Cali-GrafCali-Graf
Solar panelGoldi Solar

Goldi Solar GOLDI072F335PY24

72 cells. Power classes 320–350 W in the CEC list.

CEC listed · Aug 21, 2020UL 61730
Power class
  • Power (STC)335 WCEC nameplate
  • Efficiency≈17.8%calculated from area
  • %/°C Pmax−0.370CEC listing test
  • PTC / STC92%PTC 308 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
GOLDI072F320PY24320 W45.709.0536.908.68≈17.0%294 WAug 21, 2020
GOLDI072F325PY24325 W45.909.1237.208.75≈17.3%299 WAug 21, 2020
GOLDI072F330PY24330 W46.209.1937.408.83≈17.6%304 WAug 21, 2020
GOLDI072F335PY24335 W46.509.2637.708.90≈17.8%308 WAug 21, 2020
GOLDI072F340PY24340 W46.809.3237.908.98≈18.1%313 WAug 21, 2020
GOLDI072F345PY24345 W47.109.4038.109.06≈18.4%318 WAug 21, 2020
GOLDI072F350PY24350 W47.309.4838.409.12≈18.6%322 WAug 21, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.88 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.370 %/°C
Voc coefficient β−0.262 %/°C
Isc coefficient α+0.009 %/°C
Operating cell temperatureNOCT 46.4 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
320 W230.7 W33.41 V × 6.9 A61.2 W96%
325 W234.4 W33.68 V × 6.96 A62.2 W96%
330 W237.8 W33.86 V × 7.02 A63.1 W96%
335 W241.6 W34.13 V × 7.08 A64.2 W96%
340 W245.1 W34.31 V × 7.14 A65.1 W96%
345 W248.6 W34.49 V × 7.21 A66 W96%
350 W252.2 W34.76 V × 7.26 A67 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026)
UL 61730IEC 61215

Independent reliability testing

Kiwa PVEL Scorecard
2
PVEL Scorecards
Goldi Solar named Top Performer, 2024–2026
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
49.3 V
Voc when cold
per panel
30.7 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V49.3 / 30.7 V✓ Within range1.16
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V49.3 / 30.7 V✗ Not a match: module voltage below MPPT range0.88
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V49.3 / 30.7 V✓ Within range0.43
Enphase IQ8M-72-2-US260–460 W60 V30–45 V49.3 / 30.7 V✓ Within range1.03
Enphase IQ8A-72-2-US295–500 W60 V32–45 V49.3 / 30.7 V⚠ Works; below MPPT at peak heat0.96
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67656111,7916.08
Palmdale1,83561512,9096.69
Chula Vista1,69656811,9316.11
Huntington Beach1,64355011,5595.89
Riverside1,69656811,9316.21
Santa Clarita1,72457812,1286.28
770Jan770Feb988Mar1,092Apr1,078May1,146Jun1,207Jul1,221Aug1,068Sep942Oct810Nov701DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 335 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · JinkoSolar datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Goldi Solar GOLDI072F335PY24335 W≈17.8%−0.37046.59.26brand 2×—
LONGi LR4-60HPB-335M335 W≈18.5%−0.33739.910.76product 2021, 2022193
JinkoSolar JKM335M-60HBL335 W≈19.9%−0.40640.810.73brand 12× (2014–2026)45
REC Group REC340AA340 W≈20.2%−0.27943.110.09brand 9× (2016–2025)30
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Goldi Solar GOLDI072F335PY24?

Calculated from the panel area (1.88 m²): about 17.8% for the 335 W class. 335 W over 1.88 m² equals about 178 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 561 kWh per year per 335 W panel in Los Angeles and about 615 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.370 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 49.3 V, Vmp at 74 °C cell = 30.7 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 49.3 V vs max input 60 V; Vmp when hot 30.7 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Goldi Solar was named a Top Performer in 2 Scorecards (2024–2026).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2024–2026.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).