Cali-GrafCali-Graf
Solar panelGoldi Solar

Goldi Solar GOLDI060F310PRC24

60 cells. Power classes 295–325 W in the CEC list.

CEC listed · Aug 21, 2020UL 61730
Power class
  • Power (STC)310 WCEC nameplate
  • Efficiency≈19.7%calculated from area
  • %/°C Pmax−0.347CEC listing test
  • PTC / STC92.8%PTC 288 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
GOLDI060F295PRC24295 W39.859.4532.359.12≈18.8%273 WAug 21, 2020
GOLDI060F300PRC24300 W40.109.5332.659.19≈19.1%278 WAug 21, 2020
GOLDI060F305PRC24305 W40.409.6232.879.28≈19.4%283 WAug 21, 2020
GOLDI060F310PRC24310 W40.609.7133.059.38≈19.7%288 WAug 21, 2020
GOLDI060F315PRC24315 W40.859.8233.359.45≈20.0%292 WAug 21, 2020
GOLDI060F320PRC24320 W41.159.9033.609.53≈20.4%297 WAug 21, 2020
GOLDI060F325PRC24325 W41.359.9833.759.63≈20.7%302 WAug 21, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.57 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.347 %/°C
Voc coefficient β−0.242 %/°C
Isc coefficient α+0.002 %/°C
Operating cell temperatureNOCT 46.3 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
295 W214.9 W29.82 V × 7.2 A57.8 W98%
300 W218.5 W30.1 V × 7.26 A58.8 W98%
305 W222.2 W30.3 V × 7.33 A59.7 W98%
310 W225.8 W30.47 V × 7.41 A60.7 W98%
315 W229.5 W30.75 V × 7.47 A61.7 W98%
320 W233.2 W30.98 V × 7.53 A62.7 W98%
325 W236.7 W31.12 V × 7.61 A63.7 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026)
UL 61730IEC 61215

Independent reliability testing

Kiwa PVEL Scorecard
2
PVEL Scorecards
Goldi Solar named Top Performer, 2024–2026
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
42.9 V
Voc when cold
per panel
27.4 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V42.9 / 27.4 V⚠ Works; below MPPT at peak heat1.07
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V42.9 / 27.4 V⚠ Works; below MPPT at peak heat0.4
Enphase IQ8M-72-2-US260–460 W60 V30–45 V42.9 / 27.4 V⚠ Works; below MPPT at peak heat0.95
Enphase IQ8A-72-2-US295–500 W60 V32–45 V42.9 / 27.4 V⚠ Works; below MPPT at peak heat0.89
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67652011,9506.08
Palmdale1,83556913,0846.69
Chula Vista1,69652612,0926.11
Huntington Beach1,64350911,7155.89
Riverside1,69652612,0926.21
Santa Clarita1,72453412,2926.28
780Jan781Feb1,002Mar1,107Apr1,093May1,161Jun1,224Jul1,238Aug1,082Sep955Oct821Nov710DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 310 W panels

CEC PV Module List (Oct 7, 2026) · JinkoSolar datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Goldi Solar GOLDI060F310PRC24310 W≈19.7%−0.34740.69.71brand 2×—
JinkoSolar JKM310M-60HBL310 W≈18.4%−0.40740.59.92brand 12× (2014–2026)45
REC Group REC310NP310 W≈19.1%−0.35140.210.01brand 9× (2016–2025)4
Sinotec USA STS-310M3B-60310 W≈18.8%−0.37540.310.04—3
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Goldi Solar GOLDI060F310PRC24?

Calculated from the panel area (1.57 m²): about 19.7% for the 310 W class. 310 W over 1.57 m² equals about 197 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 520 kWh per year per 310 W panel in Los Angeles and about 569 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.347 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 42.9 V, Vmp at 74 °C cell = 27.4 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Goldi Solar was named a Top Performer in 2 Scorecards (2024–2026).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2024–2026.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).