JinkoSolar JKM325M-60HBL

120 half-cut cells, PERC. Power classes 310–345 W in the CEC list.

CEC listed · Nov 15, 2018UL 170310-yr product + 25-yr performance warrantyPERCInstalled in 45 SoCal permits
Power class
  • Power (STC)325 Wtolerance +3 / −0 %
  • Efficiency≈19.3%calculated from area
  • %/°C Pmax−0.36CEC test: −0.407
  • Performance warranty25 yrdatasheet

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 8 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
JKM310M-60HBL310 W40.509.9233.009.40≈18.4%285 WNov 15, 2018
JKM315M-60HBL315 W40.7010.0433.209.49≈18.7%289 WNov 15, 2018
JKM320M-60HBL320 W40.9010.1533.409.59≈19.0%294 WNov 15, 2018
JKM325M-60HBL325 W41.1010.2033.609.68≈19.3%299 WNov 15, 2018
JKM330M-60HBL330 W40.6010.6133.549.84≈19.6%304 WNov 15, 2018
JKM335M-60HBL335 W40.8010.7333.749.93≈19.9%308 WNov 15, 2018
JKM340M-60HBL340 W41.0010.8233.9310.02≈20.1%313 WNov 15, 2018
JKM345M-60HBL345 W41.2010.9134.1210.11≈20.4%318 WJan 21, 2020
≈ efficiency = Pmax ÷ panel area 1.687 m² (datasheet size).

Build & dimensions

JinkoSolar datasheet · Cali-Graf calculation

Heat & cold behaviour

JinkoSolar datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.36 %/°C−0.407 %/°C
Voc coefficient β−0.28 %/°C−0.317 %/°C
Isc coefficient α+0.05 %/°C+0.050 %/°C
Vmp coefficient—−0.428 %/°C
Operating cell temperatureNMOT 45 ± 2 °CNOCT 45.5 °C

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
310 W225.9 W30.13 V × 7.5 A58.2 W94%
315 W229.4 W30.31 V × 7.57 A59.2 W94%
320 W233.3 W30.5 V × 7.65 A60.1 W94%
325 W236.8 W30.68 V × 7.72 A61.1 W94%
330 W241.8 W31.72 V × 7.62 A62.6 W95%
335 W245.4 W31.91 V × 7.69 A63.6 W95%
340 W249.1 W32.09 V × 7.76 A64.5 W95%
345 W252.7 W32.27 V × 7.83 A65.5 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

JinkoSolar datasheet
Packaging: 31 per pallet · 806 per container

Certifications

CEC PV Module List (Oct 7, 2026) · JinkoSolar datasheet
UL 1703IEC 61215IEC 61730Fire rating Type 1 (UL 61730)ISO 14001ISO 45001ISO 9001

Warranty & degradation

JinkoSolar datasheets

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
12
PVEL Scorecards
JinkoSolar named Top Performer, 2014–2026
2023, 2025, 2026
RETC Overall Highest Achiever
JinkoSolar, manufacturer level
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — JinkoSolar

YearRecognition
2023Overall Highest Achiever; High Achievement in Performance (LeTID RESISTANCE); High Achievement in Quality (Hail durability test); High Achievement in Reliability (Pid resistance, SDML, Thermal cycle test)
2024High Achievement in Performance
2025Overall Highest Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Temperature coefficient, PAN file, Iam); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Tc, Sdml, Pid)

