132 half-cut cells, PERC. Power classes 470–500 W in the CEC list; datasheet covers 480–500 W.

CEC listed · Feb 13, 2023UL 6173015-yr product + 25-yr performance warrantyPVEL Top Performer 2022, 2023, 2024PERC
Power class
  • Power (STC)485 Wtolerance +3 / −0 %
  • Efficiency≥20.4%datasheet minimum
  • %/°C Pmax−0.34CEC test: −0.328
  • Degradation / yr0.5%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · Heliene datasheet · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
132HC-470 M10 SL470 W45.2513.2137.7012.48≈19.8%443 WFeb 13, 2023
132HC-475 M10 SL475 W45.4013.2437.9012.51≈20.0%448 WFeb 13, 2023
132HC-480 M10 SL480 W45.5713.2638.2212.54≥20.2%452 WFeb 13, 2023
132HC-485 M10 SL485 W45.7713.2838.4912.56≥20.4%457 WFeb 13, 2023
132HC-490 M10 SL490 W46.0013.3038.8812.58≥20.6%462 WFeb 13, 2023
132HC-495 M10 SL495 W46.2113.3239.2812.60≥20.9%467 WFeb 13, 2023
132HC-500 M10 SL500 W46.4113.3439.6212.62≥21.1%472 WFeb 13, 2023
≈ efficiency = Pmax ÷ panel area 2.375 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

Heliene datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

Heliene datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.34 %/°C−0.328 %/°C
Voc coefficient β−0.25 %/°C−0.250 %/°C
Isc coefficient α+0.05 %/°C+0.042 %/°C
Vmp coefficient≈ −0.39 %/°C—
Operating cell temperature—NOCT 43.5 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

At normal operating conditions (NMOT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
480 W358.043.2910.7136.319.86
485 W362.043.4810.7336.579.87
490 W365.043.7010.7536.949.88
495 W369.043.9010.7637.329.89
500 W373.044.0910.7837.649.90

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
470 W342.8 W34.14 V × 10.04 A89.7 W95%
475 W345.5 W34.32 V × 10.07 A90.4 W95%
480 W349.2 W34.61 V × 10.09 A91.4 W95%
485 W352.2 W34.86 V × 10.11 A92.2 W95%
490 W356.4 W35.21 V × 10.12 A93.3 W95%
495 W360.6 W35.57 V × 10.14 A94.4 W95%
500 W364.3 W35.88 V × 10.15 A95.3 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Heliene datasheet
Packaging: 40 per pallet · 620 per container

Certifications

CEC PV Module List (Oct 7, 2026) · Heliene datasheet
UL 61730Fire rating Type 1 (UL 61730)ISO 9001

Warranty & degradation

Heliene datasheet

Independent reliability testing

Kiwa PVEL Scorecard
2022, 2023, 2024
PVEL Top Performer
this series
3
Tests passed as Top Performer
HSS, LID+LETID, PID
5
PVEL Scorecards
Heliene named Top Performer, 2020–2025

PVEL Top Performer tests

YearProductTests
2022132HC-M10-SLPID
2023132HC-M10-SLLID+LETIDPID
2024132HC-M10-SLHSSLID+LETIDPID
2022132HC-M10-SL-Bifacial (closely related product name)PID
2023132HC-M10-SL-Bifacial (closely related product name)LID+LETIDPID
2024132HC-M10-SL-Bifacial (closely related product name)HSSLID+LETIDPID

Tested bill of materials

Details describe the tested sample, not every module of the series.

Inverter compatibility & string sizing

Heliene datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
48.4 V
Voc when cold
per panel
31.1 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V48.4 / 31.1 V✗ Not a match: module voltage below MPPT range1.28
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V48.4 / 31.1 V✓ Within range0.62
Enphase IQ8A-72-2-US295–500 W60 V32–45 V48.4 / 31.1 V⚠ Works; below MPPT at peak heat1.39
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67681311,3806.08
Palmdale1,83589012,4606.69
Chula Vista1,69682311,5166.11
Huntington Beach1,64379711,1565.89
Riverside1,69682311,5166.21
Santa Clarita1,72483611,7066.28
743Jan744Feb954Mar1,054Apr1,041May1,106Jun1,165Jul1,179Aug1,031Sep909Oct782Nov676DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 485 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizeWarrantyPVEL (product / brand)SoCal permits (series)
Heliene 132HC-485 M10 SL485 W≥20.4%−0.32845.7713.2882.4 × 44.6 in15 / 25 yrproduct 2022, 2023, 2024—
SEG Solar SEG-495-BTD-BG495 W≈25.3%−0.29039.915.8267.8 × 44.6 in—product 2023, 2024, 2025, 20268
Qcells Q.PEAK DUO XL-G10.d 485485 W≥20.9%−0.34053.6411.2987.2 × 41.1 in12 / 25 yrproduct 20236
AXITEC AC-450MH/144V450 W≈21.2%−0.3805011.47—15 / 25 yr—1
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

About Heliene

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits

Other series by SoCal permits

108HC-xxx M10 SL · 1108HC-xxx M10 NTYP SL Bifacial144HC-xxx M10 NTYP SL Bifacial156HC-xxx M10 NTYP SL Bifacial108HC-xxx M10 NTYP SL144HC-xxx M10 SL Bifacial

Questions & answers

How efficient is the Heliene 132HC-485 M10 SL?

The Heliene datasheet guarantees at least 20.4% module efficiency for the 485 W class (up to 21.1% for 500 W). 485 W over 2.38 m² equals about 204 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 813 kWh per year per 485 W panel in Los Angeles and about 890 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.34 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 48.4 V, Vmp at 74 °C cell = 31.1 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 48.4 V vs max input 60 V; Vmp when hot 31.1 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

What does the warranty cover?

15 years on the product and 25 years linear on performance (manufacturer datasheet).

How big and heavy is it?

82.4 × 44.6 × 1.38 in (2,094 × 1,134 × 35 mm), 59.5 lb (27 kg).

Has this panel been reliability-tested?

132HC-M10-SL was a PVEL Top Performer in 2022, 2023, 2024 (HSS, LID+LETID, PID).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Heliene — datasheet PERC Cell.
  3. SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
  4. Qcells — manufacturer datasheet “Q.PEAK DUO XL-G10.d ENDURING HIGH PERFORMANCE”.
  5. AXITEC — datasheet AXIworldbipremium bifacial 144 cells asemmbled in US.
  6. Heliene — document library on the manufacturer’s website (links above).
  7. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2020–2025.
  8. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  9. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  10. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  11. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  12. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).