Cali-GrafCali-Graf
Solar panelLa Solar

La Solar LS450HC

144 half-cut cells, PERC. Power classes 430–450 W in the CEC list; datasheet covers 450–450 W.

CEC listed · Aug 23, 2021UL 61730PERCInstalled in 1 SoCal permit
Power class
  • Power (STC)450 WCEC nameplate
  • Efficiency≥20.6%datasheet minimum
  • %/°C Pmax−0.37CEC test: −0.358
  • Performance warranty25 yrdatasheet

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · La Solar datasheet · 5 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
LS430HC430 W48.8011.2440.3010.66≈19.5%401 WAug 23, 2021
LS435HC435 W49.0011.3140.5010.74≈19.7%406 WAug 23, 2021
LS440HC440 W49.2011.3940.7010.82≈19.9%411 WAug 23, 2021
LS445HC445 W49.4011.4640.8010.90≈20.1%416 WAug 23, 2021
LS450HC450 W49.6011.5341.0010.98≥20.6%420 WAug 23, 2021
≈ efficiency = Pmax ÷ panel area 2.209 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

La Solar datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

La Solar datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.37 %/°C−0.358 %/°C
Voc coefficient β−0.28 %/°C−0.374 %/°C
Isc coefficient α+0.04 %/°C+0.049 %/°C
Vmp coefficient≈ −0.41 %/°C—
Operating cell temperature—NOCT 44.1 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
430 W323.4 W40.1 V × 8.07 A82.2 W96%
435 W327.5 W40.3 V × 8.13 A83.2 W96%
440 W331.6 W40.5 V × 8.19 A84.3 W96%
445 W334.8 W40.6 V × 8.25 A85.1 W96%
450 W338.9 W40.8 V × 8.31 A86.2 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

La Solar datasheet
Packaging: 26 per pallet · 520 per container

Certifications

CEC PV Module List (Oct 7, 2026) · La Solar datasheet
UL 61730IEC 61215IEC 61730IEC 62804Fire rating Type 1 (UL 61730)ISO 14001ISO 45001ISO 9001

Warranty & degradation

La Solar datasheet

Inverter compatibility & string sizing

La Solar datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.8 V
Voc when cold
per panel
32.8 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V52.8 / 32.8 V✗ Not a match: module voltage below MPPT range1.18
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V52.8 / 32.8 V✓ Within range0.58
Enphase IQ8M-72-2-US260–460 W60 V30–45 V52.8 / 32.8 V✓ Within range1.38
Enphase IQ8A-72-2-US295–500 W60 V32–45 V52.8 / 32.8 V✓ Within range1.29
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67675412,0676.08
Palmdale1,83582613,2126.69
Chula Vista1,69676312,2116.11
Huntington Beach1,64373911,8305.89
Riverside1,69676312,2116.21
Santa Clarita1,72477612,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs LSxxxHC panels in SoCal

building permits · CSLB License Master
1
Permits naming this series
Jul 2021
1
Licensed installers
CSLB license on the permit
1
Jurisdictions so far
Los Angeles (1)
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Counts grow as more permit portals are loaded.

Compare with similar 450 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
La Solar LS450HC450 W≥20.6%−0.35849.611.53—1
Qcells Q.TRON BLK M-G2+ 445445 W≈22.8%−0.27640.1613.98brand 11× (2016–2026)40
Hyundai Energy Solutions HiN-T450NF(BK)450 W≈23.2%−0.29839.214.53brand 5× (2017–2025)37
REC Group REC450AA Pure-RX450 W≈22.3%−0.24865.18.81brand 9× (2016–2025)33
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the La Solar LS450HC?

The La Solar datasheet guarantees at least 20.6% module efficiency for the 450 W class. 450 W over 2.21 m² equals about 204 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 754 kWh per year per 450 W panel in Los Angeles and about 826 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.37 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.8 V, Vmp at 74 °C cell = 32.8 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.8 V vs max input 60 V; Vmp when hot 32.8 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

What does the warranty cover?

25 years on performance (manufacturer datasheet).

How big and heavy is it?

83 × 41.3 × 1.57 in (2,108 × 1,048 × 40 mm), 52.9 lb (24 kg).

What fire rating does it have?

UL 61730 fire rating Type 1 per datasheet.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. La Solar — manufacturer datasheet “LA SOLAR MONO MODULE LS450HC”.
  3. La Solar — manufacturer datasheet “Descrip�on LA SOLAR Model LS450HC(166) MONO MODULE”.
  4. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  5. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  6. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — LADBS, City of Los Angeles (Jul 2021). Equipment matched from permit descriptions by model number.
  11. Contractors State License Board — License Master (contractor names and license status), as of Oct 5, 2026.
  12. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).