60 cells, N-type. Power classes 345–380 W in the CEC list; datasheet covers 355–355 W.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| LG345N1K-A6 | 345 W | 41.40 | 10.76 | 33.50 | 10.32 | ≈19.0% | 319 W | Feb 1, 2021 |
| LG350N1K-A6 | 350 W | 41.50 | 10.80 | 33.90 | 10.35 | ≈19.3% | 324 W | Feb 1, 2021 |
| LG355N1K-A6 | 355 W | 41.60 | 10.84 | 34.30 | 10.37 | ≥19.6% | 329 W | Feb 1, 2021 |
| LG360N1K-A6 | 360 W | 41.70 | 10.88 | 34.70 | 10.39 | ≈19.9% | 333 W | Feb 1, 2021 |
| LG365N1K-A6 | 365 W | 41.80 | 10.92 | 35.10 | 10.41 | ≈20.1% | 338 W | Feb 1, 2021 |
| LG370N1K-A6 | 370 W | 41.90 | 10.96 | 35.50 | 10.43 | ≈20.4% | 343 W | Feb 1, 2021 |
| LG375N1K-A6 | 375 W | 42.00 | 11.00 | 35.90 | 10.45 | ≈20.7% | 346 W | Jul 1, 2021 |
| LG380N1K-A6 | 380 W | 42.10 | 11.04 | 36.30 | 10.47 | ≈21.0% | 351 W | Jul 1, 2021 |
| Datasheet | CEC listing test | |
|---|---|---|
| Pmax coefficient γ | −0.35 %/°C | −0.342 %/°C |
| Voc coefficient β | −0.26 %/°C | −0.255 %/°C |
| Isc coefficient α | +0.03 %/°C | +0.026 %/°C |
| Vmp coefficient | ≈ −0.38 %/°C | — |
| Operating cell temperature | NMOT 42 ± 3 °C | NOCT 48.7 °C |
| Class | Pmax, W | Voc, V | Isc, A | Vmp, V | Imp, A |
|---|---|---|---|---|---|
| 355 W | 266.0 | 39.20 | 8.72 | 32.20 | 8.27 |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 345 W | 259.4 W | 31.15 V × 8.33 A | 68.2 W | 99% |
| 350 W | 263.3 W | 31.53 V × 8.35 A | 69.2 W | 99% |
| 355 W | 266.9 W | 31.9 V × 8.37 A | 70.1 W | 99% |
| 360 W | 270.5 W | 32.27 V × 8.38 A | 71.1 W | 99% |
| 365 W | 274.2 W | 32.64 V × 8.4 A | 72.1 W | 99% |
| 370 W | 277.8 W | 33.01 V × 8.42 A | 73 W | 99% |
| 375 W | 267.2 W | 32.21 V × 8.3 A | 71 W | 95% |
| 380 W | 270.7 W | 32.57 V × 8.31 A | 72 W | 95% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–13 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–13 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–13 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 9–11 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 44.5 / 29.2 V | ✓ Within range | 1.29 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 44.5 / 29.2 V | ✗ Not a match: module voltage below MPPT range | 0.99 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 44.5 / 29.2 V | ✓ Within range | 0.48 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 44.5 / 29.2 V | ⚠ Works; below MPPT at peak heat | 1.15 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 44.5 / 29.2 V | ⚠ Works; below MPPT at peak heat | 1.07 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 628 | 11,942 | 6.08 |
| Palmdale | 1,835 | 688 | 13,074 | 6.69 |
| Chula Vista | 1,696 | 636 | 12,084 | 6.11 |
| Huntington Beach | 1,643 | 616 | 11,706 | 5.89 |
| Riverside | 1,696 | 636 | 12,084 | 6.21 |
| Santa Clarita | 1,724 | 646 | 12,284 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| LG Electronics LG375N1K-A6 | 375 W | ≈20.7% | −0.342 | 42 | 11 | brand 2× | 2 |
| Qcells Q.PEAK DUO BLK ML-G10+ 380 | 380 W | ≈19.4% | −0.362 | 45.16 | 11.01 | product 2022, 2023 | 221 |
| LONGi LR4-60HPB-370M | 370 W | ≈20.9% | −0.339 | 41.2 | 11.5 | product 2021, 2022 | 193 |
| REC Group REC380AA Pure | 380 W | ≈21.2% | −0.256 | 48.4 | 10.17 | brand 9× (2016–2025) | 66 |
Calculated from the panel area (1.81 m²): about 20.7% for the 375 W class. 375 W over 1.81 m² equals about 207 W per square meter.
PVWatts v8 with typical-year weather gives about 628 kWh per year per 375 W panel in Los Angeles and about 688 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.35 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.1% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44.5 V, Vmp at 74 °C cell = 29.2 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the Enphase datasheet: Voc when cold 44.5 V vs max input 60 V; Vmp when hot 29.2 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.
25 years on the product and 25 years on performance: at least 98.5% of rated power in year 1, then no more than 0.33% per year — at least 90.6% after 25 years (manufacturer datasheet).
68.5 × 41 × 1.57 in (1,740 × 1,042 × 40 mm), 41 lb (18.6 kg).
This exact series is not in published PVEL Top Performer tables; LG Electronics was named a Top Performer in 2 Scorecards (2018–2021).