Cali-GrafCali-Graf
Solar panelHeliene

Heliene 156HC-625 M10 NTYP SL Bifacial

156 half-cut cells, bifacial. Power classes 605–650 W in the CEC list.

CEC listed · Mar 11, 2024UL 61730Bifacial
Power class
  • Power (STC)625 WCEC nameplate
  • Efficiency≈22.4%calculated from area
  • %/°C Pmax−0.297CEC listing test
  • PTC / STC95%PTC 594 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 10 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
156HC-605 M10 NTYP SL Bifacial605 W56.6413.5747.1012.80≈21.7%574 WMar 11, 2024
156HC-610 M10 NTYP SL Bifacial610 W56.7713.6047.5212.84≈21.9%579 WMar 11, 2024
156HC-615 M10 NTYP SL Bifacial615 W56.9213.6447.7512.88≈22.0%584 WMar 11, 2024
156HC-620 M10 NTYP SL Bifacial620 W57.0813.6748.0012.92≈22.2%589 WMar 11, 2024
156HC-625 M10 NTYP SL Bifacial625 W57.2313.7148.2212.96≈22.4%594 WMar 11, 2024
156HC-630 M10 NTYP SL Bifacial630 W57.3813.7548.4013.01≈22.6%598 WMar 11, 2024
156HC-635 M10 NTYP SL Bifacial635 W57.5413.7948.5913.07≈22.8%603 WMar 11, 2024
156HC-640 M10 NTYP SL Bifacial640 W57.6913.8348.7713.12≈22.9%608 WNov 21, 2025
156HC-645 M10 NTYP SL Bifacial645 W57.8513.8649.0113.16≈23.1%613 WNov 21, 2025
156HC-650 M10 NTYP SL Bifacial650 W58.0013.9049.2413.22≈23.3%618 WAug 3, 2026
≈ efficiency = Pmax ÷ CEC-listed area 2.79 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.297 %/°C
Voc coefficient β−0.242 %/°C
Isc coefficient α+0.037 %/°C
Operating cell temperatureNOCT 43.3 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
605 W445.4 W43.24 V × 10.3 A113 W93%
610 W450.8 W43.62 V × 10.33 A114.4 W94%
615 W454.4 W43.84 V × 10.37 A115.3 W94%
620 W458.2 W44.07 V × 10.4 A116.2 W94%
625 W461.7 W44.27 V × 10.43 A117.1 W94%
630 W465.2 W44.43 V × 10.47 A118 W94%
635 W469.2 W44.61 V × 10.52 A119 W94%
640 W472.8 W44.77 V × 10.56 A119.9 W94%
645 W476.5 W44.99 V × 10.59 A120.9 W94%
650 W481 W45.2 V × 10.64 A122 W94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard
5
PVEL Scorecards
Heliene named Top Performer, 2020–2025
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
60.4 V
Voc when cold
per panel
40.3 V
Vmp when hot
per panel
9
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–9
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet2–9
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–9
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window6–8

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,04811,5226.08
Palmdale1,8351,14712,6166.69
Chula Vista1,6961,06011,6606.11
Huntington Beach1,6431,02711,2965.89
Riverside1,6961,06011,6606.21
Santa Clarita1,7241,07811,8526.28
752Jan753Feb966Mar1,067Apr1,054May1,120Jun1,180Jul1,194Aug1,044Sep921Oct791Nov685DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 625 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
Heliene 156HC-625 M10 NTYP SL Bifacial625 W≈22.4%−0.29757.2313.71brand 5×
Canadian Solar CS7N-630MB-AG630 W≈20.5%−0.39044.218.23product 2024
Hyundai Energy Solutions HiS-T625NJ625 W≈22.6%−0.29457.1513.82brand 5× (2017–2025)
JinkoSolar JKM625N-66HL4M-BDV625 W≈23.1%−0.29949.2816.14product 2025
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

About Heliene

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits

Other series by SoCal permits

108HC-xxx M10 SL · 1108HC-xxx M10 NTYP SL Bifacial144HC-xxx M10 NTYP SL Bifacial108HC-xxx M10 NTYP SL144HC-xxx M10 SL Bifacial156HC-xxx M10 SL Bifacial

Questions & answers

How efficient is the Heliene 156HC-625 M10 NTYP SL Bifacial?

Calculated from the panel area (2.79 m²): about 22.4% for the 625 W class. 625 W over 2.79 m² equals about 224 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,048 kWh per year per 625 W panel in Los Angeles and about 1,147 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.297 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.4% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–9 panels per string (Voc at 2 °C = 60.4 V, Vmp at 74 °C cell = 40.3 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Heliene was named a Top Performer in 5 Scorecards (2020–2025).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Hyundai Energy Solutions — datasheet [US] NJ(HiS) Series (N TOPCon Bifacial) 635~645W.
  3. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR PRODUCT.
  4. Heliene — document library on the manufacturer’s website (links above).
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2020–2025.
  6. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).