Cali-GrafCali-Graf
Solar panelHyperion Solar

Hyperion Solar HY-DH108P8-405-B

108 half-cut cells, PERC, bifacial, 2.0mm ( 0.079in.) semi-tempered glass. Power classes 390–415 W in the CEC list; datasheet covers 390–410 W.

CEC listed · Feb 1, 2022UL 61730Bifacial · 70 ± 10%PERCMADE IN THAILANDInstalled in 3 SoCal permits
Power class
  • Power (STC)405 WCEC nameplate
  • Efficiency≥20.7%datasheet minimum
  • %/°C Pmax−0.35CEC test: −0.396
  • PTC / STC93%PTC 376 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Hyperion Solar datasheet · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
HY-DH108P8-390-B390 W36.8513.6130.6412.73≥20.0%362 WFeb 1, 2022
HY-DH108P8-395-B395 W36.9813.7030.8412.81≥20.2%367 WFeb 1, 2022
HY-DH108P8-400-B400 W37.0713.7931.0112.90≥20.5%372 WFeb 1, 2022
HY-DH108P8-405-B405 W37.2313.8731.2112.98≥20.7%376 WFeb 1, 2022
HY-DH108P8-410-B410 W37.3213.9531.4513.04≥21.0%381 WFeb 1, 2022
HY-DH108P8-415-B415 W37.4514.0231.6113.13≈21.3%386 WFeb 1, 2022
≈ efficiency = Pmax ÷ panel area 1.953 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

Hyperion Solar datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

Hyperion Solar datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.35 %/°C−0.396 %/°C
Voc coefficient β−0.27 %/°C−0.307 %/°C
Isc coefficient α+0.05 %/°C+0.056 %/°C
Vmp coefficient≈ −0.40 %/°C—
Operating cell temperatureNMOT 42 ± 2 °CNOCT 43.7 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

At normal operating conditions (NMOT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
390 W295.034.9510.9829.1510.15
395 W298.835.0711.0529.2510.22
400 W302.535.1511.1329.4110.29
405 W306.435.3111.1929.6010.35
410 W310.235.3911.2529.8210.40

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
390 W276.8 W27.4 V × 10.1 A72.7 W93%
395 W280.3 W27.58 V × 10.16 A73.6 W93%
400 W283.9 W27.73 V × 10.24 A74.5 W93%
405 W287.5 W27.91 V × 10.3 A75.5 W93%
410 W291 W28.13 V × 10.35 A76.4 W93%
415 W294.5 W28.27 V × 10.42 A77.3 W93%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Hyperion Solar datasheet
Packaging: 36 per pallet · 792 per container

Bifacial performance

NLR SAM module library · Hyperion Solar datasheet
Rear gain depends on mounting height and ground reflectance; flush roof mounts receive little rear light.

Certifications

CEC PV Module List (Oct 7, 2026) · Hyperion Solar datasheet
UL 61730IEC 61215IEC 61730IEC 61701IEC 62716Fire rating Class A (UL 61730)ISO 9001

Inverter compatibility & string sizing

Hyperion Solar datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
39.5 V
Voc when cold
per panel
25.1 V
Vmp when hot
per panel
15
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–15
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–15
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–15
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window10–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V39.5 / 25.1 V⚠ Works; below MPPT at peak heat1.4
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V39.5 / 25.1 V✗ Not a match: module voltage below MPPT range1.07
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V39.5 / 25.1 V⚠ Works; below MPPT at peak heat0.52
Enphase IQ8M-72-2-US260–460 W60 V30–45 V39.5 / 25.1 V⚠ Works; below MPPT at peak heat1.25
Enphase IQ8A-72-2-US295–500 W60 V32–45 V39.5 / 25.1 V✗ Not a match: module voltage below MPPT range1.16
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67667911,5396.08
Palmdale1,83574312,6346.69
Chula Vista1,69668711,6776.11
Huntington Beach1,64366511,3125.89
Riverside1,69668711,6776.21
Santa Clarita1,72469811,8706.28
753Jan754Feb967Mar1,069Apr1,055May1,122Jun1,181Jul1,195Aug1,045Sep922Oct792Nov686DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs HY-DH108P8-xxx-B panels in SoCal

building permits · CSLB License Master
3
Permits naming this series
Jan 2025 – Apr 2025
1
Licensed installers
CSLB license on the permit
2
Jurisdictions so far
LA County (unincorp.) (2), Palmdale (1)

Permits over time

1Jan ’251Feb0Mar1Aprpermits per month
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Installed together with

building permits

Microinverters

Enphase IQ8+
3

Batteries

Enphase IQ Battery 5P
3
Number of permits naming both this panel series and the product; 3 of 3 permits list other equipment.

Compare with similar 405 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Hyperion Solar HY-DH108P8-405-B405 W≥20.7%−0.39637.2313.87—3
Qcells Q.PEAK DUO BLK ML-G10+ 405405 W≥20.6%−0.36245.3411.17product 2022, 2023221
JA Solar JAM54S31-405/MR405 W≈21.3%−0.32937.2313.87product 2023, 2024152
REC Group REC405AA Pure405 W≈22.6%−0.25648.910.3brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Hyperion Solar HY-DH108P8-405-B?

The Hyperion Solar datasheet guarantees at least 20.7% module efficiency for the 405 W class (up to 21% for 410 W). 405 W over 1.95 m² equals about 207 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 679 kWh per year per 405 W panel in Los Angeles and about 743 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.35 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.1% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–15 panels per string (Voc at 2 °C = 39.5 V, Vmp at 74 °C cell = 25.1 V). Final design must follow the inverter manual and NEC 690.7.

How big and heavy is it?

67.8 × 44.6 × 1.18 in (1,722 × 1,134 × 30 mm), 55.6 lb (25.2 kg).

Is it bifacial?

Yes, bifaciality 70 ± 10%. Rear gain depends on mounting height and ground reflectance.

What fire rating does it have?

UL 61730 fire rating Class A per datasheet.

Who installs it in Southern California?

Building permits name this series 3 times (Jan 2025 – Apr 2025). The most active licensed installers are Earthbound Electric LLC.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Hyperion Solar — manufacturer datasheet “MADE IN THAILAND TITAN SOLAR POWER 525 W BASELINE RD”.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Jan 2025 – Feb 2025); City of Palmdale (Apr 2025). Equipment matched from permit descriptions by model number.
  9. Contractors State License Board — License Master (contractor names and license status), as of Oct 5, 2026.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).