66 cells. 360 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| 66M-360 HJT | 360 W | 48.62 | 9.41 | 40.45 | 8.90 | ≈20.7% | 338 W | Mar 11, 2022 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.313 %/°C |
| Voc coefficient β | −0.251 %/°C |
| Isc coefficient α | +0.027 %/°C |
| Operating cell temperature | NOCT 45.3 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 360 W | 265.7 W | 37.27 V × 7.13 A | 69.9 W | 97% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 51.4 / 33.7 V | ✓ Within range | 1.24 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 51.4 / 33.7 V | ✗ Not a match: module voltage below MPPT range | 0.95 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 51.4 / 33.7 V | ✓ Within range | 0.46 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 51.4 / 33.7 V | ✓ Within range | 1.11 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 51.4 / 33.7 V | ✓ Within range | 1.03 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 603 | 11,464 | 6.08 |
| Palmdale | 1,835 | 661 | 12,551 | 6.69 |
| Chula Vista | 1,696 | 611 | 11,601 | 6.11 |
| Huntington Beach | 1,643 | 591 | 11,238 | 5.89 |
| Riverside | 1,696 | 611 | 11,601 | 6.21 |
| Santa Clarita | 1,724 | 621 | 11,792 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Heliene 66M-360 HJT | 360 W | ≈20.7% | −0.313 | 48.62 | 9.41 | brand 5× | — |
| LONGi LR4-60HPB-360M | 360 W | ≈20.3% | −0.339 | 40.8 | 11.33 | product 2021, 2022 | 193 |
| REC Group REC360AA | 360 W | ≈21.4% | −0.279 | 44.1 | 10.23 | brand 9× (2016–2025) | 30 |
| Trina Solar TSM-360DE06X.05(II) | 360 W | ≈19.8% | −0.339 | 44.8 | 10.3 | product 2022 | 23 |
Calculated from the panel area (1.74 m²): about 20.7% for the 360 W class. 360 W over 1.74 m² equals about 207 W per square meter.
PVWatts v8 with typical-year weather gives about 603 kWh per year per 360 W panel in Los Angeles and about 661 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.313 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 16.2% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.4 V, Vmp at 74 °C cell = 33.7 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the Enphase datasheet: Voc when cold 51.4 V vs max input 60 V; Vmp when hot 33.7 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.
This exact series is not in published PVEL Top Performer tables; Heliene was named a Top Performer in 5 Scorecards (2020–2025).