Solar panelGermanSolar USA

GermanSolar USA GSP-330W-H

120 half-cut cells. Power classes 275–355 W in the CEC list.

CEC listed · Apr 21, 2023UL 61730
Power class
  • Power (STC)330 WCEC nameplate
  • Efficiency≈16.4%calculated from area
  • %/°C Pmax−0.386CEC listing test
  • PTC / STC92.5%PTC 305 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 11 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
GSP-275W-H275 W37.739.2131.878.63≈16.3%254 WApr 21, 2023
GSP-280W-H280 W38.039.2432.158.71≈16.6%259 WApr 21, 2023
GSP-285W-H285 W38.169.3432.358.81≈16.9%264 WApr 21, 2023
GSP-290W-H290 W38.399.4532.708.87≈17.2%269 WApr 21, 2023
GSP-295W-H295 W38.759.5332.938.96≈17.5%273 WApr 21, 2023
GSP-330W-H330 W45.279.2138.248.63≈16.4%305 WApr 21, 2023
GSP-335W-H335 W45.639.2838.568.69≈16.7%310 WApr 21, 2023
GSP-340W-H340 W45.889.3538.778.77≈16.9%315 WApr 21, 2023
GSP-345W-H345 W46.059.4138.998.85≈17.2%320 WApr 21, 2023
GSP-350W-H350 W46.269.4839.338.90≈17.4%324 WApr 21, 2023
GSP-355W-H355 W46.609.5639.628.96≈17.7%329 WApr 21, 2023
≈ efficiency = Pmax ÷ CEC-listed area 1.69 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.386 %/°C
Voc coefficient β−0.312 %/°C
Isc coefficient α+0.057 %/°C
Operating cell temperatureNOCT 43.8 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
275 W203.9 W30.08 V × 6.78 A52.8 W96%
280 W207.6 W30.35 V × 6.84 A53.7 W96%
285 W211.3 W30.54 V × 6.92 A54.7 W96%
290 W215 W30.87 V × 6.97 A55.6 W96%
295 W218.7 W31.08 V × 7.04 A56.6 W96%
330 W248 W35.81 V × 6.93 A64.4 W98%
335 W251.8 W36.11 V × 6.97 A65.4 W98%
340 W255.5 W36.3 V × 7.04 A66.4 W98%
345 W259.3 W36.51 V × 7.1 A67.4 W98%
350 W263 W36.83 V × 7.14 A68.4 W98%
355 W266.8 W37.1 V × 7.19 A69.3 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
48.5 V
Voc when cold
per panel
29.9 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V48.5 / 29.9 V✓ Within range1.14
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V48.5 / 29.9 V✗ Not a match: module voltage below MPPT range0.87
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V48.5 / 29.9 V✓ Within range0.42
Enphase IQ8M-72-2-US260–460 W60 V30–45 V48.5 / 29.9 V⚠ Works; below MPPT at peak heat1.02
Enphase IQ8A-72-2-US295–500 W60 V32–45 V48.5 / 29.9 V⚠ Works; below MPPT at peak heat0.95
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67655311,6156.08
Palmdale1,83560612,7176.69
Chula Vista1,69656011,7536.11
Huntington Beach1,64354211,3865.89
Riverside1,69656011,7536.21
Santa Clarita1,72456911,9476.28
758Jan759Feb974Mar1,076Apr1,062May1,129Jun1,189Jul1,203Aug1,052Sep928Oct798Nov690DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 330 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
GermanSolar USA GSP-330W-H330 W≈16.4%−0.38645.279.21——
LONGi LR4-60HPB-335M335 W≈18.5%−0.33739.910.76product 2021, 2022193
JinkoSolar JKM330M-60HBL330 W≈19.6%−0.40640.610.61brand 12× (2014–2026)45
Qcells Q.PEAK DUO-G8+ 330330 W≈18.4%−0.34339.7110.52product 202220
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the GermanSolar USA GSP-330W-H?

Calculated from the panel area (2.01 m²): about 16.4% for the 330 W class. 330 W over 2.01 m² equals about 164 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 553 kWh per year per 330 W panel in Los Angeles and about 606 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.386 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–12 panels per string (Voc at 2 °C = 48.5 V, Vmp at 74 °C cell = 29.9 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 48.5 V vs max input 60 V; Vmp when hot 29.9 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Qcells — manufacturer datasheet “Q.PEAK DUO-G8+ 345-360 EN ENDURING HIGH”.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).