Cali-GrafCali-Graf
Building-integrated solar panelJackery

Jackery JS-42A

16 cells. Power classes 36–45 W in the CEC list.

CEC listed · Jun 23, 2025UL 61730Building-integrated (BIPV)
Power class
  • Power (STC)42 WCEC nameplate
  • Efficiency≈14.3%calculated from area
  • %/°C Pmax−0.379CEC listing test
  • PTC / STC92.4%PTC 39 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 4 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
JS-36A36 W5.548.854.537.95≈12.3%33 WJun 23, 2025
JS-38A38 W5.549.144.538.38≈13.0%35 WJun 23, 2025
JS-42A42 W5.5410.324.539.56≈14.3%39 WJun 23, 2025
JS-45A45 W5.5410.364.539.93≈15.4%42 WJun 23, 2025
≈ efficiency = Pmax ÷ CEC-listed area 0.29 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.379 %/°C
Voc coefficient β−0.260 %/°C
Isc coefficient α+0.037 %/°C
Operating cell temperatureNOCT 44.1 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
36 W36 W4.37 V × 8.24 A——
38 W37.9 W4.37 V × 8.69 A——
42 W38.8 W4.32 V × 8.99 A——
45 W40.3 W4.32 V × 9.34 A——
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8
5.9 V
Voc when cold
per panel
3.6 V
Vmp when hot
per panel
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
Integrated roof products are wired per the manufacturer’s system design.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6767011,7556.08
Palmdale1,8357712,8716.69
Chula Vista1,6967111,8966.11
Huntington Beach1,6436911,5245.89
Riverside1,6967111,8966.21
Santa Clarita1,7247212,0926.28
767Jan768Feb985Mar1,089Apr1,075May1,143Jun1,204Jul1,218Aug1,065Sep939Oct807Nov699DeckWh per month · Los Angeles
PVWatts models a standard roof-mounted module; integrated roof products are not modeled separately.
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Questions & answers

How efficient is the Jackery JS-42A?

Calculated from the panel area (0.29 m²): about 14.3% for the 42 W class. 42 W over 0.29 m² equals about 143 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 70 kWh per year per 42 W panel in Los Angeles and about 77 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.379 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.6% below the STC rating.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List (snapshot Oct 7, 2026).
  2. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  3. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).