UL 61730IEC 61215IEC 61730Fire rating Type 1 (UL 61730)ISO 14001ISO 45001ISO 9001
UL 61730CEC listing
IEC 61215datasheet
IEC 61730datasheet
Fire rating Type 1 (UL 61730)datasheet
ISO 14001factory, datasheet
ISO 45001factory, datasheet
ISO 9001factory, datasheet
Independent reliability testing
Kiwa PVEL Scorecard
5
PVEL Scorecards
Hyundai Energy Solutions named Top Performer, 2017–2025
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.
Inverter compatibility & string sizing
Hyundai Energy Solutions datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
40.6 V
Voc when cold
per panel
25.8 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.
String inverters most named in SoCal permits
Inverter
Max DC input
MPPT
Window source
Panels per string
Tesla 1538000-xx-y
600 V
60–480 V
datasheet
3–14
Solis (Ginlong) S6-EH1P10K-H-US
600 V
80–520 V
datasheet
4–14
Solis (Ginlong) Solis-1P7.6K-4G-US
600 V
100–500 V
datasheet
4–14
Qcells Q.VOLT H7.6SX
498 V
234–498 V
CEC test window
10–12
Microinverters (one per panel)
Microinverter
Recommended module power
Max DC input
MPPT
Voc cold / Vmp hot
Check
DC/AC
Enphase IQ8PLUS-72-2-US
235–440 W
60 V
29–45 V
40.6 / 25.8 V
⚠ Works; below MPPT at peak heat
0.95
APsystems (Alt Power System) DS3-L
265–570 W
60 V
28–45 V
40.6 / 25.8 V
⚠ Works; below MPPT at peak heat
0.35
Enphase IQ8M-72-2-US
260–460 W
60 V
30–45 V
40.6 / 25.8 V
⚠ Works; below MPPT at peak heat
0.85
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
461
11,522
6.08
Palmdale
1,835
505
12,616
6.69
Chula Vista
1,696
466
11,660
6.11
Huntington Beach
1,643
452
11,296
5.89
Riverside
1,696
466
11,660
6.21
Santa Clarita
1,724
474
11,852
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
How efficient is the Hyundai Energy Solutions HiS-C275RG(BK)?
The Hyundai Energy Solutions datasheet guarantees at least 17% module efficiency for the 275 W class (up to 17.6% for 285 W). 275 W over 1.64 m² equals about 168 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 461 kWh per year per 275 W panel in Los Angeles and about 505 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.35 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18% below the STC rating.
How many panels fit on one string?
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 40.6 V, Vmp at 74 °C cell = 25.8 V). Final design must follow the inverter manual and NEC 690.7.
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
Building permits — Southern California permit portals. Equipment matched from permit descriptions.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).