Solar panelGermanSolar USA

GermanSolar USA GSP 325

60 cells. Power classes 270–355 W in the CEC list.

CEC listed · Apr 21, 2023UL 61730
Power class
  • Power (STC)325 WCEC nameplate
  • Efficiency≈16.4%calculated from area
  • %/°C Pmax−0.406CEC listing test
  • PTC / STC92%PTC 299 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 12 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
GSP-270W270 W37.928.9931.918.46≈16.3%248 WApr 21, 2023
GSP-275W275 W38.329.0832.318.51≈16.6%253 WApr 21, 2023
GSP-280W280 W38.559.1832.558.60≈16.9%258 WApr 21, 2023
GSP-285W285 W38.909.2532.838.68≈17.2%263 WApr 21, 2023
GSP-320W320 W45.159.0238.008.42≈16.2%294 WApr 21, 2023
GSP-325W325 W45.299.0838.238.51≈16.4%299 WApr 21, 2023
GSP-330W330 W45.449.1838.388.60≈16.7%304 WApr 21, 2023
GSP-335W335 W45.659.2138.608.68≈16.9%308 WApr 21, 2023
GSP-340W340 W45.869.3538.808.77≈17.2%313 WApr 21, 2023
GSP-345W345 W46.169.4139.048.85≈17.4%318 WApr 21, 2023
GSP-350W350 W46.509.4839.338.90≈17.7%323 WApr 21, 2023
GSP-355W355 W46.609.5639.628.96≈17.9%327 WApr 21, 2023
≈ efficiency = Pmax ÷ CEC-listed area 1.66 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.406 %/°C
Voc coefficient β−0.324 %/°C
Isc coefficient α+0.053 %/°C
Operating cell temperatureNOCT 44.1 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
270 W209.7 W29.92 V × 7.01 A55.1 W102%
275 W213.6 W30.3 V × 7.05 A56.2 W102%
280 W217.5 W30.52 V × 7.12 A57.2 W102%
285 W221.4 W30.79 V × 7.19 A58.2 W102%
320 W231.7 W35 V × 6.62 A62.5 W98%
325 W235.5 W35.21 V × 6.69 A63.5 W98%
330 W239 W35.35 V × 6.76 A64.5 W98%
335 W242.6 W35.55 V × 6.82 A65.4 W98%
340 W246.4 W35.73 V × 6.89 A66.4 W98%
345 W250.1 W35.95 V × 6.96 A67.5 W98%
350 W253.4 W36.22 V × 7 A68.4 W98%
355 W257 W36.49 V × 7.04 A69.3 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
48.7 V
Voc when cold
per panel
29.6 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V48.7 / 29.6 V✓ Within range1.12
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V48.7 / 29.6 V✗ Not a match: module voltage below MPPT range0.86
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V48.7 / 29.6 V✓ Within range0.42
Enphase IQ8M-72-2-US260–460 W60 V30–45 V48.7 / 29.6 V⚠ Works; below MPPT at peak heat1
Enphase IQ8A-72-2-US295–500 W60 V32–45 V48.7 / 29.6 V⚠ Works; below MPPT at peak heat0.93
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67654511,9836.08
Palmdale1,83559613,1206.69
Chula Vista1,69655112,1266.11
Huntington Beach1,64353411,7475.89
Riverside1,69655112,1266.21
Santa Clarita1,72456012,3276.28
782Jan783Feb1,005Mar1,110Apr1,096May1,165Jun1,227Jul1,241Aug1,085Sep957Oct823Nov712DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 325 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizeWarrantyPVEL (product / brand)SoCal permits (series)
GermanSolar USA GSP 325325 W≈16.4%−0.40645.299.08————
JinkoSolar JKM325M-60HBL325 W≈19.3%−0.40741.110.266.3 × 39.4 in10 / 25 yrbrand 12× (2014–2026)45
Qcells Q.PEAK DUO-G8+ 330330 W≈18.4%−0.34339.7110.5268.5 × 40.6 in25 / 25 yrproduct 202220
LG Electronics LG325N1C-N5325 W≈18.8%−0.34240.910.5766.9 × 40 in25 / 25 yrproduct 20215
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the GermanSolar USA GSP 325?

Calculated from the panel area (1.98 m²): about 16.4% for the 325 W class. 325 W over 1.98 m² equals about 164 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 545 kWh per year per 325 W panel in Los Angeles and about 596 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.406 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 21.1% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–12 panels per string (Voc at 2 °C = 48.7 V, Vmp at 74 °C cell = 29.6 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 48.7 V vs max input 60 V; Vmp when hot 29.6 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Qcells — manufacturer datasheet “Q.PEAK DUO-G8+ 345-360 EN ENDURING HIGH”.
  5. LG Electronics — datasheet Specification Sheet.
  6. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).