Solar panelHyundai Energy Solutions

Hyundai Energy Solutions HiN-S360XG(BK)

120 half-cut cells. Power classes 350–375 W in the CEC list; datasheet covers 360–380 W.

CEC listed · Jan 21, 2022UL 6173025-yr product + 25-yr performance warranty
Power class
  • Power (STC)360 WCEC nameplate
  • Efficiency≥19.8%datasheet minimum
  • %/°C Pmax−0.36CEC test: −0.334
  • Output at year 2586%performance warranty

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · Hyundai Energy Solutions datasheet · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
HiN-S350XG(BK)350 W40.2011.0433.4010.48≈19.2%327 WJan 21, 2022
HiN-S355XG(BK)355 W40.4011.1433.6010.57≈19.5%331 WJan 21, 2022
HiN-S360XG(BK)360 W40.6011.2433.8010.66≥19.8%336 WJan 21, 2022
HiN-S365XG(BK)365 W40.8011.3334.0010.74≥20.0%341 WJan 21, 2022
HiN-S370XG(BK)370 W41.0011.4234.2010.82≥20.3%346 WJan 21, 2022
HiN-S375XG(BK)375 W41.2011.5134.4010.91≥20.6%350 WJan 21, 2022
≈ efficiency = Pmax ÷ panel area 1.822 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

Hyundai Energy Solutions datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

Hyundai Energy Solutions datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.36 %/°C−0.334 %/°C
Voc coefficient β−0.29 %/°C−0.263 %/°C
Isc coefficient α+0.05 %/°C+0.048 %/°C
Vmp coefficient≈ −0.41 %/°C—
Operating cell temperature—NOCT 45.6 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
350 W259.9 W31.59 V × 8.23 A65 W93%
355 W263.7 W31.78 V × 8.3 A65.9 W93%
360 W267.5 W31.97 V × 8.37 A66.9 W93%
365 W271.1 W32.16 V × 8.43 A67.8 W93%
370 W274.8 W32.34 V × 8.49 A68.7 W93%
375 W278.7 W32.53 V × 8.57 A69.7 W93%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Independent reliability testing

Kiwa PVEL Scorecard
5
PVEL Scorecards
Hyundai Energy Solutions named Top Performer, 2017–2025
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

Hyundai Energy Solutions datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.3 V
Voc when cold
per panel
27 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.3 / 27 V⚠ Works; below MPPT at peak heat1.24
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.3 / 27 V✗ Not a match: module voltage below MPPT range0.95
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.3 / 27 V⚠ Works; below MPPT at peak heat0.46
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.3 / 27 V⚠ Works; below MPPT at peak heat1.11
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.3 / 27 V⚠ Works; below MPPT at peak heat1.03
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67660311,4646.08
Palmdale1,83566112,5516.69
Chula Vista1,69661111,6016.11
Huntington Beach1,64359111,2385.89
Riverside1,69661111,6016.21
Santa Clarita1,72462111,7926.28
748Jan749Feb961Mar1,062Apr1,049May1,114Jun1,174Jul1,187Aug1,038Sep916Oct787Nov681DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 360 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Hyundai Energy Solutions HiN-S360XG(BK)360 W≥19.8%−0.33440.611.24brand 5×—
LONGi LR4-60HPB-360M360 W≈20.3%−0.33940.811.33product 2021, 2022193
REC Group REC360AA360 W≈21.4%−0.27944.110.23brand 9× (2016–2025)30
Trina Solar TSM-360DE06X.05(II)360 W≈19.8%−0.33944.810.3product 202223
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

About Hyundai Energy Solutions

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits

Other series by SoCal permits

HiN-TxxxNF(BK) · 37HiS-SxxxYH(BK) · 14HiS-TxxxNF(BK) · 8HiA-SxxxHG · 1HiS-CxxxRG(BK)HiN-TxxxNI

Questions & answers

How efficient is the Hyundai Energy Solutions HiN-S360XG(BK)?

The Hyundai Energy Solutions datasheet guarantees at least 19.8% module efficiency for the 360 W class (up to 20.6% for 375 W). 360 W over 1.82 m² equals about 198 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 603 kWh per year per 360 W panel in Los Angeles and about 661 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.36 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.3 V, Vmp at 74 °C cell = 27 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

25 years on the product and 25 years on performance: at least 86% after 25 years (manufacturer datasheet).

How big and heavy is it?

69.1 × 40.9 × 1.38 in (1,755 × 1,038 × 35 mm), 45.2 lb (20.5 kg).

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Hyundai Energy Solutions was named a Top Performer in 5 Scorecards (2017–2025).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Hyundai Energy Solutions — datasheet [US] XG(BK) Series(PERC) 360~380W.
  3. Hyundai Energy Solutions — document library on the manufacturer’s website (links above).
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2017–2025.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).