Cali-GrafCali-Graf
Solar panelLa Solar

La Solar LS450BL

108 half-cut cells. Power classes 390–550 W in the CEC list.

CEC listed · Feb 11, 2022UL 61730Installed in 1 SoCal permit
Power class
  • Power (STC)450 WCEC nameplate
  • Efficiency≈20.5%calculated from area
  • %/°C Pmax−0.352CEC listing test
  • PTC / STC93.6%PTC 421 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 15 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
LS390BL390 W36.7013.5930.5312.78≈19.9%368 WMay 1, 2026
LS395BL395 W36.9013.6630.7012.87≈20.2%372 WMay 1, 2026
LS400BL400 W37.1013.7330.8712.96≈20.4%377 WMay 1, 2026
LS405BL405 W37.3013.8130.8713.06≈20.7%382 WMay 1, 2026
LS410BL410 W37.5013.8831.2013.15≈20.9%387 WMay 1, 2026
LS430BL430 W48.8011.2440.3010.66≈19.6%402 WFeb 11, 2022
LS435BL435 W49.0011.3140.5010.74≈19.9%407 WFeb 11, 2022
LS440BL440 W49.2011.3940.7010.82≈20.1%412 WFeb 11, 2022
LS445BL445 W49.4011.4640.8010.90≈20.3%416 WFeb 11, 2022
LS450BL450 W49.6011.5341.0010.98≈20.5%421 WFeb 11, 2022
LS530BL530 W49.3013.6041.0312.92≈20.5%498 WFeb 13, 2023
LS535BL535 W49.4013.7041.2912.96≈20.7%503 WFeb 13, 2023
LS540BL540 W49.5013.8141.5513.00≈20.9%508 WFeb 13, 2023
LS545BL545 W49.6013.9241.8113.04≈21.1%513 WFeb 13, 2023
LS550BL550 W49.7014.0242.0713.08≈21.3%518 WFeb 13, 2023
≈ efficiency = Pmax ÷ CEC-listed area 1.96 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.352 %/°C
Voc coefficient β−0.292 %/°C
Isc coefficient α+0.051 %/°C
Operating cell temperatureNOCT 44.1 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
390 W294.9 W29.09 V × 10.14 A74.4 W95%
395 W298.6 W29.25 V × 10.21 A75.3 W95%
400 W302.4 W29.41 V × 10.28 A76.3 W95%
405 W304.7 W29.41 V × 10.36 A76.9 W95%
410 W310.1 W29.72 V × 10.43 A78.2 W95%
430 W322.5 W39.96 V × 8.07 A82.2 W96%
435 W326.5 W40.16 V × 8.13 A83.3 W96%
440 W330.5 W40.36 V × 8.19 A84.3 W96%
445 W333.8 W40.45 V × 8.25 A85.1 W96%
450 W337.9 W40.65 V × 8.31 A86.2 W96%
530 W389.4 W37.78 V × 10.31 A97.9 W92%
535 W393 W38.01 V × 10.34 A98.9 W92%
540 W396.7 W38.25 V × 10.37 A99.8 W92%
545 W400.4 W38.49 V × 10.4 A100.7 W92%
550 W404.2 W38.73 V × 10.43 A101.7 W92%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.9 V
Voc when cold
per panel
32.9 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V52.9 / 32.9 V✗ Not a match: module voltage below MPPT range1.18
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V52.9 / 32.9 V✓ Within range0.58
Enphase IQ8M-72-2-US260–460 W60 V30–45 V52.9 / 32.9 V✓ Within range1.38
Enphase IQ8A-72-2-US295–500 W60 V32–45 V52.9 / 32.9 V✓ Within range1.29
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67675412,0676.08
Palmdale1,83582613,2126.69
Chula Vista1,69676312,2116.11
Huntington Beach1,64373911,8305.89
Riverside1,69676312,2116.21
Santa Clarita1,72477612,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs LSxxxBL panels in SoCal

building permits · CSLB License Master
1
Permits naming this series
Dec 2025
1
Licensed installers
CSLB license on the permit
1
Jurisdictions so far
Palmdale (1)
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Counts grow as more permit portals are loaded.

Compare with similar 450 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
La Solar LS450BL450 W≈20.5%−0.35249.611.53—1
Qcells Q.TRON BLK M-G2+ 445445 W≈22.8%−0.27640.1613.98brand 11× (2016–2026)40
Hyundai Energy Solutions HiN-T450NF(BK)450 W≈23.2%−0.29839.214.53brand 5× (2017–2025)37
REC Group REC450AA Pure-RX450 W≈22.3%−0.24865.18.81brand 9× (2016–2025)33
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the La Solar LS450BL?

Calculated from the panel area (2.19 m²): about 20.5% for the 450 W class. 450 W over 2.19 m² equals about 205 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 754 kWh per year per 450 W panel in Los Angeles and about 826 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.352 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.9 V, Vmp at 74 °C cell = 32.9 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.9 V vs max input 60 V; Vmp when hot 32.9 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Who installs it in Southern California?

Building permits name this series 1 times (Dec 2025). The most active licensed installers are Gp Renewables LLC.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  3. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — City of Palmdale (Dec 2025). Equipment matched from permit descriptions by model number.
  9. Contractors State License Board — License Master (contractor names and license status), as of Oct 5, 2026.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).