144 half-cut cells, bifacial. Power classes 440–460 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| 144HC-440 Bifacial | 440 W | 50.43 | 11.17 | 41.93 | 10.51 | ≈19.9% | 411 W | Aug 11, 2021 |
| 144HC-450 Bifacial | 450 W | 50.74 | 11.51 | 42.17 | 10.69 | ≈20.4% | 420 W | Aug 11, 2021 |
| 144HC-460 Bifacial | 460 W | 51.26 | 11.93 | 42.31 | 10.88 | ≈20.8% | 430 W | Aug 11, 2021 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.338 %/°C |
| Voc coefficient β | −0.262 %/°C |
| Isc coefficient α | +0.030 %/°C |
| Operating cell temperature | NOCT 45.4 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 440 W | 313.2 W | 38.1 V × 8.22 A | 80 W | 91% |
| 450 W | 320.4 W | 38.32 V × 8.36 A | 81.9 W | 91% |
| 460 W | 327.1 W | 38.45 V × 8.51 A | 83.6 W | 91% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 53.8 / 34.6 V | ✗ Not a match: module voltage below MPPT range | 1.18 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 53.8 / 34.6 V | ✓ Within range | 0.58 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 53.8 / 34.6 V | ✓ Within range | 1.38 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 53.8 / 34.6 V | ✓ Within range | 1.29 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 754 | 12,067 | 6.08 |
| Palmdale | 1,835 | 826 | 13,212 | 6.69 |
| Chula Vista | 1,696 | 763 | 12,211 | 6.11 |
| Huntington Beach | 1,643 | 739 | 11,830 | 5.89 |
| Riverside | 1,696 | 763 | 12,211 | 6.21 |
| Santa Clarita | 1,724 | 776 | 12,413 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Heliene 144HC-450 Bifacial | 450 W | ≈20.4% | −0.338 | 50.74 | 11.51 | brand 5× | — |
| Qcells Q.TRON BLK M-G2+ 445 | 445 W | ≈22.8% | −0.276 | 40.16 | 13.98 | brand 11× (2016–2026) | 40 |
| Hyundai Energy Solutions HiN-T450NF(BK) | 450 W | ≈23.2% | −0.298 | 39.2 | 14.53 | brand 5× (2017–2025) | 37 |
| REC Group REC450AA Pure-RX | 450 W | ≈22.3% | −0.248 | 65.1 | 8.81 | brand 9× (2016–2025) | 33 |
Calculated from the panel area (2.21 m²): about 20.4% for the 450 W class. 450 W over 2.21 m² equals about 204 W per square meter.
PVWatts v8 with typical-year weather gives about 754 kWh per year per 450 W panel in Los Angeles and about 826 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.338 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.5% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 53.8 V, Vmp at 74 °C cell = 34.6 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 53.8 V vs max input 60 V; Vmp when hot 34.6 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.
This exact series is not in published PVEL Top Performer tables; Heliene was named a Top Performer in 5 Scorecards (2020–2025).