72 cells. Power classes 320–350 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| GOLDI072F320PY24 | 320 W | 45.70 | 9.05 | 36.90 | 8.68 | ≈17.0% | 294 W | Aug 21, 2020 |
| GOLDI072F325PY24 | 325 W | 45.90 | 9.12 | 37.20 | 8.75 | ≈17.3% | 299 W | Aug 21, 2020 |
| GOLDI072F330PY24 | 330 W | 46.20 | 9.19 | 37.40 | 8.83 | ≈17.6% | 304 W | Aug 21, 2020 |
| GOLDI072F335PY24 | 335 W | 46.50 | 9.26 | 37.70 | 8.90 | ≈17.8% | 308 W | Aug 21, 2020 |
| GOLDI072F340PY24 | 340 W | 46.80 | 9.32 | 37.90 | 8.98 | ≈18.1% | 313 W | Aug 21, 2020 |
| GOLDI072F345PY24 | 345 W | 47.10 | 9.40 | 38.10 | 9.06 | ≈18.4% | 318 W | Aug 21, 2020 |
| GOLDI072F350PY24 | 350 W | 47.30 | 9.48 | 38.40 | 9.12 | ≈18.6% | 322 W | Aug 21, 2020 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.370 %/°C |
| Voc coefficient β | −0.262 %/°C |
| Isc coefficient α | +0.009 %/°C |
| Operating cell temperature | NOCT 46.4 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 320 W | 230.7 W | 33.41 V × 6.9 A | 61.2 W | 96% |
| 325 W | 234.4 W | 33.68 V × 6.96 A | 62.2 W | 96% |
| 330 W | 237.8 W | 33.86 V × 7.02 A | 63.1 W | 96% |
| 335 W | 241.6 W | 34.13 V × 7.08 A | 64.2 W | 96% |
| 340 W | 245.1 W | 34.31 V × 7.14 A | 65.1 W | 96% |
| 345 W | 248.6 W | 34.49 V × 7.21 A | 66 W | 96% |
| 350 W | 252.2 W | 34.76 V × 7.26 A | 67 W | 96% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–12 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–12 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–12 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 8–10 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 49.3 / 30.7 V | ✓ Within range | 1.16 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 49.3 / 30.7 V | ✗ Not a match: module voltage below MPPT range | 0.88 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 49.3 / 30.7 V | ✓ Within range | 0.43 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 49.3 / 30.7 V | ✓ Within range | 1.03 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 49.3 / 30.7 V | ⚠ Works; below MPPT at peak heat | 0.96 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 561 | 11,791 | 6.08 |
| Palmdale | 1,835 | 615 | 12,909 | 6.69 |
| Chula Vista | 1,696 | 568 | 11,931 | 6.11 |
| Huntington Beach | 1,643 | 550 | 11,559 | 5.89 |
| Riverside | 1,696 | 568 | 11,931 | 6.21 |
| Santa Clarita | 1,724 | 578 | 12,128 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Goldi Solar GOLDI072F335PY24 | 335 W | ≈17.8% | −0.370 | 46.5 | 9.26 | brand 2× | — |
| LONGi LR4-60HPB-335M | 335 W | ≈18.5% | −0.337 | 39.9 | 10.76 | product 2021, 2022 | 193 |
| JinkoSolar JKM335M-60HBL | 335 W | ≈19.9% | −0.406 | 40.8 | 10.73 | brand 12× (2014–2026) | 45 |
| REC Group REC340AA | 340 W | ≈20.2% | −0.279 | 43.1 | 10.09 | brand 9× (2016–2025) | 30 |
Calculated from the panel area (1.88 m²): about 17.8% for the 335 W class. 335 W over 1.88 m² equals about 178 W per square meter.
PVWatts v8 with typical-year weather gives about 561 kWh per year per 335 W panel in Los Angeles and about 615 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.370 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.2% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 49.3 V, Vmp at 74 °C cell = 30.7 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the Enphase datasheet: Voc when cold 49.3 V vs max input 60 V; Vmp when hot 30.7 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.
This exact series is not in published PVEL Top Performer tables; Goldi Solar was named a Top Performer in 2 Scorecards (2024–2026).