144 half-cut cells, bifacial. Power classes 575–600 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| JW-HD144N-R0-575 | 575 W | 51.70 | 13.79 | 43.80 | 13.12 | ≈22.3% | 544 W | Jun 23, 2025 |
| JW-HD144N-R0-580 | 580 W | 52.50 | 13.95 | 43.90 | 13.22 | ≈22.5% | 549 W | Jun 23, 2025 |
| JW-HD144N-R0-585 | 585 W | 52.70 | 14.01 | 44.00 | 13.29 | ≈22.7% | 554 W | Jun 23, 2025 |
| JW-HD144N-R0-590 | 590 W | 52.40 | 13.94 | 44.40 | 13.28 | ≈22.9% | 558 W | Jun 23, 2025 |
| JW-HD144N-R0-595 | 595 W | 52.60 | 13.99 | 44.60 | 13.33 | ≈23.1% | 563 W | Jun 23, 2025 |
| JW-HD144N-R0-600 | 600 W | 52.80 | 14.04 | 44.80 | 13.39 | ≈23.3% | 568 W | Jun 23, 2025 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.320 %/°C |
| Voc coefficient β | −0.238 %/°C |
| Isc coefficient α | +0.046 %/°C |
| Operating cell temperature | NOCT 43.3 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 575 W | 429.7 W | 41.2 V × 10.43 A | 112.6 W | 98% |
| 580 W | 434.3 W | 41.4 V × 10.49 A | 113.8 W | 98% |
| 585 W | 437.4 W | 41.5 V × 10.54 A | 114.6 W | 98% |
| 590 W | 449.4 W | 42.2 V × 10.65 A | 117.8 W | 100% |
| 595 W | 445.2 W | 42 V × 10.6 A | 116.8 W | 98% |
| 600 W | 441.4 W | 41.8 V × 10.56 A | 115.9 W | 97% |
| Year | Product | Tests |
|---|---|---|
| 2025 | JW-HD144N-R0-xxx | DHHSSLID+LETIDMSSPANPID |
| 2026 | JW-HD144N-R0-xxxS (closely related product name) | HSSMSS |
| 2025 | JW-HD144N-R0-xxx (steel) (closely related product name) | LID+LETIDMSSPIDTC |
| 2023 | JW-HD144N (closely related product name) | DHLID+LETIDMSSPANPID |
| 2024 | JW-HD144N (closely related product name) | DHLID+LETIDMSSPANPIDTC |
| 2021 | JW-HD144N-xxx (closely related product name) | LID+LETIDPID |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–10 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–10 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–10 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–8 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 980 | 11,766 | 6.08 |
| Palmdale | 1,835 | 1,073 | 12,882 | 6.69 |
| Chula Vista | 1,696 | 992 | 11,906 | 6.11 |
| Huntington Beach | 1,643 | 961 | 11,534 | 5.89 |
| Riverside | 1,696 | 992 | 11,906 | 6.21 |
| Santa Clarita | 1,724 | 1,009 | 12,102 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY JW-HD144N-R0 585 | 585 W | ≈22.7% | −0.320 | 52.7 | 14.01 | product 2025 | — |
| VSUN (Vietnam Sunergy) VSUN585N-144MH | 585 W | ≈22.7% | −0.309 | 52.25 | 13.88 | brand 6× (2021–2026) | 1 |
| Phono Solar PS585M8GFH-24/TNH | 585 W | ≈22.9% | −0.293 | 52.9 | 13.72 | product 2024, 2025 | 1 |
| Qcells Q.PEAK DUO XL-G11S.3/BFG 585 | 585 W | ≈21.5% | −0.348 | 53.57 | 13.72 | product 2024, 2025, 2026 | 1 |
Calculated from the panel area (2.58 m²): about 22.7% for the 585 W class. 585 W over 2.58 m² equals about 227 W per square meter.
PVWatts v8 with typical-year weather gives about 980 kWh per year per 585 W panel in Los Angeles and about 1,073 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.320 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 16.6% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 55.6 V, Vmp at 74 °C cell = 36.1 V). Final design must follow the inverter manual and NEC 690.7.
Yes. Rear gain depends on mounting height and ground reflectance.
JW-HD144N-R0-xxx was a PVEL Top Performer in 2025 (DH, HSS, LID+LETID, MSS, PAN, PID).