Cali-GrafCali-Graf
Solar panelHansol Technics

Hansol Technics HA620AE-NGEA0

156 cells. Power classes 610–635 W in the CEC list.

CEC listed · Sep 2, 2025UL 61730
Power class
  • Power (STC)620 WCEC nameplate
  • Efficiency≈22.4%calculated from area
  • %/°C Pmax−0.294CEC listing test
  • PTC / STC95.1%PTC 590 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
HA610AE-NGEA0610 W55.3014.0345.6013.38≈22.0%580 WSep 2, 2025
HA615AE-NGEA0615 W55.4014.1145.8013.44≈22.2%585 WSep 2, 2025
HA620AE-NGEA0620 W55.6014.1945.9013.50≈22.4%590 WSep 2, 2025
HA625AE-NGEA0625 W55.7014.2746.1013.56≈22.6%594 WSep 2, 2025
HA630AE-NGEA0630 W55.9014.3546.3013.62≈22.7%599 WSep 2, 2025
HA635AE-NGEA0635 W56.0014.4346.4013.68≈22.9%604 WSep 2, 2025
≈ efficiency = Pmax ÷ CEC-listed area 2.77 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.294 %/°C
Voc coefficient β−0.245 %/°C
Isc coefficient α+0.045 %/°C
Operating cell temperatureNOCT 43.1 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
610 W461.9 W44.8 V × 10.31 A116 W95%
615 W465.2 W44.9 V × 10.36 A116.9 W95%
620 W469.5 W45.1 V × 10.41 A117.8 W95%
625 W473.4 W45.3 V × 10.45 A118.7 W95%
630 W476.7 W45.4 V × 10.5 A119.6 W95%
635 W480.6 W45.6 V × 10.54 A120.4 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
58.7 V
Voc when cold
per panel
38.3 V
Vmp when hot
per panel
10
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–10
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–10
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–10
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–8

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,03911,4306.08
Palmdale1,8351,13812,5156.69
Chula Vista1,6961,05211,5676.11
Huntington Beach1,6431,01911,2055.89
Riverside1,6961,05211,5676.21
Santa Clarita1,7241,06911,7586.28
746Jan747Feb958Mar1,058Apr1,046May1,111Jun1,170Jul1,184Aug1,035Sep913Oct785Nov679DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 620 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
Hansol Technics HA620AE-NGEA0620 W≈22.4%−0.29455.614.19—
ZNShine Solar ZXM7-UHLDD144-615/N615 W≈24%−0.28152.914.72product 2024, 2025, 2026
JinkoSolar JKM620N-66HL4M-BDV620 W≈23%−0.29949.0816.08product 2025
Waaree BiN-21-620620 W≥22.9%−0.28849.116.02product 2026
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Hansol Technics HA620AE-NGEA0?

Calculated from the panel area (2.77 m²): about 22.4% for the 620 W class. 620 W over 2.77 m² equals about 224 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,039 kWh per year per 620 W panel in Los Angeles and about 1,138 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.294 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 58.7 V, Vmp at 74 °C cell = 38.3 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR PRODUCT.
  3. Waaree — datasheet ELITE-R-SERIES-BiN-21-600-635-WEL-EPD-600-635-132-BiN-HC.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).