Cali-GrafCali-Graf
Solar panelJinkoSolar

JinkoSolar JKM440M-60HL4-V

120 half-cut cells. Power classes 420–460 W in the CEC list.

CEC listed · Apr 1, 2021UL 61730PVEL Top Performer 2024
Power class
  • Power (STC)440 WCEC nameplate
  • Efficiency≈21.1%calculated from area
  • %/°C Pmax−0.397CEC listing test
  • PTC / STC91.9%PTC 404 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 9 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
JKM420M-60HL4-V420 W40.7013.4933.3112.61≈20.1%385 WApr 1, 2021
JKM425M-60HL4-V425 W40.7813.5533.4212.72≈20.3%390 WApr 1, 2021
JKM430M-60HL4-V430 W40.8613.6133.5212.83≈20.6%395 WApr 1, 2021
JKM435M-60HL4-V435 W40.9413.6733.6212.94≈20.8%400 WApr 1, 2021
JKM440M-60HL4-V440 W41.0213.7333.7213.05≈21.1%404 WApr 1, 2021
JKM445M-60HL4-V445 W41.1013.7933.8213.16≈21.3%409 WApr 1, 2021
JKM450M-60HL4-V450 W41.1813.8533.9113.27≈21.5%414 WApr 1, 2021
JKM455M-60HL4-V455 W41.3313.9334.0613.36≈21.8%419 WApr 1, 2021
JKM460M-60HL4-V460 W41.4814.0134.2013.45≈22.0%423 WApr 1, 2021
≈ efficiency = Pmax ÷ CEC-listed area 2.09 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.397 %/°C
Voc coefficient β−0.304 %/°C
Isc coefficient α+0.050 %/°C
Operating cell temperatureNOCT 46.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
420 W295.9 W30.64 V × 9.65 A81.2 W97%
425 W299.4 W30.74 V × 9.74 A82.1 W97%
430 W302.9 W30.84 V × 9.82 A83.1 W97%
435 W306.4 W30.93 V × 9.91 A84.1 W97%
440 W309.9 W31.02 V × 9.99 A85 W97%
445 W313.5 W31.11 V × 10.08 A86 W97%
450 W316.9 W31.2 V × 10.16 A86.9 W97%
455 W320.5 W31.33 V × 10.23 A87.9 W97%
460 W324 W31.46 V × 10.3 A88.9 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2024
PVEL Top Performer
this series
1
Tests passed as Top Performer
MSS
12
PVEL Scorecards
JinkoSolar named Top Performer, 2014–2026
2023, 2025, 2026
RETC Overall Highest Achiever
JinkoSolar, manufacturer level

PVEL Top Performer tests

YearProductTests
2024JKMxxxM-60HL4-VMSS

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — JinkoSolar

YearRecognition
2023Overall Highest Achiever; High Achievement in Performance (LeTID RESISTANCE); High Achievement in Quality (Hail durability test); High Achievement in Reliability (Pid resistance, SDML, Thermal cycle test)
2024High Achievement in Performance
2025Overall Highest Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Temperature coefficient, PAN file, Iam); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Tc, Sdml, Pid)

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.9 V
Voc when cold
per panel
26.3 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.9 / 26.3 V⚠ Works; below MPPT at peak heat1.52
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.9 / 26.3 V✗ Not a match: module voltage below MPPT range1.16
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.9 / 26.3 V⚠ Works; below MPPT at peak heat0.56
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.9 / 26.3 V⚠ Works; below MPPT at peak heat1.35
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.9 / 26.3 V⚠ Works; below MPPT at peak heat1.26
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67673711,7996.08
Palmdale1,83580712,9186.69
Chula Vista1,69674611,9406.11
Huntington Beach1,64372311,5675.89
Riverside1,69674611,9406.21
Santa Clarita1,72475912,1376.28
770Jan771Feb989Mar1,093Apr1,079May1,147Jun1,208Jul1,222Aug1,069Sep943Oct810Nov701DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 440 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)SoCal permits (series)
JinkoSolar JKM440M-60HL4-V440 W≈21.1%−0.39741.0213.73—product 2024—
Qcells Q.TRON BLK M-G2+ 440440 W≥22.5%−0.27639.8813.925 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-440QD440 W≈22.6%−0.29438.9714.2525 / 30 yrbrand 7× (2017–2025)39
Hyundai Energy Solutions HiN-T440NF(BK)440 W≈22.7%−0.29838.814.3925 / 30 yrbrand 5× (2017–2025)37
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About JinkoSolar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

JKMxxxM-60HBL · 45JKMxxxN-54HL4-B · 10JKMxxxM-72HL-V · 6JKMxxxM-6RL3-B · 3JKMxxxM-72HL-TV · 3JKMxxxN-54HL4R-B · 1

Questions & answers

How efficient is the JinkoSolar JKM440M-60HL4-V?

Calculated from the panel area (2.09 m²): about 21.1% for the 440 W class. 440 W over 2.09 m² equals about 211 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 737 kWh per year per 440 W panel in Los Angeles and about 807 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.397 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.9 V, Vmp at 74 °C cell = 26.3 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

JKMxxxM-60HL4-V was a PVEL Top Performer in 2024 (MSS).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  3. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  4. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2014–2026.
  6. RETC — PV Module Index reports 2023–2026.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).