LG Electronics LG360N1C-N5

60 cells, N-type. Power classes 320–370 W in the CEC list; datasheet covers 360–360 W.

CEC listed · Feb 3, 2020UL 6173025-yr product + 25-yr performance warrantyPVEL Top Performer 2021N-typeInstalled in 5 SoCal permits
Power class
  • Power (STC)360 WCEC nameplate
  • Efficiency≥20.8%datasheet minimum
  • %/°C Pmax−0.34CEC test: −0.342
  • Degradation / yr0.33%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · LG Electronics datasheet · 11 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
LG320N1C-N5320 W40.8010.5331.9010.04≈18.5%298 WAug 11, 2020
LG325N1C-N5325 W40.9010.5732.3010.07≈18.8%303 WAug 11, 2020
LG330N1C-N5330 W41.0010.6132.7010.10≈19.1%308 WFeb 3, 2020
LG335N1C-N5335 W41.1010.6533.1010.13≈19.4%313 WFeb 3, 2020
LG340N1C-N5340 W41.2010.6933.5010.16≈19.7%318 WAug 11, 2020
LG345N1C-N5345 W41.3010.7233.9010.19≈20.0%322 WFeb 3, 2020
LG350N1C-N5350 W41.4010.7634.3010.22≈20.3%327 WFeb 3, 2020
LG355N1C-N5355 W41.5010.8034.7010.25≈20.6%332 WFeb 3, 2020
LG360N1C-N5360 W41.6010.8435.1010.28≥20.8%337 WFeb 3, 2020
LG365N1C-N5365 W41.7010.8835.5010.30≈21.1%342 WAug 11, 2020
LG370N1C-N5370 W41.8010.9235.8010.34≈21.4%346 WAug 11, 2020
≈ efficiency = Pmax ÷ panel area 1.727 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

LG Electronics datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

LG Electronics datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.34 %/°C−0.342 %/°C
Voc coefficient β−0.26 %/°C−0.257 %/°C
Isc coefficient α+0.03 %/°C+0.032 %/°C
Vmp coefficient≈ −0.37 %/°C—
Operating cell temperatureNMOT 42 ± 3 °CNOCT 44.9 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

At normal operating conditions (NMOT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
360 W270.039.208.7133.008.20

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
320 W237.9 W30.05 V × 7.92 A62.4 W97%
325 W241.6 W30.43 V × 7.94 A63.3 W97%
330 W245.3 W30.81 V × 7.96 A64.3 W97%
335 W249 W31.18 V × 7.99 A65.3 W97%
340 W252.8 W31.56 V × 8.01 A66.3 W97%
345 W256.6 W31.94 V × 8.03 A67.3 W97%
350 W260.4 W32.31 V × 8.06 A68.3 W98%
355 W264.2 W32.69 V × 8.08 A69.3 W98%
360 W268 W33.07 V × 8.1 A70.3 W98%
365 W271.6 W33.44 V × 8.12 A71.2 W98%
370 W274.9 W33.73 V × 8.15 A72.1 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

LG Electronics datasheet
Packaging: 25 per pallet

Certifications

CEC PV Module List (Oct 7, 2026) · LG Electronics datasheet
UL 61730UL 1703IEC 61215IEC 61730IEC 61701IEC 62716Fire rating Type 1 (UL 61730)ISO 14001ISO 45001ISO 9001

Warranty & degradation

LG Electronics datasheet · Cali-Graf calculation
85%89%92%96%100%051015202598% yr 195.03% yr 1090.08% yr 25years
  • Product warranty25 years
  • Performance warranty25 years
  • Year 1≥ 98%
  • Then≤ 0.33% / year
  • Year 10≥ 95.03%calculated from warranty terms
  • Year 25≥ 90.1%

Independent reliability testing

Kiwa PVEL Scorecard
2021
PVEL Top Performer
this series
4
Tests passed as Top Performer
DH, LID+LETID, MSS, PID
2
PVEL Scorecards
LG Electronics named Top Performer, 2018–2021

PVEL Top Performer tests

YearProductTests
2021LGxxxN1C-N5DHLID+LETIDMSSPID

Inverter compatibility & string sizing

LG Electronics datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
44.1 V
Voc when cold
per panel
28.7 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V44.1 / 28.7 V⚠ Works; below MPPT at peak heat1.24
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V44.1 / 28.7 V✗ Not a match: module voltage below MPPT range0.95
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V44.1 / 28.7 V✓ Within range0.46
Enphase IQ8M-72-2-US260–460 W60 V30–45 V44.1 / 28.7 V⚠ Works; below MPPT at peak heat1.11
Enphase IQ8A-72-2-US295–500 W60 V32–45 V44.1 / 28.7 V⚠ Works; below MPPT at peak heat1.03
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67660311,4646.08
Palmdale1,83566112,5516.69
Chula Vista1,69661111,6016.11
Huntington Beach1,64359111,2385.89
Riverside1,69661111,6016.21
Santa Clarita1,72462111,7926.28
748Jan749Feb961Mar1,062Apr1,049May1,114Jun1,174Jul1,187Aug1,038Sep916Oct787Nov681DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs LGxxxN1C-N5 panels in SoCal

building permits
5
Permits naming this series
Dec 2020 – Jul 2021
1
Jurisdictions so far
LA County (unincorp.) (5)

Permits over time

1Dec ’202Jan ’210Feb0Mar0Apr1May0Jun1Julpermits per month

Power class named in permit

360 W
3
370 W
2
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Installed together with

building permits

Microinverters

Enphase IQ7+
4
Number of permits naming both this panel series and the product; 5 of 5 permits list other equipment.

Compare with similar 360 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
LG Electronics LG360N1C-N5360 W≥20.8%−0.34241.610.84product 20215
LONGi LR4-60HPB-360M360 W≈20.3%−0.33940.811.33product 2021, 2022193
REC Group REC360AA360 W≈21.4%−0.27944.110.23brand 9× (2016–2025)30
Trina Solar TSM-360DE06X.05(II)360 W≈19.8%−0.33944.810.3product 202223
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

Questions & answers

How efficient is the LG Electronics LG360N1C-N5?

The LG Electronics datasheet guarantees at least 20.8% module efficiency for the 360 W class. 360 W over 1.73 m² equals about 208 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 603 kWh per year per 360 W panel in Los Angeles and about 661 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.34 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44.1 V, Vmp at 74 °C cell = 28.7 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 44.1 V vs max input 60 V; Vmp when hot 28.7 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

What does the warranty cover?

25 years on the product and 25 years on performance: at least 98% of rated power in year 1, then no more than 0.33% per year — at least 90.1% after 25 years (manufacturer datasheet).

How big and heavy is it?

66.9 × 40 × 1.57 in (1,700 × 1,016 × 40 mm), 39.7 lb (18 kg).

Has this panel been reliability-tested?

LGxxxN1C-N5 was a PVEL Top Performer in 2021 (DH, LID+LETID, MSS, PID).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. LG Electronics — datasheet Specification Sheet.
  3. LG Electronics — document library on the manufacturer’s website (links above).
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2018–2021.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Dec 2020 – Jul 2021). Equipment matched from permit descriptions by model number.