Building-integrated solar panelHALEE

HALEE HST-61-E-FP

14 cells, BIPV module. 61 W in the CEC list.

CEC listed · Oct 21, 2022UL 61730Building-integrated (BIPV)
  • Power (STC)61 WCEC nameplate
  • Efficiency≈14.9%calculated from area
  • %/°C Pmax−0.387CEC listing test
  • PTC / STC85.6%PTC 52 W (CEC)

Electrical ratings (STC)

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
HST-61-E-FP61 W9.508.607.608.10≈14.9%52 WOct 21, 2022
≈ efficiency = Pmax ÷ CEC-listed area 0.41 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.387 %/°C
Voc coefficient β−0.263 %/°C
Isc coefficient α+0.028 %/°C
Operating cell temperatureNOCT 60.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
61 W42.7 W6.64 V × 6.43 A11.3 W93%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8
10.1 V
Voc when cold
per panel
6.1 V
Vmp when hot
per panel
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
Integrated roof products are wired per the manufacturer’s system design.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67610211,7576.08
Palmdale1,83511212,8736.69
Chula Vista1,69610311,8976.11
Huntington Beach1,64310011,5265.89
Riverside1,69610311,8976.21
Santa Clarita1,72410512,0946.28
767Jan768Feb986Mar1,089Apr1,075May1,143Jun1,204Jul1,218Aug1,065Sep939Oct807Nov699DeckWh per month · Los Angeles
PVWatts models a standard roof-mounted module; integrated roof products are not modeled separately.
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Questions & answers

How efficient is the HALEE HST-61-E-FP?

Calculated from the panel area (0.41 m²): about 14.9% for the 61 W class. 61 W over 0.41 m² equals about 149 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 102 kWh per year per 61 W panel in Los Angeles and about 112 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.387 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20% below the STC rating.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List (snapshot Oct 7, 2026).
  2. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  3. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).