CEC PV Module List (Oct 7, 2026) · NLR SAM inverter library · Cali-Graf calculation
DC module insideLG395Q1C-A6
MicroinverterLM320UE-A2
Microinverter AC output322 W ACNLR SAM inverter library
DC/AC ratio1.24Pmax ÷ microinverter AC rating
The string calculator does not apply: each panel has its own microinverter, wired as AC branch circuits.
Build & dimensions
CEC PV Module List (Oct 7, 2026)
Module area1.81 m² (19.5 ft²)CEC-listed area
Cells60 cells
Back coverWhite backsheet
Heat & cold behaviour
CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ
−0.310 %/°C
Voc coefficient β
−0.242 %/°C
Isc coefficient α
+0.027 %/°C
Operating cell temperature
NOCT 47.7 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.
Away from lab conditions — CEC listing test points
Class
Pmax at NOCT
Vmp × Imp at NOCT
Pmax at 200 W/m²
Low-light efficiency vs STC
395 W
294 W
34.59 V × 8.5 A
74.8 W
95%
400 W
297.5 W
34.78 V × 8.55 A
75.7 W
95%
405 W
301.6 W
35.06 V × 8.6 A
76.7 W
95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).
Independent reliability testing
Kiwa PVEL Scorecard
2
PVEL Scorecards
LG Electronics named Top Performer, 2018–2021
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
670
12,067
6.08
Palmdale
1,835
734
13,212
6.69
Chula Vista
1,696
678
12,211
6.11
Huntington Beach
1,643
657
11,830
5.89
Riverside
1,696
678
12,211
6.21
Santa Clarita
1,724
690
12,413
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Questions & answers
How efficient is the LG Electronics LG400A1C-A6?
Calculated from the panel area (1.81 m²): about 22.1% for the 400 W class. 400 W over 1.81 m² equals about 221 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 670 kWh per year per 400 W panel in Los Angeles and about 734 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.310 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 16.1% below the STC rating.
What microinverter is built into the LG Electronics LG400A1C-A6?
The CEC listing names LM320UE-A2 paired with the LG395Q1C-A6 DC module; the microinverter is rated 322 W AC.
Has this panel been reliability-tested?
This exact series is not in published PVEL Top Performer tables; LG Electronics was named a Top Performer in 2 Scorecards (2018–2021).
Sources
California Energy Commission — Solar Equipment Lists, PV Module List (snapshot Oct 7, 2026).
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.