CEC PV Module List (Oct 7, 2026) · NLR SAM inverter library · Cali-Graf calculation
DC module insideLG360Q1K-V5
MicroinverterLM320UE-A2
Microinverter AC output322 W ACNLR SAM inverter library
DC/AC ratio1.12Pmax ÷ microinverter AC rating
The string calculator does not apply: each panel has its own microinverter, wired as AC branch circuits.
Build & dimensions
CEC PV Module List (Oct 7, 2026)
Module area1.67 m² (18 ft²)CEC-listed area
Cells60 cells
Back coverWhite backsheet
Heat & cold behaviour
CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ
−0.306 %/°C
Voc coefficient β
−0.243 %/°C
Isc coefficient α
+0.032 %/°C
Operating cell temperature
NOCT 49 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.
Away from lab conditions — CEC listing test points
Class
Pmax at NOCT
Vmp × Imp at NOCT
Pmax at 200 W/m²
Low-light efficiency vs STC
360 W
268.8 W
34.6 V × 7.77 A
68.3 W
95%
365 W
272.5 W
34.79 V × 7.83 A
69.2 W
95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).
Independent reliability testing
Kiwa PVEL Scorecard
2
PVEL Scorecards
LG Electronics named Top Performer, 2018–2021
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
603
11,464
6.08
Palmdale
1,835
661
12,551
6.69
Chula Vista
1,696
611
11,601
6.11
Huntington Beach
1,643
591
11,238
5.89
Riverside
1,696
611
11,601
6.21
Santa Clarita
1,724
621
11,792
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Questions & answers
How efficient is the LG Electronics LG360A1K-V5?
Calculated from the panel area (1.67 m²): about 21.6% for the 360 W class. 360 W over 1.67 m² equals about 216 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 603 kWh per year per 360 W panel in Los Angeles and about 661 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.306 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.9% below the STC rating.
What microinverter is built into the LG Electronics LG360A1K-V5?
The CEC listing names LM320UE-A2 paired with the LG360Q1K-V5 DC module; the microinverter is rated 322 W AC.
Has this panel been reliability-tested?
This exact series is not in published PVEL Top Performer tables; LG Electronics was named a Top Performer in 2 Scorecards (2018–2021).
Sources
California Energy Commission — Solar Equipment Lists, PV Module List (snapshot Oct 7, 2026).
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).