Cali-GrafCali-Graf
Solar panelJOLYWOOD (TAIZHOU) SOLAR TECHN…

JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY JW-HD132N 715

132 half-cut cells, bifacial. Power classes 705–730 W in the CEC list.

CEC listed · Feb 11, 2026UL 61730Bifacial
Power class
  • Power (STC)715 WCEC nameplate
  • Efficiency≈23.2%calculated from area
  • %/°C Pmax−0.360CEC listing test
  • PTC / STC94.5%PTC 676 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
JW-HD132N-705705 W48.8018.3640.7017.33≈22.9%666 WFeb 11, 2026
JW-HD132N-710710 W49.0018.4040.9017.36≈23.1%671 WFeb 11, 2026
JW-HD132N-715715 W49.2018.4441.1017.40≈23.2%676 WFeb 11, 2026
JW-HD132N-720720 W49.4018.4941.3017.44≈23.4%680 WFeb 11, 2026
JW-HD132N-725725 W49.6018.5341.5017.47≈23.5%685 WFeb 11, 2026
JW-HD132N-730730 W49.8018.5741.7017.51≈23.7%690 WFeb 11, 2026
≈ efficiency = Pmax ÷ CEC-listed area 3.08 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.360 %/°C
Voc coefficient β−0.310 %/°C
Isc coefficient α+0.055 %/°C
Operating cell temperatureNOCT 41.9 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
705 W524.5 W38.4 V × 13.66 A135.9 W96%
710 W528.4 W38.6 V × 13.69 A136.6 W96%
715 W532.3 W38.8 V × 13.72 A137.7 W96%
720 W536.2 W39 V × 13.75 A138.7 W96%
725 W540.2 W39.2 V × 13.78 A139.4 W96%
730 W544.1 W39.4 V × 13.81 A140.5 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026) · Clean Energy Council (Australia)
UL 61730IEC 61215:2021 / IEC 61730:2023

Independent reliability testing

Kiwa PVEL Scorecard
5
PVEL Scorecards
JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY named Top Performer, 2021–2026
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.7 V
Voc when cold
per panel
32.7 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,19811,9836.08
Palmdale1,8351,31213,1206.69
Chula Vista1,6961,21312,1266.11
Huntington Beach1,6431,17511,7475.89
Riverside1,6961,21312,1266.21
Santa Clarita1,7241,23312,3276.28
782Jan783Feb1,005Mar1,110Apr1,096May1,165Jun1,227Jul1,241Aug1,085Sep957Oct823Nov712DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 715 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY JW-HD132N 715715 W≈23.2%−0.36049.218.44brand 5×
Canadian Solar CS7N-715TB-AG715 W≈23%−0.28548.518.64product 2024
Phono Solar PS715M13GFH-22/WNH715 W≈23.2%−0.29149.218.22brand 9× (2016–2026)
Waaree BiN-03-710710 W≥22.9%−0.30248.4518.4brand 5× (2022–2026)
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY JW-HD132N 715?

Calculated from the panel area (3.08 m²): about 23.2% for the 715 W class. 715 W over 3.08 m² equals about 232 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,198 kWh per year per 715 W panel in Los Angeles and about 1,312 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.360 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.7 V, Vmp at 74 °C cell = 32.7 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY was named a Top Performer in 5 Scorecards (2021–2026).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — datasheet New N-type Bifacial Module TOPBiHiKu7 CS7N-725|730|735|740|745|750TB-AG.
  3. Waaree — datasheet ELITE SERIES BiN-03.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2021–2026.
  5. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  6. Clean Energy Council (Australia) — Approved PV modules list (as of Oct 8, 2026).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).