60 cells, N-type. Power classes 355–385 W in the CEC list; datasheet covers 360–360 W.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| LG355N1C-A6 | 355 W | 41.40 | 11.19 | 33.70 | 10.54 | ≈19.6% | 328 W | Feb 1, 2021 |
| LG360N1C-A6 | 360 W | 41.50 | 11.23 | 34.10 | 10.56 | ≥19.9% | 333 W | Feb 1, 2021 |
| LG365N1C-A6 | 365 W | 41.60 | 11.27 | 34.50 | 10.58 | ≈20.1% | 338 W | Feb 1, 2021 |
| LG370N1C-A6 | 370 W | 41.70 | 11.31 | 34.90 | 10.61 | ≈20.4% | 343 W | Feb 1, 2021 |
| LG375N1C-A6 | 375 W | 41.80 | 11.35 | 35.30 | 10.63 | ≈20.7% | 347 W | Feb 1, 2021 |
| LG380N1C-A6 | 380 W | 41.90 | 11.39 | 35.70 | 10.65 | ≈21.0% | 352 W | Feb 1, 2021 |
| LG385N1C-A6 | 385 W | 42.00 | 11.43 | 36.10 | 10.67 | ≈21.2% | 357 W | Feb 1, 2021 |
| Datasheet | CEC listing test | |
|---|---|---|
| Pmax coefficient γ | −0.34 %/°C | −0.344 %/°C |
| Voc coefficient β | −0.26 %/°C | −0.259 %/°C |
| Isc coefficient α | +0.03 %/°C | +0.024 %/°C |
| Vmp coefficient | ≈ −0.37 %/°C | — |
| Operating cell temperature | NMOT 42 ± 3 °C | NOCT 47.4 °C |
| Class | Pmax, W | Voc, V | Isc, A | Vmp, V | Imp, A |
|---|---|---|---|---|---|
| 360 W | 269.7 | 39.10 | 9.03 | 32.00 | — |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 355 W | 259.3 W | 30.76 V × 8.43 A | 68.3 W | 96% |
| 360 W | 262.9 W | 31.12 V × 8.45 A | 69.3 W | 96% |
| 365 W | 266.5 W | 31.49 V × 8.46 A | 70.2 W | 96% |
| 370 W | 270.3 W | 31.85 V × 8.49 A | 71.2 W | 96% |
| 375 W | 273.9 W | 32.22 V × 8.5 A | 72.2 W | 96% |
| 380 W | 277.6 W | 32.59 V × 8.52 A | 73.1 W | 96% |
| 385 W | 281.2 W | 32.95 V × 8.53 A | 74.1 W | 96% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–13 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–13 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–13 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 9–11 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 44.4 / 29.2 V | ✓ Within range | 1.31 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 44.4 / 29.2 V | ✗ Not a match: module voltage below MPPT range | 1 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 44.4 / 29.2 V | ✓ Within range | 0.49 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 44.4 / 29.2 V | ⚠ Works; below MPPT at peak heat | 1.17 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 44.4 / 29.2 V | ⚠ Works; below MPPT at peak heat | 1.09 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 637 | 11,464 | 6.08 |
| Palmdale | 1,835 | 697 | 12,551 | 6.69 |
| Chula Vista | 1,696 | 644 | 11,601 | 6.11 |
| Huntington Beach | 1,643 | 624 | 11,238 | 5.89 |
| Riverside | 1,696 | 644 | 11,601 | 6.21 |
| Santa Clarita | 1,724 | 655 | 11,792 | 6.28 |
median 10.6 kW, 26 panels (n = 10)
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| LG Electronics LG380N1C-A6 | 380 W | ≈21% | −0.344 | 41.9 | 11.39 | brand 2× | 13 |
| Qcells Q.PEAK DUO BLK ML-G10+ 380 | 380 W | ≈19.4% | −0.362 | 45.16 | 11.01 | product 2022, 2023 | 221 |
| JA Solar JAM54S31-385/MR | 385 W | ≈20.3% | −0.329 | 36.71 | 13.52 | product 2023, 2024 | 152 |
| REC Group REC380AA Pure | 380 W | ≈21.2% | −0.256 | 48.4 | 10.17 | brand 9× (2016–2025) | 66 |
Calculated from the panel area (1.81 m²): about 21% for the 380 W class. 380 W over 1.81 m² equals about 210 W per square meter.
PVWatts v8 with typical-year weather gives about 637 kWh per year per 380 W panel in Los Angeles and about 697 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.34 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44.4 V, Vmp at 74 °C cell = 29.2 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the Enphase datasheet: Voc when cold 44.4 V vs max input 60 V; Vmp when hot 29.2 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.
25 years on the product and 25 years on performance: at least 98.5% of rated power in year 1, then no more than 0.33% per year — at least 90.6% after 25 years (manufacturer datasheet).
68.5 × 41 × 1.57 in (1,740 × 1,042 × 40 mm), 41 lb (18.6 kg).
This exact series is not in published PVEL Top Performer tables; LG Electronics was named a Top Performer in 2 Scorecards (2018–2021).