Cali-GrafCali-Graf
Solar panelGermanSolar USA

GermanSolar USA GSM10-Agri-275W-CG

56 cells. Power classes 205–330 W in the CEC list.

CEC listed · Oct 1, 2025UL 61730
Power class
  • Power (STC)275 WCEC nameplate
  • Efficiency≈22.7%calculated from area
  • %/°C Pmax−0.296CEC listing test
  • PTC / STC95%PTC 261 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 15 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
GSM10-Agri-205W-CG205 W20.3812.4417.6111.64≈21.8%195 WOct 1, 2025
GSM10-Agri-210W-CG210 W20.4112.7217.6411.90≈22.3%199 WOct 1, 2025
GSM10-Agri-215W-CG215 W20.4413.0017.6712.17≈22.9%204 WOct 1, 2025
GSM10-Agri-220W-CG220 W20.4713.2817.7012.43≈23.4%209 WOct 1, 2025
GSM10-Agri-225W-CG225 W20.5013.5617.7212.69≈23.9%214 WOct 1, 2025
GSM10-Agri-265W-CG265 W26.2112.5022.6411.70≈21.9%252 WOct 1, 2025
GSM10-Agri-270W-CG270 W26.2412.7122.6811.90≈22.3%256 WOct 1, 2025
GSM10-Agri-275W-CG275 W26.2812.9322.7212.11≈22.7%261 WOct 1, 2025
GSM10-Agri-280W-CG280 W26.3213.1422.7512.31≈23.1%266 WOct 1, 2025
GSM10-Agri-285W-CG285 W26.3513.3522.7912.51≈23.6%271 WOct 1, 2025
GSM10-Agri-310W-CG310 W30.5812.5326.4211.73≈22.0%294 WOct 1, 2025
GSM10-Agri-315W-CG315 W30.6212.7126.4611.90≈22.3%299 WOct 1, 2025
GSM10-Agri-320W-CG320 W30.6612.8926.5012.07≈22.7%304 WOct 1, 2025
GSM10-Agri-325W-CG325 W30.7013.0726.5412.24≈23.0%309 WOct 1, 2025
GSM10-Agri-330W-CG330 W30.7413.2526.5912.41≈23.4%314 WOct 1, 2025
≈ efficiency = Pmax ÷ CEC-listed area 0.94 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.296 %/°C
Voc coefficient β−0.228 %/°C
Isc coefficient α+0.044 %/°C
Operating cell temperatureNOCT 43.4 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
205 W148.2 W16 V × 9.26 A38.2 W93%
210 W151.8 W16.03 V × 9.47 A39.1 W93%
215 W155.5 W16.06 V × 9.68 A40 W93%
220 W159.1 W16.08 V × 9.89 A41 W93%
225 W162.6 W16.1 V × 10.1 A41.9 W93%
265 W196.3 W20.73 V × 9.47 A50.7 W96%
270 W200 W20.77 V × 9.63 A51.6 W96%
275 W203.9 W20.81 V × 9.8 A52.6 W96%
280 W207.5 W20.83 V × 9.96 A53.6 W96%
285 W211.3 W20.87 V × 10.12 A54.5 W96%
310 W231.1 W24.18 V × 9.56 A58.3 W94%
315 W234.8 W24.22 V × 9.7 A59.2 W94%
320 W238.5 W24.26 V × 9.83 A60.1 W94%
325 W242.3 W24.29 V × 9.97 A61.1 W94%
330 W246.1 W24.34 V × 10.11 A62 W94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
27.7 V
Voc when cold
per panel
18.9 V
Vmp when hot
per panel
21
Max panels / string
max DC 600 V
4
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet4–21
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet5–21
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet6–21
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window13–18

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V27.7 / 18.9 V✗ Not a match: module voltage below MPPT range0.95
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V27.7 / 18.9 V✗ Not a match: module voltage below MPPT range0.35
Enphase IQ8M-72-2-US260–460 W60 V30–45 V27.7 / 18.9 V✗ Not a match: module voltage below MPPT range0.85
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67646111,5226.08
Palmdale1,83550512,6166.69
Chula Vista1,69646611,6606.11
Huntington Beach1,64345211,2965.89
Riverside1,69646611,6606.21
Santa Clarita1,72447411,8526.28
752Jan753Feb966Mar1,067Apr1,054May1,120Jun1,180Jul1,194Aug1,044Sep921Oct791Nov685DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 275 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, A
GermanSolar USA GSM10-Agri-275W-CG275 W≈22.7%−0.29626.2812.93
Hyundai Energy Solutions HiS-C275RG(BK)275 W≥17%−0.38238.189.15
ZNShine Solar ZXM6-72-275/M275 W≈13.8%−0.52444.648.44
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the GermanSolar USA GSM10-Agri-275W-CG?

Calculated from the panel area (1.21 m²): about 22.7% for the 275 W class. 275 W over 1.21 m² equals about 227 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 461 kWh per year per 275 W panel in Los Angeles and about 505 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.296 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.4% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 4–21 panels per string (Voc at 2 °C = 27.7 V, Vmp at 74 °C cell = 18.9 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Hyundai Energy Solutions — datasheet [Customized Module] RG(BK) Series (PERC) 265~285W.
  3. ZNShine Solar — manufacturer datasheet “ZXM6-72 Series Znshinesolar 5BB Monocrystalline PV Module”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).