Cali-GrafCali-Graf
Solar panelKOSOL ENERGIE

KOSOL ENERGIE KE260P

48 cells. Power classes 200–345 W in the CEC list.

CEC listed · Mar 1, 2022UL 61730
Power class
  • Power (STC)260 WCEC nameplate
  • Efficiency≈16.0%calculated from area
  • %/°C Pmax−0.363CEC listing test
  • PTC / STC92%PTC 239 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 24 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
KE200P200 W29.628.6424.718.17≈15.3%184 WMar 1, 2022
KE205P205 W29.868.7724.928.30≈15.6%188 WMar 1, 2022
KE210P210 W30.108.9025.138.43≈16.0%193 WMar 1, 2022
KE215P215 W30.349.0325.348.56≈16.4%198 WMar 1, 2022
KE220P220 W30.589.1625.558.69≈16.8%203 WMar 1, 2022
KE225P225 W30.829.2925.768.82≈17.2%207 WMar 1, 2022
KE235P235 W33.788.8828.208.41≈16.1%216 WMar 1, 2022
KE240P240 W34.019.0028.408.53≈16.4%221 WMar 1, 2022
KE245P245 W34.249.1228.608.65≈16.8%226 WMar 1, 2022
KE250P250 W34.479.2428.808.77≈17.1%230 WMar 1, 2022
KE255P255 W34.709.3629.008.89≈17.5%235 WMar 1, 2022
KE260P260 W37.509.0030.708.50≈16.0%239 WMar 1, 2022
KE265P265 W37.709.1530.908.61≈16.3%244 WMar 1, 2022
KE270P270 W37.909.2231.008.73≈16.6%249 WMar 1, 2022
KE275P275 W38.109.3231.208.84≈16.9%253 WMar 1, 2022
KE280P280 W38.209.4031.508.92≈17.2%258 WMar 1, 2022
KE285P285 W38.409.4931.659.02≈17.5%263 WMar 1, 2022
KE315P315 W45.609.0037.208.51≈16.3%290 WMar 1, 2022
KE320P320 W45.509.1537.208.63≈16.6%295 WMar 1, 2022
KE325P325 W45.609.1937.308.73≈16.8%299 WMar 1, 2022
KE330P330 W45.809.2837.508.83≈17.1%304 WMar 1, 2022
KE335P335 W46.009.3537.708.91≈17.4%309 WMar 1, 2022
KE340P340 W46.209.4237.908.99≈17.6%314 WMar 1, 2022
KE345P345 W46.409.4938.109.07≈17.9%318 WMar 1, 2022
≈ efficiency = Pmax ÷ CEC-listed area 1.31 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.363 %/°C
Voc coefficient β−0.273 %/°C
Isc coefficient α+0.033 %/°C
Operating cell temperatureNOCT 46.4 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
200 W145.4 W22.44 V × 6.48 A38.2 W95%
205 W149 W22.63 V × 6.58 A39.1 W95%
210 W152.6 W22.82 V × 6.69 A40 W95%
215 W156.2 W23.01 V × 6.79 A41 W95%
220 W159.9 W23.2 V × 6.89 A42 W95%
225 W163.7 W23.39 V × 7 A42.9 W95%
235 W165.3 W25.57 V × 6.47 A43.3 W92%
240 W168.9 W25.75 V × 6.56 A44.2 W92%
245 W172.4 W25.93 V × 6.65 A45.1 W92%
250 W176 W26.11 V × 6.74 A46.1 W92%
255 W179.7 W26.29 V × 6.83 A47 W92%
260 W186.4 W27.97 V × 6.66 A49.3 W95%
265 W190 W28.16 V × 6.75 A50.3 W95%
270 W193.3 W28.25 V × 6.84 A51.2 W95%
275 W197 W28.43 V × 6.93 A52.1 W95%
280 W200.7 W28.7 V × 6.99 A53.1 W95%
285 W203.9 W28.84 V × 7.07 A54 W95%
315 W226.4 W34 V × 6.66 A59.9 W95%
320 W229.6 W34 V × 6.75 A60.7 W95%
325 W232.9 W34.09 V × 6.83 A61.6 W95%
330 W236.8 W34.27 V × 6.91 A62.6 W95%
335 W240.2 W34.45 V × 6.97 A63.5 W95%
340 W243.7 W34.64 V × 7.04 A64.4 W95%
345 W247.1 W34.82 V × 7.1 A65.3 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
39.9 V
Voc when cold
per panel
24.7 V
Vmp when hot
per panel
15
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–15
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–15
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet5–15
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window10–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V39.9 / 24.7 V⚠ Works; below MPPT at peak heat0.9
Enphase IQ8M-72-2-US260–460 W60 V30–45 V39.9 / 24.7 V⚠ Works; below MPPT at peak heat0.8
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67643611,7666.08
Palmdale1,83547712,8826.69
Chula Vista1,69644111,9066.11
Huntington Beach1,64342711,5345.89
Riverside1,69644111,9066.21
Santa Clarita1,72444812,1026.28
768Jan769Feb986Mar1,090Apr1,076May1,144Jun1,205Jul1,219Aug1,066Sep940Oct808Nov699DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 260 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, A
KOSOL ENERGIE KE260P260 W≈16%−0.36337.59
Hyundai Energy Solutions HiS-C265RG(BK)265 W≥16.4%−0.38237.988.95
ZNShine Solar ZXM6-72-265/M265 W≈13.3%−0.52444.148.22
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the KOSOL ENERGIE KE260P?

Calculated from the panel area (1.63 m²): about 16% for the 260 W class. 260 W over 1.63 m² equals about 160 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 436 kWh per year per 260 W panel in Los Angeles and about 477 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.363 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.8% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–15 panels per string (Voc at 2 °C = 39.9 V, Vmp at 74 °C cell = 24.7 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Hyundai Energy Solutions — datasheet [Customized Module] RG(BK) Series (PERC) 265~285W.
  3. ZNShine Solar — manufacturer datasheet “ZXM6-72 Series Znshinesolar 5BB Monocrystalline PV Module”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).