96 cells, bifacial. Power classes 430–455 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| HN21RN-48HT430W | 430 W | 34.93 | 15.76 | 29.14 | 14.76 | ≈22.2% | 408 W | Jan 2, 2025 |
| HN21RN-48HT435W | 435 W | 35.13 | 15.82 | 29.30 | 14.85 | ≈22.4% | 413 W | Jan 2, 2025 |
| HN21RN-48HT440W | 440 W | 35.33 | 15.88 | 29.46 | 14.94 | ≈22.7% | 418 W | Jan 2, 2025 |
| HN21RN-48HT445W | 445 W | 35.53 | 15.94 | 29.62 | 15.03 | ≈22.9% | 423 W | Jan 2, 2025 |
| HN21RN-48HT450W | 450 W | 35.73 | 16.00 | 29.78 | 15.12 | ≈23.2% | 428 W | Jan 2, 2025 |
| HN21RN-48HT455W | 455 W | 35.93 | 16.06 | 29.94 | 15.20 | ≈23.5% | 433 W | Jan 2, 2025 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.297 %/°C |
| Voc coefficient β | −0.274 %/°C |
| Isc coefficient α | +0.046 %/°C |
| Operating cell temperature | NOCT 43.2 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 430 W | 318.7 W | 27.23 V × 11.7 A | 81.2 W | 94% |
| 435 W | 322.4 W | 27.38 V × 11.77 A | 82.1 W | 94% |
| 440 W | 326.1 W | 27.53 V × 11.85 A | 83.1 W | 94% |
| 445 W | 329.9 W | 27.68 V × 11.92 A | 84 W | 94% |
| 450 W | 333.6 W | 27.83 V × 11.99 A | 85 W | 94% |
| 455 W | 337.2 W | 27.98 V × 12.05 A | 85.9 W | 94% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–15 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 4–15 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 5–15 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 10–13 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 37.6 / 24.5 V | ⚠ Works; below MPPT at peak heat | 1.52 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 37.6 / 24.5 V | ✗ Not a match: module voltage below MPPT range | 1.16 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 37.6 / 24.5 V | ⚠ Works; below MPPT at peak heat | 0.56 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 37.6 / 24.5 V | ✗ Not a match: module voltage below MPPT range | 1.35 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 37.6 / 24.5 V | ✗ Not a match: module voltage below MPPT range | 1.26 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 737 | 11,799 | 6.08 |
| Palmdale | 1,835 | 807 | 12,918 | 6.69 |
| Chula Vista | 1,696 | 746 | 11,940 | 6.11 |
| Huntington Beach | 1,643 | 723 | 11,567 | 5.89 |
| Riverside | 1,696 | 746 | 11,940 | 6.21 |
| Santa Clarita | 1,724 | 759 | 12,137 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | Warranty | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|---|
| Hanersun HN21RN-48HT440W | 440 W | ≈22.7% | −0.297 | 35.33 | 15.88 | — | brand 2× | — |
| Qcells Q.TRON BLK M-G2+ 440 | 440 W | ≥22.5% | −0.276 | 39.88 | 13.9 | 25 / 25 yr | brand 11× (2016–2026) | 40 |
| Silfab Solar SIL-440QD | 440 W | ≈22.6% | −0.294 | 38.97 | 14.25 | 25 / 30 yr | brand 7× (2017–2025) | 39 |
| Hyundai Energy Solutions HiN-T440NF(BK) | 440 W | ≈22.7% | −0.298 | 38.8 | 14.39 | 25 / 30 yr | brand 5× (2017–2025) | 37 |
Calculated from the panel area (1.94 m²): about 22.7% for the 440 W class. 440 W over 1.94 m² equals about 227 W per square meter.
PVWatts v8 with typical-year weather gives about 737 kWh per year per 440 W panel in Los Angeles and about 807 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.297 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.4% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–15 panels per string (Voc at 2 °C = 37.6 V, Vmp at 74 °C cell = 24.5 V). Final design must follow the inverter manual and NEC 690.7.
Yes. Rear gain depends on mounting height and ground reflectance.
This exact series is not in published PVEL Top Performer tables; Hanersun was named a Top Performer in 2 Scorecards (2024–2025).