Cali-GrafCali-Graf
Solar panelJA Solar

JA Solar JAM66D45-615/LB

132 cells, bifacial. Power classes 595–635 W in the CEC list.

CEC listed · Mar 3, 2025UL 61730BifacialPVEL Top Performer 2025, 2026
Power class
  • Power (STC)615 WCEC nameplate
  • Efficiency≈23.3%calculated from area
  • %/°C Pmax−0.317CEC listing test
  • PTC / STC94%PTC 578 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 9 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
JAM66D45-595/LB595 W47.5015.9039.2715.15≈22.5%559 WMar 3, 2025
JAM66D45-600/LB600 W47.7015.9539.4415.21≈22.7%563 WMar 3, 2025
JAM66D45-605/LB605 W47.9016.0039.6015.28≈22.9%568 WMar 3, 2025
JAM66D45-610/LB610 W48.1016.0539.7715.34≈23.1%573 WMar 3, 2025
JAM66D45-615/LB615 W48.3016.1039.9615.39≈23.3%578 WMar 3, 2025
JAM66D45-620/LB620 W48.5016.1340.2115.42≈23.5%583 WMar 3, 2025
JAM66D45-625/LB625 W48.7016.1540.4515.45≈23.7%588 WMar 11, 2026
JAM66D45-630/LB630 W48.9016.1840.7015.48≈23.9%592 WMar 11, 2026
JAM66D45-635/LB635 W49.1016.2140.9415.51≈24.1%597 WMar 11, 2026
≈ efficiency = Pmax ÷ CEC-listed area 2.64 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.317 %/°C
Voc coefficient β−0.247 %/°C
Isc coefficient α+0.041 %/°C
Operating cell temperatureNOCT 46 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
595 W444.7 W38.12 V × 11.67 A115.1 W97%
600 W448.4 W38.28 V × 11.71 A116 W97%
605 W452.3 W38.44 V × 11.77 A117 W97%
610 W456 W38.6 V × 11.81 A118 W97%
615 W459.7 W38.79 V × 11.85 A118.9 W97%
620 W463.5 W39.03 V × 11.87 A119.9 W97%
625 W467.1 W39.26 V × 11.9 A120.9 W97%
630 W470.9 W39.51 V × 11.92 A121.9 W97%
635 W474.6 W39.74 V × 11.94 A122.8 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026) · Clean Energy Council (Australia)
UL 61730IEC 61215:2021 / IEC 61730:2023

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2025, 2026
PVEL Top Performer
this series
5
Tests passed as Top Performer
DH, LID+LETID, MSS, PID, TC
11
PVEL Scorecards
JA Solar named Top Performer, 2014–2026
2023, 2024, 2025, 2026
RETC Overall Highest Achiever
JA Solar, manufacturer level

PVEL Top Performer tests

YearProductTests
2025JAM66D45-xxx/LBDHLID+LETIDMSSPIDTC
2026JAM66D45-xxx/LBDHLID+LETIDMSSPIDTC

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — JA Solar

YearRecognition
2023Overall Highest Achiever; High Achievement in Performance (Ptc-to-stc ratio, Pan file performance, Module efficiency, LeTID RESISTANCE); High Achievement in Quality (Hail durability test, Thresher test); High Achievement in Reliability (Thermal cycle test, SDML, Pid resistance, Damp heat test)
2024Overall Highest Achiever
2025Overall Highest Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Conversion efficiency, Iam, Letid, Lid, PAN file, PTC-to-STC, Temperature coefficient); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Pid, Sdml, Tc)

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
51 V
Voc when cold
per panel
33 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,03111,3386.08
Palmdale1,8351,12912,4146.69
Chula Vista1,6961,04311,4736.11
Huntington Beach1,6431,01011,1155.89
Riverside1,6961,04311,4736.21
Santa Clarita1,7241,06011,6636.28
740Jan741Feb950Mar1,050Apr1,037May1,102Jun1,161Jul1,174Aug1,027Sep906Oct779Nov674DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 615 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · Waaree datasheet
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
JA Solar JAM66D45-615/LB615 W≈23.3%−0.31748.316.1product 2025, 2026
Phono Solar PS610M8GFH-24/TNH610 W≈23.8%−0.29353.814.02product 2024, 2025
ZNShine Solar ZXM7-UHLDD144-615/N615 W≈24%−0.28152.914.72product 2024, 2025, 2026
Waaree BiN-21-615615 W≥22.8%−0.28848.915.97product 2026
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About JA Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

JAM54S31-xxx/MR · 152JAM54D41-xxx/MB · 17JAM72D30-xxx/MB · 3JAM54S30-xxx/MR · 1JAM54D30-xxx/MBJAM72D40-xxx/MB

Questions & answers

How efficient is the JA Solar JAM66D45-615/LB?

Calculated from the panel area (2.64 m²): about 23.3% for the 615 W class. 615 W over 2.64 m² equals about 233 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,031 kWh per year per 615 W panel in Los Angeles and about 1,129 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.317 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 16.4% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51 V, Vmp at 74 °C cell = 33 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

JAM66D45-xxx/LB was a PVEL Top Performer in 2025, 2026 (DH, LID+LETID, MSS, PID, TC).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Waaree — datasheet ELITE-R-SERIES-BiN-21-600-635-WEL-EPD-600-635-132-BiN-HC.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2014–2026.
  4. RETC — PV Module Index reports 2023–2026.
  5. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  6. Clean Energy Council (Australia) — Approved PV modules list (as of Oct 8, 2026).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).