120 cells. Power classes 290–340 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| HiA-S290HG | 290 W | 38.87 | 9.59 | 31.70 | 9.15 | ≈17.5% | 269 W | Oct 1, 2019 |
| HiA-S295HG | 295 W | 39.05 | 9.68 | 31.93 | 9.24 | ≈17.8% | 274 W | Oct 1, 2019 |
| HiA-S300HG | 300 W | 39.23 | 9.77 | 32.15 | 9.33 | ≈18.1% | 278 W | Oct 1, 2019 |
| HiA-S305HG | 305 W | 39.42 | 9.86 | 32.37 | 9.42 | ≈18.4% | 283 W | Aug 15, 2019 |
| HiA-S310HG | 310 W | 39.58 | 9.95 | 32.58 | 9.51 | ≈18.7% | 288 W | Aug 15, 2019 |
| HiA-S315HG | 315 W | 39.74 | 10.04 | 32.79 | 9.60 | ≈19.0% | 293 W | Aug 15, 2019 |
| HiA-S320HG | 320 W | 39.92 | 10.13 | 33.01 | 9.69 | ≈19.3% | 299 W | Aug 15, 2019 |
| HiA-S325HG | 325 W | 40.10 | 10.43 | 32.71 | 9.93 | ≈19.6% | 304 W | Jan 2, 2020 |
| HiA-S330HG | 330 W | 40.27 | 10.51 | 32.91 | 10.02 | ≈19.9% | 308 W | Jan 2, 2020 |
| HiA-S335HG | 335 W | 40.44 | 10.60 | 33.11 | 10.11 | ≈20.2% | 313 W | Jan 2, 2020 |
| HiA-S340HG | 340 W | 40.62 | 10.69 | 33.31 | 10.21 | ≈20.5% | 318 W | Jan 2, 2020 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.365 %/°C |
| Voc coefficient β | −0.284 %/°C |
| Isc coefficient α | +0.042 %/°C |
| Operating cell temperature | NOCT 44.6 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 290 W | 210.3 W | 29.44 V × 7.14 A | 54.2 W | 93% |
| 295 W | 213.9 W | 29.66 V × 7.21 A | 55.1 W | 93% |
| 300 W | 217.4 W | 29.86 V × 7.28 A | 56 W | 93% |
| 305 W | 221 W | 30.06 V × 7.35 A | 56.9 W | 93% |
| 310 W | 224.6 W | 30.26 V × 7.42 A | 57.8 W | 93% |
| 315 W | 228.2 W | 30.45 V × 7.49 A | 58.8 W | 93% |
| 320 W | 239.3 W | 31.45 V × 7.61 A | 61.6 W | 96% |
| 325 W | 243 W | 31.17 V × 7.8 A | 62.5 W | 96% |
| 330 W | 246.7 W | 31.36 V × 7.87 A | 63.5 W | 96% |
| 335 W | 250.5 W | 31.55 V × 7.94 A | 64.5 W | 96% |
| 340 W | 254.5 W | 31.74 V × 8.02 A | 65.5 W | 96% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–14 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 4–14 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–14 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 9–11 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 42.2 / 26.1 V | ⚠ Works; below MPPT at peak heat | 1.07 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 42.2 / 26.1 V | ⚠ Works; below MPPT at peak heat | 0.4 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 42.2 / 26.1 V | ⚠ Works; below MPPT at peak heat | 0.95 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 42.2 / 26.1 V | ⚠ Works; below MPPT at peak heat | 0.89 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 520 | 11,950 | 6.08 |
| Palmdale | 1,835 | 569 | 13,084 | 6.69 |
| Chula Vista | 1,696 | 526 | 12,092 | 6.11 |
| Huntington Beach | 1,643 | 509 | 11,715 | 5.89 |
| Riverside | 1,696 | 526 | 12,092 | 6.21 |
| Santa Clarita | 1,724 | 534 | 12,292 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Hyundai Energy Solutions HiA-S310HG | 310 W | ≈18.7% | −0.365 | 39.58 | 9.95 | brand 5× | 1 |
| JinkoSolar JKM310M-60HBL | 310 W | ≈18.4% | −0.407 | 40.5 | 9.92 | brand 12× (2014–2026) | 45 |
| REC Group REC310NP | 310 W | ≈19.1% | −0.351 | 40.2 | 10.01 | brand 9× (2016–2025) | 4 |
| Sinotec USA STS-310M3B-60 | 310 W | ≈18.8% | −0.375 | 40.3 | 10.04 | — | 3 |
Calculated from the panel area (1.66 m²): about 18.7% for the 310 W class. 310 W over 1.66 m² equals about 187 W per square meter.
PVWatts v8 with typical-year weather gives about 520 kWh per year per 310 W panel in Los Angeles and about 569 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.365 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.9% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 42.2 V, Vmp at 74 °C cell = 26.1 V). Final design must follow the inverter manual and NEC 690.7.
10 years on the product and 25 years on performance: at least 80% after 25 years (manufacturer datasheet).
65.9 × 39.1 × 1.38 in (1,675 × 992 × 35 mm), 40.8 lb (18.5 kg).
This exact series is not in published PVEL Top Performer tables; Hyundai Energy Solutions was named a Top Performer in 5 Scorecards (2017–2025).