Cali-GrafCali-Graf
Solar panelKOSOL ENERGIE

KOSOL ENERGIE KE315M

48 cells. Power classes 230–400 W in the CEC list.

CEC listed · Mar 1, 2022UL 61730
Power class
  • Power (STC)315 WCEC nameplate
  • Efficiency≈19.3%calculated from area
  • %/°C Pmax−0.337CEC listing test
  • PTC / STC93%PTC 293 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 30 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
KE230M230 W30.519.4825.758.97≈17.6%214 WMar 1, 2022
KE235M235 W30.859.5626.109.03≈17.9%218 WMar 1, 2022
KE240M240 W31.159.6426.419.09≈18.3%223 WMar 1, 2022
KE245M245 W31.559.7226.809.15≈18.7%228 WMar 1, 2022
KE250M250 W32.009.8027.239.21≈19.1%232 WMar 1, 2022
KE255M255 W32.459.8827.669.27≈19.5%237 WMar 1, 2022
KE270M270 W38.709.2631.408.76≈18.5%251 WMar 1, 2022
KE275M275 W38.709.2631.408.76≈18.8%256 WMar 1, 2022
KE280M280 W39.009.3531.708.84≈19.2%260 WMar 1, 2022
KE285M285 W39.309.4531.808.97≈19.5%265 WMar 1, 2022
KE295M295 W39.709.5532.509.08≈18.1%274 WMar 1, 2022
KE300M300 W39.909.6432.609.19≈18.4%279 WMar 1, 2022
KE305M305 W40.009.8532.909.28≈18.7%284 WMar 1, 2022
KE310M310 W40.209.9433.109.37≈19.0%288 WMar 1, 2022
KE315M315 W40.509.9533.309.46≈19.3%293 WMar 1, 2022
KE320M320 W40.809.9633.709.55≈19.6%298 WMar 1, 2022
KE325M325 W41.109.9733.809.64≈19.9%303 WMar 1, 2022
KE340M340 W46.509.4538.208.90≈17.3%316 WMar 1, 2022
KE345M345 W46.709.5038.409.00≈17.5%320 WMar 1, 2022
KE350M350 W46.909.6038.509.09≈17.8%325 WMar 1, 2022
KE355M355 W47.009.6938.709.17≈18.0%330 WMar 1, 2022
KE360M360 W47.709.7039.009.24≈18.3%334 WMar 1, 2022
KE365M365 W48.009.8839.309.77≈18.5%339 WMar 1, 2022
KE370M370 W48.309.8339.709.33≈18.8%344 WMar 1, 2022
KE375M375 W48.509.8841.109.37≈19.0%349 WMar 1, 2022
KE380M380 W48.909.9040.509.39≈19.3%354 WMar 1, 2022
KE385M385 W49.109.9240.809.44≈19.5%358 WMar 1, 2022
KE390M390 W49.309.9341.209.47≈19.8%363 WMar 1, 2022
KE395M395 W49.509.9341.509.52≈20.1%368 WMar 1, 2022
KE400M400 W49.709.9441.809.57≈20.3%373 WMar 1, 2022
≈ efficiency = Pmax ÷ CEC-listed area 1.31 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.337 %/°C
Voc coefficient β−0.248 %/°C
Isc coefficient α+0.030 %/°C
Operating cell temperatureNOCT 46.1 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
230 W162.3 W23.36 V × 6.95 A43.9 W95%
235 W165.7 W23.68 V × 7 A44.8 W95%
240 W168.7 W23.96 V × 7.04 A45.6 W95%
245 W172.4 W24.31 V × 7.09 A46.6 W95%
250 W176.3 W24.7 V × 7.14 A47.6 W95%
255 W180.2 W25.09 V × 7.18 A48.7 W95%
270 W187.4 W26.71 V × 7.02 A50.4 W93%
275 W187.4 W26.71 V × 7.02 A50.4 W92%
280 W190.9 W26.97 V × 7.08 A51.3 W92%
285 W194.4 W27.06 V × 7.18 A52.3 W92%
295 W209.8 W29.91 V × 7.02 A55.9 W95%
300 W213 W30 V × 7.1 A56.8 W95%
305 W217.1 W30.28 V × 7.17 A57.9 W95%
310 W220.5 W30.46 V × 7.24 A58.8 W95%
315 W224 W30.64 V × 7.31 A59.7 W95%
320 W228.8 W31.01 V × 7.38 A61 W95%
325 W231.7 W31.1 V × 7.45 A61.7 W95%
340 W249.7 W35.07 V × 7.12 A67.6 W99%
345 W253.8 W35.26 V × 7.2 A68.7 W100%
350 W257 W35.35 V × 7.27 A69.6 W99%
355 W260.6 W35.53 V × 7.33 A70.6 W99%
360 W264.6 W35.81 V × 7.39 A71.7 W100%
365 W282 W36.08 V × 7.81 A76.4 W105%
370 W261.3 W35.49 V × 7.36 A70.5 W95%
375 W271.7 W36.75 V × 7.39 A73.3 W98%
380 W268.3 W36.21 V × 7.41 A72.3 W95%
385 W271.7 W36.48 V × 7.45 A73.3 W95%
390 W275.3 W36.84 V × 7.47 A74.2 W95%
395 W278.7 W37.1 V × 7.51 A75.1 W95%
400 W282.2 W37.37 V × 7.55 A76.1 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
42.8 V
Voc when cold
per panel
27.3 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V42.8 / 27.3 V⚠ Works; below MPPT at peak heat1.09
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V42.8 / 27.3 V⚠ Works; below MPPT at peak heat0.4
Enphase IQ8M-72-2-US260–460 W60 V30–45 V42.8 / 27.3 V⚠ Works; below MPPT at peak heat0.97
Enphase IQ8A-72-2-US295–500 W60 V32–45 V42.8 / 27.3 V⚠ Works; below MPPT at peak heat0.9
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67652811,6156.08
Palmdale1,83557812,7176.69
Chula Vista1,69653411,7536.11
Huntington Beach1,64351811,3865.89
Riverside1,69653411,7536.21
Santa Clarita1,72454311,9476.28
758Jan759Feb974Mar1,076Apr1,062May1,129Jun1,189Jul1,203Aug1,052Sep928Oct798Nov690DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 315 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
KOSOL ENERGIE KE315M315 W≈19.3%−0.33740.59.95——
JinkoSolar JKM315M-60HBL315 W≈18.7%−0.40740.710.04brand 12× (2014–2026)45
LG Electronics LG320N1C-N5320 W≈18.5%−0.34240.810.53product 20215
REC Group REC315NP315 W≈19.4%−0.35140.510.09brand 9× (2016–2025)4
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the KOSOL ENERGIE KE315M?

Calculated from the panel area (1.63 m²): about 19.3% for the 315 W class. 315 W over 1.63 m² equals about 193 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 528 kWh per year per 315 W panel in Los Angeles and about 578 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.337 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 42.8 V, Vmp at 74 °C cell = 27.3 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. LG Electronics — datasheet Specification Sheet.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).