144 half-cut cells, bifacial, glass (dual-glass module). Power classes 560–585 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| HNM7-UHLDD144-560/N | 560 W | 50.70 | 14.11 | 42.00 | 13.34 | ≈21.7% | 526 W | Sep 2, 2025 |
| HNM7-UHLDD144-565/N | 565 W | 50.90 | 14.17 | 42.20 | 13.39 | ≈21.9% | 531 W | Sep 2, 2025 |
| HNM7-UHLDD144-570/N | 570 W | 51.10 | 14.23 | 42.40 | 13.45 | ≈22.1% | 536 W | Sep 2, 2025 |
| HNM7-UHLDD144-575/N | 575 W | 51.30 | 14.29 | 42.60 | 13.50 | ≈22.3% | 540 W | Sep 2, 2025 |
| HNM7-UHLDD144-580/N | 580 W | 51.50 | 14.35 | 42.80 | 13.56 | ≈22.5% | 545 W | Sep 2, 2025 |
| HNM7-UHLDD144-585/N | 585 W | 51.70 | 14.41 | 43.00 | 13.61 | ≈22.7% | 550 W | Sep 2, 2025 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.307 %/°C |
| Voc coefficient β | −0.250 %/°C |
| Isc coefficient α | +0.053 %/°C |
| Operating cell temperature | NOCT 46.2 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 560 W | 424.2 W | 39.56 V × 10.72 A | 109.4 W | 98% |
| 565 W | 427.8 W | 39.75 V × 10.76 A | 110.4 W | 98% |
| 570 W | 431.8 W | 39.94 V × 10.81 A | 111.4 W | 98% |
| 575 W | 435.4 W | 40.13 V × 10.85 A | 112.3 W | 98% |
| 580 W | 439.4 W | 40.31 V × 10.9 A | 113.3 W | 98% |
| 585 W | 443.1 W | 40.5 V × 10.94 A | 114.3 W | 98% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 54 / 34.9 V | ✓ Within range | 0.73 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 955 | 11,464 | 6.08 |
| Palmdale | 1,835 | 1,046 | 12,551 | 6.69 |
| Chula Vista | 1,696 | 967 | 11,601 | 6.11 |
| Huntington Beach | 1,643 | 937 | 11,238 | 5.89 |
| Riverside | 1,696 | 967 | 11,601 | 6.21 |
| Santa Clarita | 1,724 | 983 | 11,792 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Hounen Solar America HNM7-UHLDD144-570/N | 570 W | ≈22.1% | −0.307 | 51.1 | 14.23 | brand 1× | — |
| LONGi LR5-72HBD-565M | 565 W | ≈22.1% | −0.354 | 50.25 | 14.16 | product 2026 | 1 |
| ZNShine Solar ZXM7-UHLDD144-570/N | 570 W | ≈22.3% | −0.281 | 51.1 | 14.23 | product 2024, 2025, 2026 | 1 |
| VSUN (Vietnam Sunergy) VSUN570N-144MH | 570 W | ≈22.1% | −0.309 | 51.58 | 13.72 | brand 6× (2021–2026) | 1 |
Calculated from the panel area (2.58 m²): about 22.1% for the 570 W class. 570 W over 2.58 m² equals about 221 W per square meter.
PVWatts v8 with typical-year weather gives about 955 kWh per year per 570 W panel in Los Angeles and about 1,046 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.307 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.9% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 54 V, Vmp at 74 °C cell = 34.9 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 54 V vs max input 60 V; Vmp when hot 34.9 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.
This exact series is not in published PVEL Top Performer tables; Hounen Solar America was named a Top Performer in 1 Scorecard (2026).