132 half-cut cells, PERC. Power classes 470–500 W in the CEC list; datasheet covers 480–500 W.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| 132HC-470 M10 SL | 470 W | 45.25 | 13.21 | 37.70 | 12.48 | ≈19.8% | 443 W | Feb 13, 2023 |
| 132HC-475 M10 SL | 475 W | 45.40 | 13.24 | 37.90 | 12.51 | ≈20.0% | 448 W | Feb 13, 2023 |
| 132HC-480 M10 SL | 480 W | 45.57 | 13.26 | 38.22 | 12.54 | ≥20.2% | 452 W | Feb 13, 2023 |
| 132HC-485 M10 SL | 485 W | 45.77 | 13.28 | 38.49 | 12.56 | ≥20.4% | 457 W | Feb 13, 2023 |
| 132HC-490 M10 SL | 490 W | 46.00 | 13.30 | 38.88 | 12.58 | ≥20.6% | 462 W | Feb 13, 2023 |
| 132HC-495 M10 SL | 495 W | 46.21 | 13.32 | 39.28 | 12.60 | ≥20.9% | 467 W | Feb 13, 2023 |
| 132HC-500 M10 SL | 500 W | 46.41 | 13.34 | 39.62 | 12.62 | ≥21.1% | 472 W | Feb 13, 2023 |
| Datasheet | CEC listing test | |
|---|---|---|
| Pmax coefficient γ | −0.34 %/°C | −0.328 %/°C |
| Voc coefficient β | −0.25 %/°C | −0.250 %/°C |
| Isc coefficient α | +0.05 %/°C | +0.042 %/°C |
| Vmp coefficient | ≈ −0.39 %/°C | — |
| Operating cell temperature | — | NOCT 43.5 °C |
| Class | Pmax, W | Voc, V | Isc, A | Vmp, V | Imp, A |
|---|---|---|---|---|---|
| 480 W | 358.0 | 43.29 | 10.71 | 36.31 | 9.86 |
| 485 W | 362.0 | 43.48 | 10.73 | 36.57 | 9.87 |
| 490 W | 365.0 | 43.70 | 10.75 | 36.94 | 9.88 |
| 495 W | 369.0 | 43.90 | 10.76 | 37.32 | 9.89 |
| 500 W | 373.0 | 44.09 | 10.78 | 37.64 | 9.90 |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 470 W | 342.8 W | 34.14 V × 10.04 A | 89.7 W | 95% |
| 475 W | 345.5 W | 34.32 V × 10.07 A | 90.4 W | 95% |
| 480 W | 349.2 W | 34.61 V × 10.09 A | 91.4 W | 95% |
| 485 W | 352.2 W | 34.86 V × 10.11 A | 92.2 W | 95% |
| 490 W | 356.4 W | 35.21 V × 10.12 A | 93.3 W | 95% |
| 495 W | 360.6 W | 35.57 V × 10.14 A | 94.4 W | 95% |
| 500 W | 364.3 W | 35.88 V × 10.15 A | 95.3 W | 95% |
| Year | Product | Tests |
|---|---|---|
| 2022 | 132HC-M10-SL | PID |
| 2023 | 132HC-M10-SL | LID+LETIDPID |
| 2024 | 132HC-M10-SL | HSSLID+LETIDPID |
| 2022 | 132HC-M10-SL-Bifacial (closely related product name) | PID |
| 2023 | 132HC-M10-SL-Bifacial (closely related product name) | LID+LETIDPID |
| 2024 | 132HC-M10-SL-Bifacial (closely related product name) | HSSLID+LETIDPID |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–12 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–12 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–12 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 8–10 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 48.4 / 31.1 V | ✗ Not a match: module voltage below MPPT range | 1.28 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 48.4 / 31.1 V | ✓ Within range | 0.62 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 48.4 / 31.1 V | ⚠ Works; below MPPT at peak heat | 1.39 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 813 | 11,380 | 6.08 |
| Palmdale | 1,835 | 890 | 12,460 | 6.69 |
| Chula Vista | 1,696 | 823 | 11,516 | 6.11 |
| Huntington Beach | 1,643 | 797 | 11,156 | 5.89 |
| Riverside | 1,696 | 823 | 11,516 | 6.21 |
| Santa Clarita | 1,724 | 836 | 11,706 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | Size | Warranty | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|---|---|
| Heliene 132HC-485 M10 SL | 485 W | ≥20.4% | −0.328 | 45.77 | 13.28 | 82.4 × 44.6 in | 15 / 25 yr | product 2022, 2023, 2024 | — |
| SEG Solar SEG-495-BTD-BG | 495 W | ≈25.3% | −0.290 | 39.9 | 15.82 | 67.8 × 44.6 in | — | product 2023, 2024, 2025, 2026 | 8 |
| Qcells Q.PEAK DUO XL-G10.d 485 | 485 W | ≥20.9% | −0.340 | 53.64 | 11.29 | 87.2 × 41.1 in | 12 / 25 yr | product 2023 | 6 |
| AXITEC AC-450MH/144V | 450 W | ≈21.2% | −0.380 | 50 | 11.47 | — | 15 / 25 yr | — | 1 |
The Heliene datasheet guarantees at least 20.4% module efficiency for the 485 W class (up to 21.1% for 500 W). 485 W over 2.38 m² equals about 204 W per square meter.
PVWatts v8 with typical-year weather gives about 813 kWh per year per 485 W panel in Los Angeles and about 890 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.34 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 48.4 V, Vmp at 74 °C cell = 31.1 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 48.4 V vs max input 60 V; Vmp when hot 31.1 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
15 years on the product and 25 years linear on performance (manufacturer datasheet).
82.4 × 44.6 × 1.38 in (2,094 × 1,134 × 35 mm), 59.5 lb (27 kg).
132HC-M10-SL was a PVEL Top Performer in 2022, 2023, 2024 (HSS, LID+LETID, PID).