Cali-GrafCali-Graf
Solar panelLG Electronics

LG Electronics LG340N1K-L5

60 cells, N-type. Power classes 310–355 W in the CEC list.

CEC listed · Jan 2, 2020UL 6173025-yr product + 25-yr performance warrantyN-typeSeen in 1 SoCal permit
Power class
  • Power (STC)340 WCEC nameplate
  • Efficiency≈19.7%calculated from area
  • %/°C Pmax−0.35CEC test: −0.343
  • Degradation / yr0.33%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 10 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
LG310N1K-L5310 W40.3010.3631.209.94≈17.9%288 WJan 2, 2020
LG315N1K-L5315 W40.4010.4031.609.97≈18.2%293 WJan 2, 2020
LG320N1K-L5320 W40.5010.4432.0010.01≈18.5%297 WJan 2, 2020
LG325N1K-L5325 W40.6010.4832.4010.04≈18.8%302 WJan 2, 2020
LG330N1K-L5330 W40.7010.5232.8010.07≈19.1%307 WJan 2, 2020
LG335N1K-L5335 W40.8010.5633.2010.10≈19.4%312 WJan 2, 2020
LG340N1K-L5340 W40.9010.6033.6010.12≈19.7%316 WJan 2, 2020
LG345N1K-L5345 W41.0010.6434.0010.15≈20.0%321 WJan 2, 2020
LG350N1K-L5350 W41.1010.6834.4010.18≈20.3%326 WJan 2, 2020
LG355N1K-L5355 W41.2010.7234.8010.21≈20.6%331 WJan 2, 2020
≈ efficiency = Pmax ÷ panel area 1.727 m² (datasheet size).

Build & dimensions

LG Electronics datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

LG Electronics datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.35 %/°C−0.343 %/°C
Voc coefficient β−0.26 %/°C−0.258 %/°C
Isc coefficient α+0.03 %/°C+0.025 %/°C
Vmp coefficient≈ −0.38 %/°C—
Operating cell temperatureNMOT 42 ± 3 °CNOCT 45.8 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
310 W233.7 W30.22 V × 7.74 A60.9 W98%
315 W237.5 W30.6 V × 7.76 A61.9 W98%
320 W241.4 W30.99 V × 7.79 A62.9 W98%
325 W245.2 W31.38 V × 7.81 A63.9 W98%
330 W248.9 W31.77 V × 7.84 A64.9 W98%
335 W252.7 W32.15 V × 7.86 A65.9 W98%
340 W256.3 W32.54 V × 7.88 A66.8 W98%
345 W260.1 W32.93 V × 7.9 A67.8 W98%
350 W263.9 W33.31 V × 7.92 A68.8 W98%
355 W267.8 W33.7 V × 7.95 A69.8 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

LG Electronics datasheet
Packaging: 25 per pallet

Certifications

CEC PV Module List (Oct 7, 2026) · LG Electronics datasheet
UL 61730UL 1703IEC 61215IEC 61730IEC 61701IEC 62716Fire rating Type 2 (UL 61730)ISO 14001ISO 45001ISO 9001

Warranty & degradation

LG Electronics datasheet · Cali-Graf calculation
85%89%92%96%100%051015202598% yr 195.03% yr 1090.08% yr 25years
  • Product warranty25 years
  • Performance warranty25 years
  • Year 1≥ 98%
  • Then≤ 0.33% / year
  • Year 10≥ 95.03%calculated from warranty terms
  • Year 25≥ 90.1%

Independent reliability testing

Kiwa PVEL Scorecard
2
PVEL Scorecards
LG Electronics named Top Performer, 2018–2021
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

LG Electronics datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.3 V
Voc when cold
per panel
27.3 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.3 / 27.3 V⚠ Works; below MPPT at peak heat1.17
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.3 / 27.3 V✗ Not a match: module voltage below MPPT range0.89
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.3 / 27.3 V⚠ Works; below MPPT at peak heat0.44
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.3 / 27.3 V⚠ Works; below MPPT at peak heat1.05
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.3 / 27.3 V⚠ Works; below MPPT at peak heat0.97
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67657011,9676.08
Palmdale1,83562413,1026.69
Chula Vista1,69657712,1096.11
Huntington Beach1,64355911,7315.89
Riverside1,69657712,1096.21
Santa Clarita1,72458612,3096.28
781Jan782Feb1,003Mar1,108Apr1,095May1,163Jun1,225Jul1,240Aug1,084Sep956Oct822Nov711DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 340 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · JinkoSolar datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
LG Electronics LG340N1K-L5340 W≈19.7%−0.34340.910.6brand 2×1
LONGi LR4-60HPB-340M340 W≈18.8%−0.33740.110.84product 2021, 2022193
JinkoSolar JKM340M-60HBL340 W≈20.1%−0.4064110.82brand 12× (2014–2026)45
REC Group REC340AA340 W≈20.2%−0.27943.110.09brand 9× (2016–2025)30
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the LG Electronics LG340N1K-L5?

Calculated from the panel area (1.73 m²): about 19.7% for the 340 W class. 340 W over 1.73 m² equals about 197 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 570 kWh per year per 340 W panel in Los Angeles and about 624 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.35 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.1% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.3 V, Vmp at 74 °C cell = 27.3 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

25 years on the product and 25 years on performance: at least 98% of rated power in year 1, then no more than 0.33% per year — at least 90.1% after 25 years (manufacturer datasheet).

How big and heavy is it?

66.9 × 40 × 1.57 in (1,700 × 1,016 × 40 mm), 39.7 lb (18 kg).

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; LG Electronics was named a Top Performer in 2 Scorecards (2018–2021).

What fire rating does it have?

UL 61730 fire rating Type 2 per datasheet.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. LG Electronics — manufacturer datasheet “LG340N1K-L5 LG345N1K-L5 LG350N1K-L5”.
  3. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  4. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2018–2021.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Jan 2023). Equipment matched from permit descriptions by model number.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).