≈18.8%calculated from area
  • %/°C Pmax−0.360CEC listing test
  • PTC / STC92.4%PTC 300 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 8 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
LG310N1T-L5310 W40.6010.2232.309.61≈18.0%286 WOct 1, 2020
LG315N1T-L5315 W40.7010.2632.609.67≈18.3%291 WOct 1, 2020
LG320N1T-L5320 W40.8010.3032.909.73≈18.5%295 WOct 1, 2020
LG325N1T-L5325 W40.9010.3433.209.79≈18.8%300 WOct 1, 2020
LG330N1T-L5330 W41.0010.3833.509.85≈19.1%305 WOct 1, 2020
LG335N1T-L5335 W41.1010.4233.809.91≈19.4%310 WOct 1, 2020
LG340N1T-L5340 W41.2010.4634.109.97≈19.7%314 WOct 1, 2020
LG345N1T-L5345 W41.3010.5034.4010.03≈20.0%319 WOct 1, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.73 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.360 %/°C
Voc coefficient β−0.270 %/°C
Isc coefficient α+0.034 %/°C
Operating cell temperatureNOCT 46.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
310 W230.8 W30.15 V × 7.66 A60.8 W98%
315 W234.4 W30.43 V × 7.7 A61.7 W98%
320 W238.1 W30.71 V × 7.75 A62.7 W98%
325 W241.7 W30.99 V × 7.8 A63.6 W98%
330 W245.4 W31.27 V × 7.85 A64.6 W98%
335 W249.1 W31.55 V × 7.89 A65.6 W98%
340 W252.8 W31.83 V × 7.94 A66.5 W98%
345 W256.6 W32.11 V × 7.99 A67.5 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026)
UL 61730IEC 61215

Independent reliability testing

Kiwa PVEL Scorecard
2
PVEL Scorecards
LG Electronics named Top Performer, 2018–2021
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.4 V
Voc when cold
per panel
26.8 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.4 / 26.8 V⚠ Works; below MPPT at peak heat1.12
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.4 / 26.8 V✗ Not a match: module voltage below MPPT range0.86
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.4 / 26.8 V⚠ Works; below MPPT at peak heat0.42
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.4 / 26.8 V⚠ Works; below MPPT at peak heat1
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.4 / 26.8 V⚠ Works; below MPPT at peak heat0.93
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67654511,9836.08
Palmdale1,83559613,1206.69
Chula Vista1,69655112,1266.11
Huntington Beach1,64353411,7475.89
Riverside1,69655112,1266.21
Santa Clarita1,72456012,3276.28
782Jan783Feb1,005Mar1,110Apr1,096May1,165Jun1,227Jul1,241Aug1,085Sep957Oct823Nov712DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 325 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
LG Electronics LG325N1T-L5325 W≈18.8%−0.36040.910.34brand 2×—
JinkoSolar JKM325M-60HBL325 W≈19.3%−0.40741.110.2brand 12× (2014–2026)45
Qcells Q.PEAK DUO-G8+ 330330 W≈18.4%−0.34339.7110.52product 202220
REC Group REC325TP3M325 W≈20.2%−0.33639.510.36brand 9× (2016–2025)4
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the LG Electronics LG325N1T-L5?

Calculated from the panel area (1.73 m²): about 18.8% for the 325 W class. 325 W over 1.73 m² equals about 188 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 545 kWh per year per 325 W panel in Los Angeles and about 596 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.360 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.7% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.4 V, Vmp at 74 °C cell = 26.8 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; LG Electronics was named a Top Performer in 2 Scorecards (2018–2021).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Qcells — manufacturer datasheet “Q.PEAK DUO-G8+ 345-360 EN ENDURING HIGH”.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2018–2021.
  6. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).