108 half-cut cells, PERC, bifacial, 2.0mm ( 0.079in.) semi-tempered glass. Power classes 390–415 W in the CEC list; datasheet covers 390–410 W.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| HY-DH108P8-390-B | 390 W | 36.85 | 13.61 | 30.64 | 12.73 | ≥20.0% | 362 W | Feb 1, 2022 |
| HY-DH108P8-395-B | 395 W | 36.98 | 13.70 | 30.84 | 12.81 | ≥20.2% | 367 W | Feb 1, 2022 |
| HY-DH108P8-400-B | 400 W | 37.07 | 13.79 | 31.01 | 12.90 | ≥20.5% | 372 W | Feb 1, 2022 |
| HY-DH108P8-405-B | 405 W | 37.23 | 13.87 | 31.21 | 12.98 | ≥20.7% | 376 W | Feb 1, 2022 |
| HY-DH108P8-410-B | 410 W | 37.32 | 13.95 | 31.45 | 13.04 | ≥21.0% | 381 W | Feb 1, 2022 |
| HY-DH108P8-415-B | 415 W | 37.45 | 14.02 | 31.61 | 13.13 | ≈21.3% | 386 W | Feb 1, 2022 |
| Datasheet | CEC listing test | |
|---|---|---|
| Pmax coefficient γ | −0.35 %/°C | −0.396 %/°C |
| Voc coefficient β | −0.27 %/°C | −0.307 %/°C |
| Isc coefficient α | +0.05 %/°C | +0.056 %/°C |
| Vmp coefficient | ≈ −0.40 %/°C | — |
| Operating cell temperature | NMOT 42 ± 2 °C | NOCT 43.7 °C |
| Class | Pmax, W | Voc, V | Isc, A | Vmp, V | Imp, A |
|---|---|---|---|---|---|
| 390 W | 295.0 | 34.95 | 10.98 | 29.15 | 10.15 |
| 395 W | 298.8 | 35.07 | 11.05 | 29.25 | 10.22 |
| 400 W | 302.5 | 35.15 | 11.13 | 29.41 | 10.29 |
| 405 W | 306.4 | 35.31 | 11.19 | 29.60 | 10.35 |
| 410 W | 310.2 | 35.39 | 11.25 | 29.82 | 10.40 |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 390 W | 276.8 W | 27.4 V × 10.1 A | 72.7 W | 93% |
| 395 W | 280.3 W | 27.58 V × 10.16 A | 73.6 W | 93% |
| 400 W | 283.9 W | 27.73 V × 10.24 A | 74.5 W | 93% |
| 405 W | 287.5 W | 27.91 V × 10.3 A | 75.5 W | 93% |
| 410 W | 291 W | 28.13 V × 10.35 A | 76.4 W | 93% |
| 415 W | 294.5 W | 28.27 V × 10.42 A | 77.3 W | 93% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–15 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 4–15 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–15 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 10–12 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 39.5 / 25.1 V | ⚠ Works; below MPPT at peak heat | 1.4 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 39.5 / 25.1 V | ✗ Not a match: module voltage below MPPT range | 1.07 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 39.5 / 25.1 V | ⚠ Works; below MPPT at peak heat | 0.52 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 39.5 / 25.1 V | ⚠ Works; below MPPT at peak heat | 1.25 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 39.5 / 25.1 V | ✗ Not a match: module voltage below MPPT range | 1.16 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 679 | 11,539 | 6.08 |
| Palmdale | 1,835 | 743 | 12,634 | 6.69 |
| Chula Vista | 1,696 | 687 | 11,677 | 6.11 |
| Huntington Beach | 1,643 | 665 | 11,312 | 5.89 |
| Riverside | 1,696 | 687 | 11,677 | 6.21 |
| Santa Clarita | 1,724 | 698 | 11,870 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Hyperion Solar HY-DH108P8-405-B | 405 W | ≥20.7% | −0.396 | 37.23 | 13.87 | — | 3 |
| Qcells Q.PEAK DUO BLK ML-G10+ 405 | 405 W | ≥20.6% | −0.362 | 45.34 | 11.17 | product 2022, 2023 | 221 |
| JA Solar JAM54S31-405/MR | 405 W | ≈21.3% | −0.329 | 37.23 | 13.87 | product 2023, 2024 | 152 |
| REC Group REC405AA Pure | 405 W | ≈22.6% | −0.256 | 48.9 | 10.3 | brand 9× (2016–2025) | 66 |
The Hyperion Solar datasheet guarantees at least 20.7% module efficiency for the 405 W class (up to 21% for 410 W). 405 W over 1.95 m² equals about 207 W per square meter.
PVWatts v8 with typical-year weather gives about 679 kWh per year per 405 W panel in Los Angeles and about 743 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.35 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.1% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–15 panels per string (Voc at 2 °C = 39.5 V, Vmp at 74 °C cell = 25.1 V). Final design must follow the inverter manual and NEC 690.7.
67.8 × 44.6 × 1.18 in (1,722 × 1,134 × 30 mm), 55.6 lb (25.2 kg).
Yes, bifaciality 70 ± 10%. Rear gain depends on mounting height and ground reflectance.
UL 61730 fire rating Class A per datasheet.
Building permits name this series 3 times (Jan 2025 – Apr 2025). The most active licensed installers are Earthbound Electric LLC.