Cali-GrafCali-Graf
Solar panelHengdian Group DMEGC Magnetics

Hengdian Group DMEGC Magnetics DM445M10RT-B54yyy

108 half-cut cells. Power classes 425–465 W in the CEC list.

CEC listed · Jul 11, 2025UL 61730
Power class
  • Power (STC)445 WCEC nameplate
  • Efficiency≈22.4%calculated from area
  • %/°C Pmax−0.295CEC listing test
  • PTC / STC94.1%PTC 419 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 9 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
DM425M10RT-B54yyy425 W39.3013.8232.9012.92≈21.4%399 WJul 11, 2025
DM430M10RT-B54yyy430 W39.5013.8933.1012.99≈21.6%404 WJul 11, 2025
DM435M10RT-B54yyy435 W39.7013.9633.3013.06≈21.9%409 WJul 11, 2025
DM440M10RT-B54yyy440 W39.9014.0333.5013.13≈22.1%414 WJul 11, 2025
DM445M10RT-B54yyy445 W40.1014.1033.7013.20≈22.4%419 WJul 11, 2025
DM450M10RT-B54yyy450 W40.3014.1733.9013.27≈22.6%424 WJul 11, 2025
DM455M10RT-B54yyy455 W40.5014.2434.1013.34≈22.9%428 WJul 11, 2025
DM460M10RT-B54yyy460 W40.7014.3134.3013.41≈23.1%433 WJul 11, 2025
DM465M10RT-B54yyy465 W40.9014.3834.5013.48≈23.4%438 WJul 11, 2025
≈ efficiency = Pmax ÷ CEC-listed area 1.99 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.295 %/°C
Voc coefficient β−0.232 %/°C
Isc coefficient α+0.047 %/°C
Operating cell temperatureNOCT 46.7 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
425 W318.3 W30.4 V × 10.47 A83 W98%
430 W322.2 W30.6 V × 10.53 A83.8 W97%
435 W325.9 W30.8 V × 10.58 A85 W98%
440 W329.8 W31 V × 10.64 A85.8 W98%
445 W333.8 W31.2 V × 10.7 A87 W98%
450 W336.5 W31.3 V × 10.75 A87.8 W98%
455 W340.5 W31.5 V × 10.81 A88.7 W97%
460 W344.6 W31.7 V × 10.87 A89.9 W98%
465 W348.3 W31.9 V × 10.92 A90.7 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
6
PVEL Scorecards
Hengdian Group DMEGC Magnetics named Top Performer, 2021–2026
2025
RETC Overall Highest Achiever
Hengdian Group DMEGC Magnetics, manufacturer level
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Hengdian Group DMEGC Magnetics

YearRecognition
2025Overall Highest Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
42.2 V
Voc when cold
per panel
28.1 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V42.2 / 28.1 V✗ Not a match: module voltage below MPPT range1.17
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V42.2 / 28.1 V✓ Within range0.57
Enphase IQ8M-72-2-US260–460 W60 V30–45 V42.2 / 28.1 V⚠ Works; below MPPT at peak heat1.37
Enphase IQ8A-72-2-US295–500 W60 V32–45 V42.2 / 28.1 V⚠ Works; below MPPT at peak heat1.28
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67674611,9336.08
Palmdale1,83581713,0656.69
Chula Vista1,69675512,0766.11
Huntington Beach1,64373111,6985.89
Riverside1,69675512,0766.21
Santa Clarita1,72476712,2756.28
779Jan780Feb1,000Mar1,105Apr1,091May1,160Jun1,222Jul1,236Aug1,081Sep953Oct820Nov709DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 445 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)SoCal permits (series)
Hengdian Group DMEGC Magnetics DM445M10RT-B54yyy445 W≈22.4%−0.29540.114.1—brand 6×—
Qcells Q.TRON BLK M-G2+ 445445 W≈22.8%−0.27640.1613.9825 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-440QD440 W≈22.6%−0.29438.9714.2525 / 30 yrbrand 7× (2017–2025)39
Hyundai Energy Solutions HiN-T445NF(BK)445 W≈22.9%−0.2983914.4625 / 30 yrbrand 5× (2017–2025)37
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Hengdian Group DMEGC Magnetics

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index

Other series by SoCal permits

DMxxxG12RT-B66yyyDMxxxM10T-B54yyyDMxxxM10T-B72yyyDMxxxM10T-B78yyy

Questions & answers

How efficient is the Hengdian Group DMEGC Magnetics DM445M10RT-B54yyy?

Calculated from the panel area (1.99 m²): about 22.4% for the 445 W class. 445 W over 1.99 m² equals about 224 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 746 kWh per year per 445 W panel in Los Angeles and about 817 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.295 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.3% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 42.2 V, Vmp at 74 °C cell = 28.1 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 42.2 V vs max input 60 V; Vmp when hot 28.1 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Hengdian Group DMEGC Magnetics was named a Top Performer in 6 Scorecards (2021–2026). RETC named Hengdian Group DMEGC Magnetics Overall Highest Achiever in 2025.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  3. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  4. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2021–2026.
  6. RETC — PV Module Index report.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).