132 half-cut cells, P-type PERC. Power classes 365–400 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| JKM365M-6RL3-B | 365 W | 43.92 | 10.79 | 36.61 | 9.97 | ≈19.1% | 337 W | Feb 22, 2021 |
| JKM370M-6RL3-B | 370 W | 44.02 | 10.90 | 36.71 | 10.08 | ≈19.4% | 342 W | Feb 22, 2021 |
| JKM375M-6RL3-B | 375 W | 44.12 | 11.01 | 36.80 | 10.19 | ≈19.6% | 346 W | Feb 22, 2021 |
| JKM380M-6RL3-B | 380 W | 44.22 | 11.12 | 36.90 | 10.30 | ≈19.9% | 351 W | Feb 22, 2021 |
| JKM385M-6RL3-B | 385 W | 44.34 | 11.22 | 37.02 | 10.40 | ≈20.2% | 356 W | Feb 22, 2021 |
| JKM390M-6RL3-B | 390 W | 44.47 | 11.32 | 37.15 | 10.50 | ≈20.4% | 361 W | Feb 22, 2021 |
| JKM395M-6RL3-B | 395 W | 44.59 | 11.42 | 37.27 | 10.60 | ≈20.7% | 366 W | Feb 22, 2021 |
| JKM400M-6RL3-B | 400 W | 44.71 | 11.52 | 37.39 | 10.70 | ≈21.0% | 370 W | Feb 22, 2021 |
| Datasheet | CEC listing test | |
|---|---|---|
| Pmax coefficient γ | — | −0.364 %/°C |
| Voc coefficient β | −0.28 %/°C | −0.300 %/°C |
| Isc coefficient α | +0.05 %/°C | +0.047 %/°C |
| Vmp coefficient | ≈ −0.41 %/°C | — |
| Operating cell temperature | NMOT 40.5 °C | NOCT 46.7 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 365 W | 255.6 W | 33.44 V × 7.64 A | 69.6 W | 95% |
| 370 W | 259.1 W | 33.53 V × 7.73 A | 70.5 W | 95% |
| 375 W | 262.6 W | 33.62 V × 7.81 A | 71.5 W | 95% |
| 380 W | 266.1 W | 33.71 V × 7.89 A | 72.4 W | 95% |
| 385 W | 269.6 W | 33.82 V × 7.97 A | 73.4 W | 95% |
| 390 W | 273.1 W | 33.94 V × 8.05 A | 74.3 W | 95% |
| 395 W | 276.6 W | 34.05 V × 8.12 A | 75.3 W | 95% |
| 400 W | 280.1 W | 34.16 V × 8.2 A | 76.3 W | 95% |
| Year | Product | Tests |
|---|---|---|
| 2022 | JKMxxxM-6RL3-B | LID+LETIDMSSPIDTC |
| 2023 | JKMxxxM-6RL3-B | DH |
| 2022 | JKMxxxM-6RL3 (closely related product name) | LID+LETIDMSSPIDTC |
| 2023 | JKMxxxM-6RL3 (closely related product name) | DH |
| Year | Recognition |
|---|---|
| 2023 | Overall Highest Achiever; High Achievement in Performance (LeTID RESISTANCE); High Achievement in Quality (Hail durability test); High Achievement in Reliability (Pid resistance, SDML, Thermal cycle test) |
| 2024 | High Achievement in Performance |
| 2025 | Overall Highest Achiever |
| 2026 | Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Temperature coefficient, PAN file, Iam); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Tc, Sdml, Pid) |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–12 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–12 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–12 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 8–10 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 47 / 29.4 V | ✓ Within range | 1.29 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 47 / 29.4 V | ✗ Not a match: module voltage below MPPT range | 0.99 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 47 / 29.4 V | ✓ Within range | 0.48 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 47 / 29.4 V | ⚠ Works; below MPPT at peak heat | 1.15 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 47 / 29.4 V | ⚠ Works; below MPPT at peak heat | 1.07 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 628 | 11,942 | 6.08 |
| Palmdale | 1,835 | 688 | 13,074 | 6.69 |
| Chula Vista | 1,696 | 636 | 12,084 | 6.11 |
| Huntington Beach | 1,643 | 616 | 11,706 | 5.89 |
| Riverside | 1,696 | 636 | 12,084 | 6.21 |
| Santa Clarita | 1,724 | 646 | 12,284 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| JinkoSolar JKM375M-6RL3-B | 375 W | ≈19.6% | −0.364 | 44.12 | 11.01 | product 2022, 2023 | 3 |
| Qcells Q.PEAK DUO BLK ML-G10+ 380 | 380 W | ≈19.4% | −0.362 | 45.16 | 11.01 | product 2022, 2023 | 221 |
| LONGi LR4-60HPB-370M | 370 W | ≈20.9% | −0.339 | 41.2 | 11.5 | product 2021, 2022 | 193 |
| REC Group REC380AA Pure | 380 W | ≈21.2% | −0.256 | 48.4 | 10.17 | brand 9× (2016–2025) | 66 |
Calculated from the panel area (1.91 m²): about 19.6% for the 375 W class. 375 W over 1.91 m² equals about 196 W per square meter.
PVWatts v8 with typical-year weather gives about 628 kWh per year per 375 W panel in Los Angeles and about 688 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.364 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.8% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–12 panels per string (Voc at 2 °C = 47 V, Vmp at 74 °C cell = 29.4 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the Enphase datasheet: Voc when cold 47 V vs max input 60 V; Vmp when hot 29.4 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.
12 years on the product and 25 years linear on performance (manufacturer datasheet).
73 × 40.5 × 1.38 in (1,855 × 1,029 × 35 mm), 47.4 lb (21.5 kg).
JKMxxxM-6RL3-B was a PVEL Top Performer in 2022, 2023 (DH, LID+LETID, MSS, PID, TC).