144 cells, bifacial, glass (dual-glass module). Power classes 525–540 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| GS10-B144-GF-525 | 525 W | 49.25 | 13.36 | 43.33 | 12.12 | ≈20.3% | 490 W | Mar 1, 2023 |
| GS10-B144-GF-530 | 530 W | 49.32 | 13.39 | 43.56 | 12.17 | ≈20.5% | 495 W | Mar 1, 2023 |
| GS10-B144-GF-535 | 535 W | 49.39 | 13.41 | 43.64 | 12.26 | ≈20.7% | 500 W | Mar 1, 2023 |
| GS10-B144-GF-540 | 540 W | 49.46 | 13.45 | 43.88 | 12.31 | ≈20.9% | 505 W | Mar 1, 2023 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.332 %/°C |
| Voc coefficient β | −0.249 %/°C |
| Isc coefficient α | +0.041 %/°C |
| Operating cell temperature | NOCT 45.6 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 525 W | 392.3 W | 38.42 V × 10.21 A | 102.5 W | 98% |
| 530 W | 396 W | 38.62 V × 10.25 A | 103.5 W | 98% |
| 535 W | 399.7 W | 38.69 V × 10.33 A | 104.5 W | 98% |
| 540 W | 403.5 W | 38.91 V × 10.37 A | 105.5 W | 98% |
| Year | Product | Tests |
|---|---|---|
| 2024 | GS10-B144-GF-xxx | DHLID+LETIDMSSPIDTC |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 52.1 / 35.6 V | ⚠ Works; below MPPT at peak heat | 1.39 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 52.1 / 35.6 V | ✓ Within range | 0.68 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 888 | 11,548 | 6.08 |
| Palmdale | 1,835 | 973 | 12,643 | 6.69 |
| Chula Vista | 1,696 | 899 | 11,685 | 6.11 |
| Huntington Beach | 1,643 | 871 | 11,320 | 5.89 |
| Riverside | 1,696 | 899 | 11,685 | 6.21 |
| Santa Clarita | 1,724 | 914 | 11,878 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Goldi Solar GS10-B144-GF 530 | 530 W | ≈20.5% | −0.332 | 49.32 | 13.39 | product 2024 | — |
| SEG Solar SEG-525-BTD-BG | 525 W | ≈26.9% | −0.290 | 41.1 | 16.2 | product 2023, 2024, 2025, 2026 | 8 |
| JA Solar JAM72D30-530/MB | 530 W | ≈21% | −0.330 | 49.3 | 13.72 | product 2023, 2024 | 3 |
| Canadian Solar CS6W-530MB-AG | 530 W | ≈20.6% | −0.324 | 48.8 | 13.8 | product 2024 | 1 |
Calculated from the panel area (2.58 m²): about 20.5% for the 530 W class. 530 W over 2.58 m² equals about 205 W per square meter.
PVWatts v8 with typical-year weather gives about 888 kWh per year per 530 W panel in Los Angeles and about 973 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.332 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.2% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.1 V, Vmp at 74 °C cell = 35.6 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.1 V vs max input 60 V; Vmp when hot 35.6 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.
GS10-B144-GF-xxx was a PVEL Top Performer in 2024 (DH, LID+LETID, MSS, PID, TC).