Cali-GrafCali-Graf
Solar panelJinkoSolar

JinkoSolar JKM345M-6TL3

120 half-cut cells. Power classes 330–365 W in the CEC list.

CEC listed · Dec 11, 2020UL 61730PVEL Top Performer 2022
Power class
  • Power (STC)345 WCEC nameplate
  • Efficiency≈20.5%calculated from area
  • %/°C Pmax−0.374CEC listing test
  • PTC / STC92.7%PTC 320 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 8 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
JKM330M-6TL3330 W39.3110.9232.6410.11≈19.6%306 WDec 11, 2020
JKM335M-6TL3335 W39.4111.0432.7510.23≈19.9%310 WDec 11, 2020
JKM340M-6TL3340 W39.5111.1632.8510.35≈20.2%315 WDec 11, 2020
JKM345M-6TL3345 W39.6111.2832.9510.47≈20.5%320 WDec 11, 2020
JKM350M-6TL3350 W39.7111.4033.0510.59≈20.8%325 WDec 11, 2020
JKM355M-6TL3355 W39.8111.5233.1510.71≈21.1%329 WDec 11, 2020
JKM360M-6TL3360 W39.9111.6433.2410.83≈21.4%334 WDec 11, 2020
JKM365M-6TL3365 W40.0111.7633.3410.95≈21.7%339 WDec 11, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.68 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.374 %/°C
Voc coefficient β−0.278 %/°C
Isc coefficient α+0.053 %/°C
Operating cell temperatureNOCT 45.4 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
330 W236.9 W30.54 V × 7.76 A61.8 W94%
335 W240.5 W30.64 V × 7.85 A62.7 W94%
340 W244.1 W30.74 V × 7.94 A63.6 W94%
345 W247.6 W30.83 V × 8.03 A64.6 W94%
350 W251.2 W30.93 V × 8.12 A65.5 W94%
355 W254.8 W31.02 V × 8.22 A66.4 W94%
360 W258.4 W31.1 V × 8.31 A67.4 W94%
365 W262.1 W31.2 V × 8.4 A68.3 W94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2022
PVEL Top Performer
this series
4
Tests passed as Top Performer
LID+LETID, MSS, PID, TC
12
PVEL Scorecards
JinkoSolar named Top Performer, 2014–2026
2023, 2025, 2026
RETC Overall Highest Achiever
JinkoSolar, manufacturer level

PVEL Top Performer tests

YearProductTests
2022JKMxxxM-6TL3LID+LETIDMSSPIDTC
2022JKMxxxM-6TL3-B (closely related product name)LID+LETIDMSSPIDTC

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — JinkoSolar

YearRecognition
2023Overall Highest Achiever; High Achievement in Performance (LeTID RESISTANCE); High Achievement in Quality (Hail durability test); High Achievement in Reliability (Pid resistance, SDML, Thermal cycle test)
2024High Achievement in Performance
2025Overall Highest Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Temperature coefficient, PAN file, Iam); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Tc, Sdml, Pid)

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
42.1 V
Voc when cold
per panel
26.1 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V42.1 / 26.1 V⚠ Works; below MPPT at peak heat1.19
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V42.1 / 26.1 V✗ Not a match: module voltage below MPPT range0.91
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V42.1 / 26.1 V⚠ Works; below MPPT at peak heat0.44
Enphase IQ8M-72-2-US260–460 W60 V30–45 V42.1 / 26.1 V⚠ Works; below MPPT at peak heat1.06
Enphase IQ8A-72-2-US295–500 W60 V32–45 V42.1 / 26.1 V⚠ Works; below MPPT at peak heat0.99
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67657811,5646.08
Palmdale1,83563312,6626.69
Chula Vista1,69658511,7026.11
Huntington Beach1,64356711,3375.89
Riverside1,69658511,7026.21
Santa Clarita1,72459511,8966.28
755Jan756Feb969Mar1,071Apr1,058May1,124Jun1,184Jul1,198Aug1,047Sep924Oct794Nov687DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 345 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · Qcells datasheet · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
JinkoSolar JKM345M-6TL3345 W≈20.5%−0.37439.6111.28product 2022—
LONGi LR4-60HPB-345M345 W≈19.5%−0.33940.211.06product 2021, 2022193
REC Group REC345AA345 W≈20.5%−0.27943.410.12brand 9× (2016–2025)30
Qcells Q.PEAK DUO-G8+ 345345 W≥19.3%−0.34340.4510.68product 202220
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About JinkoSolar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

JKMxxxM-60HBL · 45JKMxxxN-54HL4-B · 10JKMxxxM-72HL-V · 6JKMxxxM-6RL3-B · 3JKMxxxM-72HL-TV · 3JKMxxxN-54HL4R-B · 1

Questions & answers

How efficient is the JinkoSolar JKM345M-6TL3?

Calculated from the panel area (1.68 m²): about 20.5% for the 345 W class. 345 W over 1.68 m² equals about 205 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 578 kWh per year per 345 W panel in Los Angeles and about 633 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.374 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.4% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 42.1 V, Vmp at 74 °C cell = 26.1 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

JKMxxxM-6TL3 was a PVEL Top Performer in 2022 (LID+LETID, MSS, PID, TC).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.PEAK DUO-G8+ 345-360 EN ENDURING HIGH”.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2014–2026.
  4. RETC — PV Module Index reports 2023–2026.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).