Inverter compatibility & string sizing

JinkoSolar datasheet · CEC PV Module List (Oct 7, 2026) · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.7 V
Voc when cold
per panel
26.6 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.7 / 26.6 V⚠ Works; below MPPT at peak heat1.12
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.7 / 26.6 V✗ Not a match: module voltage below MPPT range0.86
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.7 / 26.6 V⚠ Works; below MPPT at peak heat0.42
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.7 / 26.6 V⚠ Works; below MPPT at peak heat1
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.7 / 26.6 V⚠ Works; below MPPT at peak heat0.93
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67654511,9836.08
Palmdale1,83559613,1206.69
Chula Vista1,69655112,1266.11
Huntington Beach1,64353411,7475.89
Riverside1,69655112,1266.21
Santa Clarita1,72456012,3276.28
782Jan783Feb1,005Mar1,110Apr1,096May1,165Jun1,227Jul1,241Aug1,085Sep957Oct823Nov712DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs JKMxxxM-60HBL panels in SoCal

building permits · CSLB License Master
45
Permits naming this series
Apr 2020 – Sep 2022
1
Licensed installers
CSLB license on the permit
2
Jurisdictions so far
LA County (unincorp.) (44), Los Angeles (1)

Permits over time

10Q2 ’205Q3 ’201Q4 ’205Q1 ’2114Q2 ’214Q3 ’214Q4 ’211Q1 ’220Q2 ’221Q3 ’22permits per quarter

Power class named in permit

325 W
32
320 W
13

Top ZIP codes

  • ZIP 9100116
  • ZIP 912147
  • ZIP 906064
  • ZIP 902212
  • ZIP 917242
  • Other ZIP codes14

Typical system

median 5.8 kW, 18 panels (n = 33)

Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Installed together with

building permits

Inverters

SolarEdge SE…H (HD-Wave)
42

Optimizers

SolarEdge Power Optimizer
44

Batteries

LG Energy Solution RESU 10H
3
Number of permits naming both this panel series and the product; 45 of 45 permits list other equipment.

Compare with similar 325 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizeWarrantyPVEL (product / brand)SoCal permits (series)
JinkoSolar JKM325M-60HBL325 W≈19.3%−0.40741.110.266.3 × 39.4 in10 / 25 yrbrand 12×45
Qcells Q.PEAK DUO-G8+ 330330 W≈18.4%−0.34339.7110.5268.5 × 40.6 in25 / 25 yrproduct 202220
LG Electronics LG325N1C-N5325 W≈18.8%−0.34240.910.5766.9 × 40 in25 / 25 yrproduct 20215
REC Group REC325TP3M325 W≈20.2%−0.33639.510.36——brand 9× (2016–2025)4
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

About JinkoSolar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

JKMxxxN-54HL4-B · 10JKMxxxM-72HL-V · 6JKMxxxM-6RL3-B · 3JKMxxxM-72HL-TV · 3JKMxxxN-54HL4R-B · 1JKMxxxM-72HBL-V · 1

Questions & answers

How efficient is the JinkoSolar JKM325M-60HBL?

Calculated from the panel area (1.69 m²): about 19.3% for the 325 W class. 325 W over 1.69 m² equals about 193 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 545 kWh per year per 325 W panel in Los Angeles and about 596 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.36 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.7 V, Vmp at 74 °C cell = 26.6 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

10 years on the product and 25 years on performance (manufacturer datasheet).

How big and heavy is it?

66.3 × 39.4 × 1.38 in (1,684 × 1,002 × 35 mm), 41.9 lb (19 kg).

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; JinkoSolar was named a Top Performer in 12 Scorecards (2014–2026). RETC named JinkoSolar Overall Highest Achiever in 2023, 2025, 2026.

What fire rating does it have?

UL 61730 fire rating Type 1 per datasheet.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Qcells — manufacturer datasheet “Q.PEAK DUO-G8+ 345-360 EN ENDURING HIGH”.
  5. LG Electronics — datasheet Specification Sheet.
  6. JinkoSolar — document library on the manufacturer’s website (links above).
  7. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2014–2026.
  8. RETC — PV Module Index reports 2023–2026.
  9. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  10. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  11. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  12. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Apr 2020 – Sep 2022); LADBS, City of Los Angeles (Jul 2020). Equipment matched from permit descriptions by model number.
  13. Contractors State License Board — License Master (contractor names and license status), as of Oct 5, 2026.
  14. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).