120 half-cut cells. Power classes 365–380 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| 120HC-365 | 365 W | 41.04 | 11.67 | 34.99 | 10.43 | ≈19.9% | 342 W | Jul 1, 2022 |
| 120HC-370 | 370 W | 41.22 | 11.75 | 35.12 | 10.54 | ≈20.2% | 347 W | Jul 1, 2022 |
| 120HC-375 | 375 W | 41.40 | 11.83 | 35.26 | 10.65 | ≈20.5% | 352 W | Jul 1, 2022 |
| 120HC-380 | 380 W | 41.60 | 11.92 | 35.40 | 10.75 | ≈20.8% | 357 W | Jul 1, 2022 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.340 %/°C |
| Voc coefficient β | −0.271 %/°C |
| Isc coefficient α | +0.060 %/°C |
| Operating cell temperature | NOCT 44 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 365 W | 262.7 W | 31.34 V × 8.38 A | 68.5 W | 94% |
| 370 W | 266.4 W | 31.46 V × 8.47 A | 69.5 W | 94% |
| 375 W | 270.3 W | 31.59 V × 8.56 A | 70.5 W | 94% |
| 380 W | 273.9 W | 31.71 V × 8.64 A | 71.5 W | 94% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–13 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–13 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–13 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 9–11 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 43.8 / 28.2 V | ⚠ Works; below MPPT at peak heat | 1.28 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 43.8 / 28.2 V | ✗ Not a match: module voltage below MPPT range | 0.97 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 43.8 / 28.2 V | ✓ Within range | 0.47 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 43.8 / 28.2 V | ⚠ Works; below MPPT at peak heat | 1.14 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 43.8 / 28.2 V | ⚠ Works; below MPPT at peak heat | 1.06 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 620 | 11,782 | 6.08 |
| Palmdale | 1,835 | 679 | 12,900 | 6.69 |
| Chula Vista | 1,696 | 628 | 11,923 | 6.11 |
| Huntington Beach | 1,643 | 608 | 11,550 | 5.89 |
| Riverside | 1,696 | 628 | 11,923 | 6.21 |
| Santa Clarita | 1,724 | 638 | 12,120 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Heliene 120HC 370 | 370 W | ≈20.2% | −0.340 | 41.22 | 11.75 | brand 5× | — |
| LONGi LR4-60HPB-370M | 370 W | ≈20.9% | −0.339 | 41.2 | 11.5 | product 2021, 2022 | 193 |
| Canadian Solar CS3N-375MS {Blk} | 375 W | ≈19% | −0.342 | 43.5 | 11.2 | product 2023 | 46 |
| REC Group REC370AA | 370 W | ≈21.9% | −0.258 | 44.1 | 10.55 | brand 9× (2016–2025) | 30 |
Calculated from the panel area (1.83 m²): about 20.2% for the 370 W class. 370 W over 1.83 m² equals about 202 W per square meter.
PVWatts v8 with typical-year weather gives about 620 kWh per year per 370 W panel in Los Angeles and about 679 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.340 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.8 V, Vmp at 74 °C cell = 28.2 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 43.8 V vs max input 60 V; Vmp when hot 28.2 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
This exact series is not in published PVEL Top Performer tables; Heliene was named a Top Performer in 5 Scorecards (2020–2025).