Solar panelGermanSolar USA

GermanSolar USA GSM10-108 435

108 cells. Power classes 415–455 W in the CEC list.

CEC listed · Oct 1, 2025UL 61730
Power class
  • Power (STC)435 WCEC nameplate
  • Efficiency≈24.0%calculated from area
  • %/°C Pmax−0.296CEC listing test
  • PTC / STC95.1%PTC 414 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 9 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
GSM10-108-415W415 W39.1013.1233.7512.30≈22.9%394 WOct 1, 2025
GSM10-108-420W420 W39.1513.2633.8012.42≈23.2%399 WOct 1, 2025
GSM10-108-425W425 W39.2013.4033.8612.55≈23.5%404 WOct 1, 2025
GSM10-108-430W430 W39.2613.5333.9112.68≈23.8%409 WOct 1, 2025
GSM10-108-435W435 W39.3113.6733.9712.81≈24.0%414 WOct 1, 2025
GSM10-108-440W440 W39.3713.8034.0212.93≈24.3%419 WOct 1, 2025
GSM10-108-445W445 W39.4213.9434.0713.06≈24.6%424 WOct 1, 2025
GSM10-108-450W450 W39.4714.0734.1313.19≈24.9%428 WOct 1, 2025
GSM10-108-455W455 W39.5314.2134.1813.31≈25.1%433 WOct 1, 2025
≈ efficiency = Pmax ÷ CEC-listed area 1.81 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.296 %/°C
Voc coefficient β−0.228 %/°C
Isc coefficient α+0.044 %/°C
Operating cell temperatureNOCT 43.4 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
415 W290.3 W30.64 V × 9.47 A76.5 W92%
420 W293.5 W30.69 V × 9.57 A77.4 W92%
425 W297.1 W30.74 V × 9.67 A78.4 W92%
430 W300.6 W30.79 V × 9.77 A79.3 W92%
435 W304.3 W30.84 V × 9.87 A80.2 W92%
440 W307.6 W30.89 V × 9.96 A81.1 W92%
445 W311.1 W30.93 V × 10.06 A82 W92%
450 W314.8 W30.99 V × 10.16 A83 W92%
455 W318.1 W31.03 V × 10.25 A83.9 W92%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
41.4 V
Voc when cold
per panel
28.3 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V41.4 / 28.3 V⚠ Works; below MPPT at peak heat1.5
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V41.4 / 28.3 V✗ Not a match: module voltage below MPPT range1.14
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V41.4 / 28.3 V✓ Within range0.56
Enphase IQ8M-72-2-US260–460 W60 V30–45 V41.4 / 28.3 V⚠ Works; below MPPT at peak heat1.34
Enphase IQ8A-72-2-US295–500 W60 V32–45 V41.4 / 28.3 V⚠ Works; below MPPT at peak heat1.25
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67672911,6656.08
Palmdale1,83579812,7726.69
Chula Vista1,69673811,8046.11
Huntington Beach1,64371511,4355.89
Riverside1,69673811,8046.21
Santa Clarita1,72475011,9996.28
761Jan762Feb978Mar1,080Apr1,067May1,134Jun1,194Jul1,208Aug1,057Sep932Oct801Nov693DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 435 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)SoCal permits (series)
GermanSolar USA GSM10-108 435435 W≈24%−0.29639.3113.67———
Canadian Solar CS3N-430MS430 W≈21.8%−0.33245.711.8625 yrproduct 202346
Qcells Q.TRON BLK M-G2+ 435435 W≥22.3%−0.27639.613.8225 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-435QD435 W≈22.3%−0.29438.9414.0525 / 30 yrbrand 7× (2017–2025)39
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the GermanSolar USA GSM10-108 435?

Calculated from the panel area (1.81 m²): about 24% for the 435 W class. 435 W over 1.81 m² equals about 240 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 729 kWh per year per 435 W panel in Los Angeles and about 798 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.296 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.4% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 41.4 V, Vmp at 74 °C cell = 28.3 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 41.4 V vs max input 60 V; Vmp when hot 28.3 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
  3. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  4. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).