AC solar panelLG Electronics

LG Electronics LG400A1C-A6

60 cells, with a built-in LM320UE-A2 microinverter. Power classes 395–405 W in the CEC list.

CEC listed · May 11, 2021UL 1741AC module · built-in microinverter
Power class
  • Power (STC)400 WCEC nameplate
  • Efficiency≈22.1%calculated from area
  • %/°C Pmax−0.310CEC listing test
  • PTC / STC93.5%PTC 374 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 3 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
LG395A1C-A6395 W43.6011.2937.0010.69≈21.8%369 WMay 11, 2021
LG400A1C-A6400 W43.8011.3237.2010.76≈22.1%374 WMay 11, 2021
LG405A1C-A6405 W43.9011.3537.5010.82≈22.3%379 WMay 11, 2021
≈ efficiency = Pmax ÷ CEC-listed area 1.81 m².

Built-in microinverter

CEC PV Module List (Oct 7, 2026) · NLR SAM inverter library · Cali-Graf calculation
The string calculator does not apply: each panel has its own microinverter, wired as AC branch circuits.

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.310 %/°C
Voc coefficient β−0.242 %/°C
Isc coefficient α+0.027 %/°C
Operating cell temperatureNOCT 47.7 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
395 W294 W34.59 V × 8.5 A74.8 W95%
400 W297.5 W34.78 V × 8.55 A75.7 W95%
405 W301.6 W35.06 V × 8.6 A76.7 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard
2
PVEL Scorecards
LG Electronics named Top Performer, 2018–2021
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67667012,0676.08
Palmdale1,83573413,2126.69
Chula Vista1,69667812,2116.11
Huntington Beach1,64365711,8305.89
Riverside1,69667812,2116.21
Santa Clarita1,72469012,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Questions & answers

How efficient is the LG Electronics LG400A1C-A6?

Calculated from the panel area (1.81 m²): about 22.1% for the 400 W class. 400 W over 1.81 m² equals about 221 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 670 kWh per year per 400 W panel in Los Angeles and about 734 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.310 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 16.1% below the STC rating.

What microinverter is built into the LG Electronics LG400A1C-A6?

The CEC listing names LM320UE-A2 paired with the LG395Q1C-A6 DC module; the microinverter is rated 322 W AC.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; LG Electronics was named a Top Performer in 2 Scorecards (2018–2021).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List (snapshot Oct 7, 2026).
  2. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2018–2021.
  3. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  4. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  5. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).