Cali-GrafCali-Graf
Solar panelGermanSolar USA

GermanSolar USA GSM10-Agri-335W-AG

72 cells. Power classes 265–425 W in the CEC list.

CEC listed · Oct 1, 2025UL 61730
Power class
  • Power (STC)335 WCEC nameplate
  • Efficiency≈22.8%calculated from area
  • %/°C Pmax−0.296CEC listing test
  • PTC / STC95%PTC 318 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 16 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
GSM10-Agri-265W-AG265 W26.2112.4922.6411.70≈21.9%252 WOct 1, 2025
GSM10-Agri-270W-AG270 W26.2412.7122.6811.90≈22.3%256 WOct 1, 2025
GSM10-Agri-275W-AG275 W26.2812.9222.7212.11≈22.7%261 WOct 1, 2025
GSM10-Agri-280W-AG280 W26.3213.1322.7512.31≈23.1%266 WOct 1, 2025
GSM10-Agri-285W-AG285 W26.3513.3522.7912.51≈23.6%271 WOct 1, 2025
GSM10-Agri-325W-AG325 W32.0312.5327.6811.74≈22.1%309 WOct 1, 2025
GSM10-Agri-330W-AG330 W32.0812.7127.7211.90≈22.4%313 WOct 1, 2025
GSM10-Agri-335W-AG335 W32.1212.8827.7612.07≈22.8%318 WOct 1, 2025
GSM10-Agri-340W-AG340 W32.1613.0527.8112.23≈23.1%323 WOct 1, 2025
GSM10-Agri-345W-AG345 W32.2113.2227.8512.39≈23.5%328 WOct 1, 2025
GSM10-Agri-400W-AG400 W39.2612.5833.9111.80≈22.1%380 WOct 1, 2025
GSM10-Agri-405W-AG405 W39.3112.7233.9711.92≈22.4%385 WOct 1, 2025
GSM10-Agri-410W-AG410 W39.3712.8634.0212.05≈22.7%390 WOct 1, 2025
GSM10-Agri-415W-AG415 W39.4212.9934.0712.18≈22.9%394 WOct 1, 2025
GSM10-Agri-420W-AG420 W39.4713.1334.1312.31≈23.2%399 WOct 1, 2025
GSM10-Agri-425W-AG425 W39.5313.2734.1812.43≈23.5%404 WOct 1, 2025
≈ efficiency = Pmax ÷ CEC-listed area 1.21 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.296 %/°C
Voc coefficient β−0.228 %/°C
Isc coefficient α+0.044 %/°C
Operating cell temperatureNOCT 43.4 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
265 W197.2 W20.86 V × 9.45 A51 W96%
270 W200.9 W20.9 V × 9.61 A52 W96%
275 W204.8 W20.93 V × 9.78 A53 W96%
280 W208.5 W20.96 V × 9.95 A53.9 W96%
285 W212.2 W21 V × 10.11 A54.9 W96%
325 W244.9 W25.49 V × 9.61 A63.2 W97%
330 W248.6 W25.53 V × 9.74 A64.2 W97%
335 W252.5 W25.57 V × 9.88 A65.2 W97%
340 W256.3 W25.61 V × 10.01 A66.2 W97%
345 W260.1 W25.65 V × 10.14 A67.2 W97%
400 W297.6 W30.78 V × 9.67 A76.7 W96%
405 W301.1 W30.84 V × 9.76 A77.6 W96%
410 W304.9 W30.88 V × 9.87 A78.5 W96%
415 W308.6 W30.93 V × 9.98 A79.5 W96%
420 W312.4 W30.98 V × 10.08 A80.5 W96%
425 W315.9 W31.03 V × 10.18 A81.4 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
33.8 V
Voc when cold
per panel
23.1 V
Vmp when hot
per panel
17
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–17
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–17
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet5–17
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window11–14

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V33.8 / 23.1 V✗ Not a match: module voltage below MPPT range1.16
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V33.8 / 23.1 V✗ Not a match: module voltage below MPPT range0.88
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V33.8 / 23.1 V✗ Not a match: module voltage below MPPT range0.43
Enphase IQ8M-72-2-US260–460 W60 V30–45 V33.8 / 23.1 V✗ Not a match: module voltage below MPPT range1.03
Enphase IQ8A-72-2-US295–500 W60 V32–45 V33.8 / 23.1 V✗ Not a match: module voltage below MPPT range0.96
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67656111,7916.08
Palmdale1,83561512,9096.69
Chula Vista1,69656811,9316.11
Huntington Beach1,64355011,5595.89
Riverside1,69656811,9316.21
Santa Clarita1,72457812,1286.28
770Jan770Feb988Mar1,092Apr1,078May1,146Jun1,207Jul1,221Aug1,068Sep942Oct810Nov701DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 335 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · JinkoSolar datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
GermanSolar USA GSM10-Agri-335W-AG335 W≈22.8%−0.29632.1212.88——
LONGi LR4-60HPB-335M335 W≈18.5%−0.33739.910.76product 2021, 2022193
JinkoSolar JKM335M-60HBL335 W≈19.9%−0.40640.810.73brand 12× (2014–2026)45
REC Group REC340AA340 W≈20.2%−0.27943.110.09brand 9× (2016–2025)30
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the GermanSolar USA GSM10-Agri-335W-AG?

Calculated from the panel area (1.47 m²): about 22.8% for the 335 W class. 335 W over 1.47 m² equals about 228 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 561 kWh per year per 335 W panel in Los Angeles and about 615 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.296 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.4% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–17 panels per string (Voc at 2 °C = 33.8 V, Vmp at 74 °C cell = 23.1 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).