Cali-GrafCali-Graf
Solar panelJinkoSolar

JinkoSolar JKM320N-60H-MBB-B

120 half-cut cells. Power classes 315–330 W in the CEC list.

CEC listed · Feb 22, 2021UL 61730
Power class
  • Power (STC)320 WCEC nameplate
  • Efficiency≈19.6%calculated from area
  • %/°C Pmax−0.434CEC listing test
  • PTC / STC91.1%PTC 292 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 4 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
JKM315N-60H-MBB-B315 W39.8210.3432.929.57≈19.3%287 WFeb 22, 2021
JKM320N-60H-MBB-B320 W39.9510.4033.039.69≈19.6%292 WFeb 22, 2021
JKM325N-60H-MBB-B325 W40.0810.4633.139.81≈19.9%296 WFeb 22, 2021
JKM330N-60H-MBB-B330 W40.2110.5233.249.93≈20.2%301 WFeb 22, 2021
≈ efficiency = Pmax ÷ CEC-listed area 1.63 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.434 %/°C
Voc coefficient β−0.309 %/°C
Isc coefficient α+0.050 %/°C
Operating cell temperatureNOCT 46.1 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
315 W225.4 W29.86 V × 7.55 A59.1 W94%
320 W229 W29.96 V × 7.64 A60 W94%
325 W232.6 W30.05 V × 7.74 A60.9 W94%
330 W236.2 W30.15 V × 7.83 A61.9 W94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
12
PVEL Scorecards
JinkoSolar named Top Performer, 2014–2026
2023, 2025, 2026
RETC Overall Highest Achiever
JinkoSolar, manufacturer level
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — JinkoSolar

YearRecognition
2023Overall Highest Achiever; High Achievement in Performance (LeTID RESISTANCE); High Achievement in Quality (Hail durability test); High Achievement in Reliability (Pid resistance, SDML, Thermal cycle test)
2024High Achievement in Performance
2025Overall Highest Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Temperature coefficient, PAN file, Iam); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Tc, Sdml, Pid)

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
42.8 V
Voc when cold
per panel
25.2 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window10–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V42.8 / 25.2 V⚠ Works; below MPPT at peak heat1.1
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V42.8 / 25.2 V✗ Not a match: module voltage below MPPT range0.84
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V42.8 / 25.2 V⚠ Works; below MPPT at peak heat0.41
Enphase IQ8M-72-2-US260–460 W60 V30–45 V42.8 / 25.2 V⚠ Works; below MPPT at peak heat0.98
Enphase IQ8A-72-2-US295–500 W60 V32–45 V42.8 / 25.2 V⚠ Works; below MPPT at peak heat0.92
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67653611,7996.08
Palmdale1,83558712,9186.69
Chula Vista1,69654311,9406.11
Huntington Beach1,64352611,5675.89
Riverside1,69654311,9406.21
Santa Clarita1,72455212,1376.28
770Jan771Feb989Mar1,093Apr1,079May1,147Jun1,208Jul1,222Aug1,069Sep943Oct810Nov701DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 320 W panels

CEC PV Module List (Oct 7, 2026) · LG Electronics datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
JinkoSolar JKM320N-60H-MBB-B320 W≈19.6%−0.43439.9510.4brand 12×—
LG Electronics LG320N1C-N5320 W≈18.5%−0.34240.810.53product 20215
REC Group REC320NP320 W≈19.8%−0.35140.810.18brand 9× (2016–2025)4
Sinotec USA STS-320M3B-60320 W≈19.4%−0.37540.810.18—3
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About JinkoSolar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

JKMxxxM-60HBL · 45JKMxxxN-54HL4-B · 10JKMxxxM-72HL-V · 6JKMxxxM-6RL3-B · 3JKMxxxM-72HL-TV · 3JKMxxxN-54HL4R-B · 1

Questions & answers

How efficient is the JinkoSolar JKM320N-60H-MBB-B?

Calculated from the panel area (1.63 m²): about 19.6% for the 320 W class. 320 W over 1.63 m² equals about 196 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 536 kWh per year per 320 W panel in Los Angeles and about 587 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.434 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 22.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 42.8 V, Vmp at 74 °C cell = 25.2 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; JinkoSolar was named a Top Performer in 12 Scorecards (2014–2026). RETC named JinkoSolar Overall Highest Achiever in 2023, 2025, 2026.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. LG Electronics — datasheet Specification Sheet.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2014–2026.
  4. RETC — PV Module Index reports 2023–2026.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).