132 half-cut cells, P-type PERC. Power classes 365–400 W in the CEC list.

CEC listed · Feb 22, 2021UL 6173012-yr product + 25-yr performance warrantyPVEL Top Performer 2022, 2023P-type PERCInstalled in 3 SoCal permits
Power class
  • Power (STC)375 WCEC nameplate
  • Efficiency≈19.6%calculated from area
  • %/°C Pmax−0.364CEC listing test
  • Degradation / yr0.55%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 8 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
JKM365M-6RL3-B365 W43.9210.7936.619.97≈19.1%337 WFeb 22, 2021
JKM370M-6RL3-B370 W44.0210.9036.7110.08≈19.4%342 WFeb 22, 2021
JKM375M-6RL3-B375 W44.1211.0136.8010.19≈19.6%346 WFeb 22, 2021
JKM380M-6RL3-B380 W44.2211.1236.9010.30≈19.9%351 WFeb 22, 2021
JKM385M-6RL3-B385 W44.3411.2237.0210.40≈20.2%356 WFeb 22, 2021
JKM390M-6RL3-B390 W44.4711.3237.1510.50≈20.4%361 WFeb 22, 2021
JKM395M-6RL3-B395 W44.5911.4237.2710.60≈20.7%366 WFeb 22, 2021
JKM400M-6RL3-B400 W44.7111.5237.3910.70≈21.0%370 WFeb 22, 2021
≈ efficiency = Pmax ÷ panel area 1.909 m² (datasheet size).

Build & dimensions

JinkoSolar datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · JinkoSolar datasheet · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ—−0.364 %/°C
Voc coefficient β−0.28 %/°C−0.300 %/°C
Isc coefficient α+0.05 %/°C+0.047 %/°C
Vmp coefficient≈ −0.41 %/°C—
Operating cell temperatureNMOT 40.5 °CNOCT 46.7 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
365 W255.6 W33.44 V × 7.64 A69.6 W95%
370 W259.1 W33.53 V × 7.73 A70.5 W95%
375 W262.6 W33.62 V × 7.81 A71.5 W95%
380 W266.1 W33.71 V × 7.89 A72.4 W95%
385 W269.6 W33.82 V × 7.97 A73.4 W95%
390 W273.1 W33.94 V × 8.05 A74.3 W95%
395 W276.6 W34.05 V × 8.12 A75.3 W95%
400 W280.1 W34.16 V × 8.2 A76.3 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

JinkoSolar datasheet
Packaging: 60 per pallet · 744 per container

Certifications

CEC PV Module List (Oct 7, 2026) · JinkoSolar datasheet
UL 61730UL 1703IEC 61215IEC 61730Fire rating Type 10 (UL 61730)ISO 14001ISO 45001ISO 9001

Warranty & degradation

JinkoSolar datasheet

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2022, 2023
PVEL Top Performer
this series
5
Tests passed as Top Performer
DH, LID+LETID, MSS, PID, TC
12
PVEL Scorecards
JinkoSolar named Top Performer, 2014–2026
2023, 2025, 2026
RETC Overall Highest Achiever
JinkoSolar, manufacturer level

PVEL Top Performer tests

YearProductTests
2022JKMxxxM-6RL3-BLID+LETIDMSSPIDTC
2023JKMxxxM-6RL3-BDH
2022JKMxxxM-6RL3 (closely related product name)LID+LETIDMSSPIDTC
2023JKMxxxM-6RL3 (closely related product name)DH

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — JinkoSolar

YearRecognition
2023Overall Highest Achiever; High Achievement in Performance (LeTID RESISTANCE); High Achievement in Quality (Hail durability test); High Achievement in Reliability (Pid resistance, SDML, Thermal cycle test)
2024High Achievement in Performance
2025Overall Highest Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Temperature coefficient, PAN file, Iam); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Tc, Sdml, Pid)

Inverter compatibility & string sizing

JinkoSolar datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
47 V
Voc when cold
per panel
29.4 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V47 / 29.4 V✓ Within range1.29
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V47 / 29.4 V✗ Not a match: module voltage below MPPT range0.99
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V47 / 29.4 V✓ Within range0.48
Enphase IQ8M-72-2-US260–460 W60 V30–45 V47 / 29.4 V⚠ Works; below MPPT at peak heat1.15
Enphase IQ8A-72-2-US295–500 W60 V32–45 V47 / 29.4 V⚠ Works; below MPPT at peak heat1.07
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67662811,9426.08
Palmdale1,83568813,0746.69
Chula Vista1,69663612,0846.11
Huntington Beach1,64361611,7065.89
Riverside1,69663612,0846.21
Santa Clarita1,72464612,2846.28
779Jan780Feb1,001Mar1,106Apr1,092May1,161Jun1,223Jul1,237Aug1,082Sep954Oct820Nov710DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs JKMxxxM-6RL3-B panels in SoCal

building permits
3
Permits naming this series
Jul 2021 – Feb 2022
1
Jurisdictions so far
LA County (unincorp.) (3)
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Compare with similar 375 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
JinkoSolar JKM375M-6RL3-B375 W≈19.6%−0.36444.1211.01product 2022, 20233
Qcells Q.PEAK DUO BLK ML-G10+ 380380 W≈19.4%−0.36245.1611.01product 2022, 2023221
LONGi LR4-60HPB-370M370 W≈20.9%−0.33941.211.5product 2021, 2022193
REC Group REC380AA Pure380 W≈21.2%−0.25648.410.17brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

About JinkoSolar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

JKMxxxM-60HBL · 45JKMxxxN-54HL4-B · 10JKMxxxM-72HL-V · 6JKMxxxM-72HL-TV · 3JKMxxxN-54HL4R-B · 1JKMxxxM-72HBL-V · 1

Questions & answers

How efficient is the JinkoSolar JKM375M-6RL3-B?

Calculated from the panel area (1.91 m²): about 19.6% for the 375 W class. 375 W over 1.91 m² equals about 196 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 628 kWh per year per 375 W panel in Los Angeles and about 688 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.364 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.8% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–12 panels per string (Voc at 2 °C = 47 V, Vmp at 74 °C cell = 29.4 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 47 V vs max input 60 V; Vmp when hot 29.4 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

What does the warranty cover?

12 years on the product and 25 years linear on performance (manufacturer datasheet).

How big and heavy is it?

73 × 40.5 × 1.38 in (1,855 × 1,029 × 35 mm), 47.4 lb (21.5 kg).

Has this panel been reliability-tested?

JKMxxxM-6RL3-B was a PVEL Top Performer in 2022, 2023 (DH, LID+LETID, MSS, PID, TC).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR PRODUCT.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  4. JinkoSolar — document library on the manufacturer’s website (links above).
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2014–2026.
  6. RETC — PV Module Index reports 2023–2026.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Jul 2021 – Feb 2022). Equipment matched from permit descriptions by model number.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).