Cali-GrafCali-Graf
Solar panelJinkoSolar

JinkoSolar JKM380N-6RL3-V

132 half-cut cells. Power classes 365–400 W in the CEC list.

CEC listed · Jul 1, 2021UL 61730
Power class
  • Power (STC)380 WCEC nameplate
  • Efficiency≈20.5%calculated from area
  • %/°C Pmax−0.380CEC listing test
  • PTC / STC92.2%PTC 350 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 8 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
JKM365N-6RL3-V365 W43.9511.0335.7910.20≈19.7%336 WJul 1, 2021
JKM370N-6RL3-V370 W44.1411.1335.8610.32≈20.0%341 WJul 1, 2021
JKM375N-6RL3-V375 W44.3211.2335.9210.44≈20.3%345 WJul 1, 2021
JKM380N-6RL3-V380 W44.5111.3335.9910.56≈20.5%350 WJul 1, 2021
JKM385N-6RL3-V385 W44.6911.4336.0510.68≈20.8%355 WJul 1, 2021
JKM390N-6RL3-V390 W44.8811.5336.1110.80≈21.1%360 WJul 1, 2021
JKM395N-6RL3-V395 W45.0711.6336.1810.92≈21.4%364 WJul 1, 2021
JKM400N-6RL3-V400 W45.2511.7336.2411.04≈21.6%369 WJul 1, 2021
≈ efficiency = Pmax ÷ CEC-listed area 1.85 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.380 %/°C
Voc coefficient β−0.302 %/°C
Isc coefficient α+0.039 %/°C
Operating cell temperatureNOCT 46.6 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
365 W251.1 W33.31 V × 7.54 A68.8 W94%
370 W254.6 W33.37 V × 7.63 A69.8 W94%
375 W258 W33.43 V × 7.72 A70.7 W94%
380 W261.4 W33.49 V × 7.81 A71.7 W94%
385 W264.8 W33.55 V × 7.89 A72.6 W94%
390 W268.3 W33.61 V × 7.98 A73.5 W94%
395 W271.8 W33.67 V × 8.07 A74.5 W94%
400 W275.2 W33.73 V × 8.16 A75.4 W94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
12
PVEL Scorecards
JinkoSolar named Top Performer, 2014–2026
2023, 2025, 2026
RETC Overall Highest Achiever
JinkoSolar, manufacturer level
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — JinkoSolar

YearRecognition
2023Overall Highest Achiever; High Achievement in Performance (LeTID RESISTANCE); High Achievement in Quality (Hail durability test); High Achievement in Reliability (Pid resistance, SDML, Thermal cycle test)
2024High Achievement in Performance
2025Overall Highest Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Temperature coefficient, PAN file, Iam); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Tc, Sdml, Pid)

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
47.6 V
Voc when cold
per panel
28.6 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V47.6 / 28.6 V⚠ Works; below MPPT at peak heat1.31
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V47.6 / 28.6 V✗ Not a match: module voltage below MPPT range1
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V47.6 / 28.6 V✓ Within range0.49
Enphase IQ8M-72-2-US260–460 W60 V30–45 V47.6 / 28.6 V⚠ Works; below MPPT at peak heat1.17
Enphase IQ8A-72-2-US295–500 W60 V32–45 V47.6 / 28.6 V⚠ Works; below MPPT at peak heat1.09
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67663711,4646.08
Palmdale1,83569712,5516.69
Chula Vista1,69664411,6016.11
Huntington Beach1,64362411,2385.89
Riverside1,69664411,6016.21
Santa Clarita1,72465511,7926.28
748Jan749Feb961Mar1,062Apr1,049May1,114Jun1,174Jul1,187Aug1,038Sep916Oct787Nov681DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 380 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
JinkoSolar JKM380N-6RL3-V380 W≈20.5%−0.38044.5111.33brand 12×—
Qcells Q.PEAK DUO BLK ML-G10+ 380380 W≈19.4%−0.36245.1611.01product 2022, 2023221
JA Solar JAM54S31-385/MR385 W≈20.3%−0.32936.7113.52product 2023, 2024152
REC Group REC380AA Pure380 W≈21.2%−0.25648.410.17brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About JinkoSolar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

JKMxxxM-60HBL · 45JKMxxxN-54HL4-B · 10JKMxxxM-72HL-V · 6JKMxxxM-6RL3-B · 3JKMxxxM-72HL-TV · 3JKMxxxN-54HL4R-B · 1

Questions & answers

How efficient is the JinkoSolar JKM380N-6RL3-V?

Calculated from the panel area (1.85 m²): about 20.5% for the 380 W class. 380 W over 1.85 m² equals about 205 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 637 kWh per year per 380 W panel in Los Angeles and about 697 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.380 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.7% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–12 panels per string (Voc at 2 °C = 47.6 V, Vmp at 74 °C cell = 28.6 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 47.6 V vs max input 60 V; Vmp when hot 28.6 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; JinkoSolar was named a Top Performer in 12 Scorecards (2014–2026). RETC named JinkoSolar Overall Highest Achiever in 2023, 2025, 2026.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2014–2026.
  4. RETC — PV Module Index reports 2023–2026.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).