Jiangsu Runergy New Energy Technology HY-DH156N8 610

156 half-cut cells, bifacial, white backsheet. Power classes 595–630 W in the CEC list.

CEC listed · Feb 12, 2024UL 61730Bifacial
Power class
  • Power (STC)610 WCEC nameplate
  • Efficiency≈21.8%calculated from area
  • %/°C Pmax−0.299CEC listing test
  • PTC / STC94.9%PTC 579 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 8 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
HY-DH156N8-595595 W54.5714.0344.9913.23≈21.2%564 WFeb 12, 2024
HY-DH156N8-600600 W54.7614.0945.2013.28≈21.4%569 WFeb 12, 2024
HY-DH156N8-605605 W54.9214.1545.3913.33≈21.6%574 WFeb 12, 2024
HY-DH156N8-610610 W55.1014.2145.6013.38≈21.8%579 WFeb 12, 2024
HY-DH156N8-615615 W55.2614.2745.7613.44≈22.0%584 WFeb 12, 2024
HY-DH156N8-620620 W55.4714.3345.9213.51≈22.1%588 WFeb 12, 2024
HY-DH156N8-625625 W55.6314.3946.0513.58≈22.3%593 WFeb 12, 2024
HY-DH156N8-630630 W55.7914.4546.1813.65≈22.5%598 WFeb 12, 2024
≈ efficiency = Pmax ÷ CEC-listed area 2.8 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.299 %/°C
Voc coefficient β−0.230 %/°C
Isc coefficient α+0.044 %/°C
Operating cell temperatureNOCT 43.3 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
595 W428.8 W42.34 V × 10.13 A108.1 W91%
600 W432.4 W42.54 V × 10.17 A109 W91%
605 W435.9 W42.72 V × 10.2 A109.9 W91%
610 W439.6 W42.92 V × 10.24 A110.8 W91%
615 W443.1 W43.07 V × 10.29 A111.7 W91%
620 W446.9 W43.22 V × 10.34 A112.7 W91%
625 W450.5 W43.34 V × 10.4 A113.6 W91%
630 W454.1 W43.46 V × 10.45 A114.5 W91%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026) · Clean Energy Council (Australia)
UL 61730IEC 61215:2021 / IEC 61730:2023

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2025
PVEL Top Performer
closely related product name
3
Tests passed as Top Performer
DH, MSS, TC
2
PVEL Scorecards
Jiangsu Runergy New Energy Technology named Top Performer, 2024–2025
2023, 2024, 2025, 2026
RETC Overall Highest Achiever
Jiangsu Runergy New Energy Technology, manufacturer level

PVEL Top Performer tests

YearProductTests
2025HY-DH156N8-xxxW (closely related product name)DHMSSTC

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — Jiangsu Runergy New Energy Technology

YearRecognition
2023Overall Highest Achiever; High Achievement in Performance (LeTID RESISTANCE, Pan file performance); High Achievement in Quality (Thresher test); High Achievement in Reliability (Damp heat test, Pid resistance, SDML, Thermal cycle test)
2024Overall Highest Achiever
2025Overall Highest Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Iam, Letid, Lid, PAN file, Temperature coefficient); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Pid, Sdml, Tc, Uvid)

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
58 V
Voc when cold
per panel
37.9 V
Vmp when hot
per panel
10
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–10
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–10
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–10
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–8

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,02211,2466.08
Palmdale1,8351,11912,3136.69
Chula Vista1,6961,03511,3806.11
Huntington Beach1,6431,00211,0255.89
Riverside1,6961,03511,3806.21
Santa Clarita1,7241,05211,5686.28
734Jan735Feb943Mar1,041Apr1,029May1,093Jun1,151Jul1,165Aug1,019Sep898Oct772Nov668DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 610 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · Canadian Solar datasheet
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
Jiangsu Runergy New Energy Technology HY-DH156N8 610610 W≈21.8%−0.29955.114.21brand 2×
Phono Solar PS610M8GFH-24/TNH610 W≈23.8%−0.29353.814.02product 2024, 2025
ZNShine Solar ZXM7-UHLDD144-610/N610 W≈23.8%−0.28152.714.66product 2024, 2025, 2026
Canadian Solar CS6.2-66TB-610HP610 W≈22.6%−0.2824815.97brand 5× (2020–2026)
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Jiangsu Runergy New Energy Technology

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

HY-DH108P8B · 2HY-DH144N8HY-DH144N8BHY-DH96N11HY-DH96N11BHY-DH108N8

Questions & answers

How efficient is the Jiangsu Runergy New Energy Technology HY-DH156N8 610?

Calculated from the panel area (2.8 m²): about 21.8% for the 610 W class. 610 W over 2.8 m² equals about 218 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,022 kWh per year per 610 W panel in Los Angeles and about 1,119 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.299 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 58 V, Vmp at 74 °C cell = 37.9 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

HY-DH156N8-xxxW was a PVEL Top Performer in 2025 (DH, MSS, TC) — a closely related product name.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — datasheet TOPBiHiKu6 Anti-Hail N-type Bifacial TOPCon Technology.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2024–2025.
  4. RETC — PV Module Index reports 2023–2026.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. Clean Energy Council (Australia) — Approved PV modules list (as of Oct 8, 2026).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).