144 half-cut cells. Power classes 430–470 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| HiG-S430XI | 430 W | 49.20 | 11.19 | 40.60 | 10.60 | ≈19.6% | 399 W | Sep 21, 2021 |
| HiG-S435XI | 435 W | 49.40 | 11.26 | 40.80 | 10.67 | ≈19.9% | 404 W | Sep 21, 2021 |
| HiG-S440XI | 440 W | 49.60 | 11.34 | 41.00 | 10.74 | ≈20.1% | 408 W | Sep 21, 2021 |
| HiG-S445XI | 445 W | 49.80 | 11.42 | 41.20 | 10.81 | ≈20.3% | 413 W | Sep 21, 2021 |
| HiG-S450XI | 450 W | 50.00 | 11.50 | 41.40 | 10.87 | ≈20.5% | 418 W | Sep 21, 2021 |
| HiG-S455XI | 455 W | 50.20 | 11.59 | 41.60 | 10.94 | ≈20.8% | 423 W | Sep 21, 2021 |
| HiG-S460XI | 460 W | 50.40 | 11.67 | 41.80 | 11.01 | ≈21.0% | 428 W | Sep 21, 2021 |
| HiG-S465XI | 465 W | 50.60 | 11.74 | 42.00 | 11.08 | ≈21.2% | 432 W | Sep 21, 2021 |
| HiG-S470XI | 470 W | 50.80 | 11.81 | 42.20 | 11.14 | ≈21.5% | 437 W | Sep 21, 2021 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.373 %/°C |
| Voc coefficient β | −0.298 %/°C |
| Isc coefficient α | +0.047 %/°C |
| Operating cell temperature | NOCT 45 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 430 W | 322 W | 37.95 V × 8.48 A | 84.8 W | 99% |
| 435 W | 325.7 W | 38.14 V × 8.54 A | 85.8 W | 99% |
| 440 W | 329.4 W | 38.33 V × 8.6 A | 86.8 W | 99% |
| 445 W | 333.2 W | 38.51 V × 8.65 A | 87.7 W | 99% |
| 450 W | 336.7 W | 38.7 V × 8.7 A | 88.7 W | 99% |
| 455 W | 340.5 W | 38.89 V × 8.76 A | 89.7 W | 99% |
| 460 W | 344.3 W | 39.07 V × 8.81 A | 90.7 W | 99% |
| 465 W | 348.2 W | 39.26 V × 8.87 A | 91.7 W | 99% |
| 470 W | 351.7 W | 39.45 V × 8.92 A | 92.6 W | 99% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 8–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 53.4 / 32.9 V | ✗ Not a match: module voltage below MPPT range | 1.18 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 53.4 / 32.9 V | ✓ Within range | 0.58 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 53.4 / 32.9 V | ✓ Within range | 1.38 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 53.4 / 32.9 V | ✓ Within range | 1.29 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 754 | 12,067 | 6.08 |
| Palmdale | 1,835 | 826 | 13,212 | 6.69 |
| Chula Vista | 1,696 | 763 | 12,211 | 6.11 |
| Huntington Beach | 1,643 | 739 | 11,830 | 5.89 |
| Riverside | 1,696 | 763 | 12,211 | 6.21 |
| Santa Clarita | 1,724 | 776 | 12,413 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Hyundai Energy Solutions HiG-S450XI | 450 W | ≈20.5% | −0.373 | 50 | 11.5 | brand 5× | — |
| Qcells Q.TRON BLK M-G2+ 445 | 445 W | ≈22.8% | −0.276 | 40.16 | 13.98 | brand 11× (2016–2026) | 40 |
| REC Group REC450AA Pure-RX | 450 W | ≈22.3% | −0.248 | 65.1 | 8.81 | brand 9× (2016–2025) | 33 |
| Aptos Solar DNA-120-MF10-450W | 450 W | ≥20.8% | −0.355 | 41.18 | 13.85 | — | 22 |
Calculated from the panel area (2.19 m²): about 20.5% for the 450 W class. 450 W over 2.19 m² equals about 205 W per square meter.
PVWatts v8 with typical-year weather gives about 754 kWh per year per 450 W panel in Los Angeles and about 826 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.373 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.3% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 53.4 V, Vmp at 74 °C cell = 32.9 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 53.4 V vs max input 60 V; Vmp when hot 32.9 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
This exact series is not in published PVEL Top Performer tables; Hyundai Energy Solutions was named a Top Performer in 5 Scorecards (2017–2025).