CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ
−0.301 %/°C
Voc coefficient β
−0.246 %/°C
Isc coefficient α
+0.042 %/°C
Operating cell temperature
NOCT 46.4 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.
Away from lab conditions — CEC listing test points
Class
Pmax at NOCT
Vmp × Imp at NOCT
Pmax at 200 W/m²
Low-light efficiency vs STC
600 W
456.3 W
44 V × 10.37 A
116.7 W
97%
605 W
460.1 W
44.2 V × 10.41 A
117.7 W
97%
610 W
464 W
44.4 V × 10.45 A
119 W
98%
615 W
468.3 W
44.6 V × 10.5 A
120 W
98%
620 W
471.6 W
44.7 V × 10.55 A
120.9 W
98%
625 W
475.9 W
44.9 V × 10.6 A
121.9 W
97%
630 W
479.9 W
45.1 V × 10.64 A
122.8 W
97%
635 W
483.8 W
45.3 V × 10.68 A
123.8 W
97%
640 W
487.8 W
45.5 V × 10.72 A
124.7 W
97%
645 W
491.7 W
45.7 V × 10.76 A
125.7 W
97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).
Independent reliability testing
Kiwa PVEL Scorecard · RETC PV Module Index
6
PVEL Scorecards
Hengdian Group DMEGC Magnetics named Top Performer, 2021–2026
2025
RETC Overall Highest Achiever
Hengdian Group DMEGC Magnetics, manufacturer level
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.
RETC PV Module Index — Hengdian Group DMEGC Magnetics
Year
Recognition
2025
Overall Highest Achiever
Inverter compatibility & string sizing
CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
60.1 V
Voc when cold
per panel
39.2 V
Vmp when hot
per panel
9
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
String inverters most named in SoCal permits
Inverter
Max DC input
MPPT
Window source
Panels per string
Tesla 1538000-xx-y
600 V
60–480 V
datasheet
2–9
Solis (Ginlong) S6-EH1P10K-H-US
600 V
80–520 V
datasheet
3–9
Solis (Ginlong) Solis-1P7.6K-4G-US
600 V
100–500 V
datasheet
3–9
Qcells Q.VOLT H7.6SX
498 V
234–498 V
CEC test window
6–8
Microinverters (one per panel)
No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
1,039
11,430
6.08
Palmdale
1,835
1,138
12,515
6.69
Chula Vista
1,696
1,052
11,567
6.11
Huntington Beach
1,643
1,019
11,205
5.89
Riverside
1,696
1,052
11,567
6.21
Santa Clarita
1,724
1,069
11,758
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.
About Hengdian Group DMEGC Magnetics
CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index
ManufacturerHengdian Group DMEGC Magnetics
Listed in CEC asHengdian Group DMEGC Magnetics Co., Ltd.
PVEL Top Performer (manufacturer)6 Scorecards (2021–2026)
How efficient is the Hengdian Group DMEGC Magnetics DM620M10T-B78yyy?
Calculated from the panel area (2.79 m²): about 22.2% for the 620 W class. 620 W over 2.79 m² equals about 222 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 1,039 kWh per year per 620 W panel in Los Angeles and about 1,138 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.301 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.6% below the STC rating.
How many panels fit on one string?
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–9 panels per string (Voc at 2 °C = 60.1 V, Vmp at 74 °C cell = 39.2 V). Final design must follow the inverter manual and NEC 690.7.
Has this panel been reliability-tested?
This exact series is not in published PVEL Top Performer tables; Hengdian Group DMEGC Magnetics was named a Top Performer in 6 Scorecards (2021–2026). RETC named Hengdian Group DMEGC Magnetics Overall Highest Achiever in 2025.
Sources
California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).