60 cells, PERC. Power classes 290–330 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| HiD-S290RG(BK) | 290 W | 39.60 | 9.75 | 31.90 | 9.20 | ≈17.3% | 262 W | Sep 3, 2019 |
| HiD-S295RG(BK) | 295 W | 39.80 | 9.78 | 32.30 | 9.25 | ≈17.6% | 267 W | Sep 3, 2019 |
| HiD-S300RG(BK) | 300 W | 40.00 | 9.83 | 32.60 | 9.31 | ≈17.9% | 271 W | Sep 3, 2019 |
| HiD-S305RG(BK) | 305 W | 40.10 | 9.90 | 32.80 | 9.38 | ≈18.2% | 278 W | Sep 3, 2019 |
| HiD-S310RG(BK) | 310 W | 40.30 | 9.94 | 33.10 | 9.45 | ≈18.5% | 283 W | Sep 3, 2019 |
| HiD-S315RG(BK) | 315 W | 40.50 | 9.99 | 33.40 | 9.51 | ≈18.8% | 287 W | Mar 11, 2021 |
| HiD-S320RG(BK) | 320 W | 40.60 | 10.04 | 33.70 | 9.57 | ≈19.1% | 292 W | Mar 11, 2021 |
| HiD-S325RG(BK) | 325 W | 40.80 | 10.09 | 34.00 | 9.62 | ≈19.4% | 297 W | Mar 11, 2021 |
| HiD-S330RG(BK) | 330 W | 41.00 | 10.14 | 34.30 | 9.68 | ≈19.7% | 302 W | Mar 11, 2021 |
| Datasheet | CEC listing test | |
|---|---|---|
| Pmax coefficient γ | −0.39 %/°C | −0.445 %/°C |
| Voc coefficient β | −0.31 %/°C | −0.319 %/°C |
| Isc coefficient α | +0.03 %/°C | +0.030 %/°C |
| Vmp coefficient | ≈ −0.42 %/°C | — |
| Operating cell temperature | — | NOCT 44.9 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 290 W | 202.7 W | 28.55 V × 7.1 A | 54.4 W | 94% |
| 295 W | 205.6 W | 29 V × 7.09 A | 55.2 W | 94% |
| 300 W | 209.6 W | 29.18 V × 7.18 A | 56.3 W | 94% |
| 305 W | 207.1 W | 28.28 V × 7.32 A | 53.7 W | 88% |
| 310 W | 210.5 W | 28.54 V × 7.38 A | 54.5 W | 88% |
| 315 W | 213.8 W | 28.8 V × 7.42 A | 55.4 W | 88% |
| 320 W | 217.1 W | 29.06 V × 7.47 A | 56.2 W | 88% |
| 325 W | 220.2 W | 29.32 V × 7.51 A | 57 W | 88% |
| 330 W | 223.5 W | 29.58 V × 7.56 A | 57.9 W | 88% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–13 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 4–13 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–13 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 9–11 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 43.2 / 26.3 V | ⚠ Works; below MPPT at peak heat | 1.07 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 43.2 / 26.3 V | ⚠ Works; below MPPT at peak heat | 0.4 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 43.2 / 26.3 V | ⚠ Works; below MPPT at peak heat | 0.95 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 43.2 / 26.3 V | ⚠ Works; below MPPT at peak heat | 0.89 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 520 | 11,950 | 6.08 |
| Palmdale | 1,835 | 569 | 13,084 | 6.69 |
| Chula Vista | 1,696 | 526 | 12,092 | 6.11 |
| Huntington Beach | 1,643 | 509 | 11,715 | 5.89 |
| Riverside | 1,696 | 526 | 12,092 | 6.21 |
| Santa Clarita | 1,724 | 534 | 12,292 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Hyundai Energy Solutions HiD-S310RG(BK) | 310 W | ≈18.5% | −0.445 | 40.3 | 9.94 | brand 5× | — |
| JinkoSolar JKM310M-60HBL | 310 W | ≈18.4% | −0.407 | 40.5 | 9.92 | brand 12× (2014–2026) | 45 |
| REC Group REC310NP | 310 W | ≈19.1% | −0.351 | 40.2 | 10.01 | brand 9× (2016–2025) | 4 |
| Sinotec USA STS-310M3B-60 | 310 W | ≈18.8% | −0.375 | 40.3 | 10.04 | — | 3 |
Calculated from the panel area (1.68 m²): about 18.5% for the 310 W class. 310 W over 1.68 m² equals about 185 W per square meter.
PVWatts v8 with typical-year weather gives about 520 kWh per year per 310 W panel in Los Angeles and about 569 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.39 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.3% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.2 V, Vmp at 74 °C cell = 26.3 V). Final design must follow the inverter manual and NEC 690.7.
10 years on the product and 25 years on performance: at least 80% after 25 years (manufacturer datasheet).
65.9 × 39.4 × 1.3 in (1,675 × 1,001 × 33 mm), 39.7 lb (18 kg).
This exact series is not in published PVEL Top Performer tables; Hyundai Energy Solutions was named a Top Performer in 5 Scorecards (2017–2025).