Cali-GrafCali-Graf
Solar panelGermanSolar USA

GermanSolar USA GSM-410W-H

120 half-cut cells. Power classes 325–670 W in the CEC list.

CEC listed · Apr 21, 2023UL 61730
Power class
  • Power (STC)410 WCEC nameplate
  • Efficiency≈20.4%calculated from area
  • %/°C Pmax−0.378CEC listing test
  • PTC / STC93.3%PTC 383 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 31 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
GSM-325W-H325 W40.7410.0534.809.34≈19.2%303 WMay 11, 2023
GSM-330W-H330 W40.9210.1134.989.44≈19.5%308 WMay 11, 2023
GSM-335W-H335 W40.9210.2035.169.53≈19.8%312 WMay 11, 2023
GSM-340W-H340 W41.2710.2635.429.60≈20.1%317 WMay 11, 2023
GSM-345W-H345 W39.9811.0232.8610.50≈18.6%321 WApr 21, 2023
GSM-350W-H350 W40.2411.0933.1110.57≈18.9%326 WApr 21, 2023
GSM-355W-H355 W40.5011.1633.3610.64≈19.2%331 WApr 21, 2023
GSM-360W-H360 W40.7711.2233.6510.70≈19.5%335 WApr 21, 2023
GSM-365W-H365 W41.0011.2833.9310.76≈19.7%340 WApr 21, 2023
GSM-370W-H370 W41.2711.3534.2010.82≈20.0%345 WApr 21, 2023
GSM-375W-H375 W41.6111.4334.4510.89≈20.3%350 WApr 21, 2023
GSM-390W-H390 W49.3010.1241.109.49≈19.4%363 WApr 21, 2023
GSM-395W-H395 W49.5010.2341.409.55≈19.7%368 WApr 21, 2023
GSM-400W-H400 W49.8010.2141.709.60≈19.9%373 WApr 21, 2023
GSM-405W-H405 W50.1010.2642.009.65≈20.1%378 WApr 21, 2023
GSM-410W-H410 W50.4010.3042.309.69≈20.4%383 WApr 21, 2023
GSM-415W-H415 W48.0011.0039.6710.46≈18.8%386 WApr 21, 2023
GSM-420W-H420 W48.2611.0639.9210.52≈19.0%391 WApr 21, 2023
GSM-425W-H425 W48.5211.1240.1710.58≈19.2%396 WApr 21, 2023
GSM-430W-H430 W48.7911.1840.4710.63≈19.5%401 WApr 21, 2023
GSM-435W-H435 W49.0111.2440.7610.67≈19.7%405 WApr 21, 2023
GSM-440W-H440 W49.2911.2941.0610.72≈19.9%410 WApr 21, 2023
GSM-445W-H445 W49.5411.3341.3310.77≈20.1%415 WApr 21, 2023
GSM-450W-H450 W49.8011.3841.6010.82≈20.4%420 WApr 21, 2023
GSM-640W-H640 W44.9018.3137.5017.07≈22.0%605 WMar 21, 2024
GSM-645W-H645 W44.9018.3537.7017.11≈22.2%610 WMar 21, 2024
GSM-650W-H650 W45.0018.3937.9017.16≈22.3%615 WMar 21, 2024
GSM-655W-H655 W45.2018.4338.1017.20≈22.5%620 WMar 21, 2024
GSM-660W-H660 W45.4018.4738.3017.24≈22.7%625 WMar 21, 2024
GSM-665W-H665 W45.6018.5138.5017.28≈22.9%630 WMar 21, 2024
GSM-670W-H670 W45.8018.5538.7017.32≈23.0%634 WMar 21, 2024
≈ efficiency = Pmax ÷ CEC-listed area 1.69 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.378 %/°C
Voc coefficient β−0.309 %/°C
Isc coefficient α+0.049 %/°C
Operating cell temperatureNOCT 43.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
325 W243.1 W31.72 V × 7.66 A64.9 W100%
330 W246.9 W31.89 V × 7.74 A66 W100%
335 W250.6 W32.05 V × 7.82 A66.9 W100%
340 W254.3 W32.29 V × 7.88 A67.9 W100%
345 W246.8 W31.26 V × 7.89 A62.2 W90%
350 W250.3 W31.5 V × 7.95 A63.1 W90%
355 W253.9 W31.74 V × 8 A64 W90%
360 W257.6 W32.02 V × 8.04 A65 W90%
365 W261.2 W32.28 V × 8.09 A65.9 W90%
370 W264.7 W32.54 V × 8.14 A66.8 W90%
375 W268.4 W32.78 V × 8.19 A67.7 W90%
390 W284.1 W38.34 V × 7.41 A74.6 W96%
395 W288 W38.62 V × 7.46 A75.6 W96%
400 W291.6 W38.9 V × 7.5 A76.6 W96%
405 W295.3 W39.17 V × 7.54 A77.5 W96%
410 W298.6 W39.45 V × 7.57 A78.4 W96%
415 W305 W37.3 V × 8.18 A75.8 W91%
420 W308.7 W37.54 V × 8.22 A76.7 W91%
425 W312.4 W37.78 V × 8.27 A77.7 W91%
430 W316.2 W38.06 V × 8.31 A78.6 W91%
435 W319.7 W38.33 V × 8.34 A79.5 W91%
440 W323.6 W38.61 V × 8.38 A80.4 W91%
445 W327.2 W38.87 V × 8.42 A81.3 W91%
450 W330.9 W39.12 V × 8.46 A82.2 W91%
640 W477.2 W34.32 V × 13.91 A126 W98%
645 W480.9 W34.5 V × 13.94 A126.9 W98%
650 W484.8 W34.68 V × 13.98 A128 W98%
655 W488.5 W34.87 V × 14.01 A128.9 W98%
660 W492.2 W35.05 V × 14.04 A129.9 W98%
665 W495.9 W35.23 V × 14.08 A130.9 W98%
670 W499.7 W35.41 V × 14.11 A131.9 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
54 V
Voc when cold
per panel
33.4 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V54 / 33.4 V✓ Within range1.41
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V54 / 33.4 V✗ Not a match: module voltage below MPPT range1.08
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V54 / 33.4 V✓ Within range0.53
Enphase IQ8M-72-2-US260–460 W60 V30–45 V54 / 33.4 V✓ Within range1.26
Enphase IQ8A-72-2-US295–500 W60 V32–45 V54 / 33.4 V✓ Within range1.17
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67668711,6826.08
Palmdale1,83575212,7906.69
Chula Vista1,69669511,8216.11
Huntington Beach1,64367411,4525.89
Riverside1,69669511,8216.21
Santa Clarita1,72470712,0166.28
763Jan763Feb979Mar1,082Apr1,069May1,135Jun1,196Jul1,210Aug1,058Sep933Oct802Nov694DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 410 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
GermanSolar USA GSM-410W-H410 W≈20.4%−0.37850.410.3——
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W≈20.9%−0.33745.3711.2product 2022, 2023221
JA Solar JAM54S31-405/MR405 W≈21.3%−0.32937.2313.87product 2023, 2024152
REC Group REC410AA Pure410 W≈22.9%−0.2564910.35brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the GermanSolar USA GSM-410W-H?

Calculated from the panel area (2.01 m²): about 20.4% for the 410 W class. 410 W over 2.01 m² equals about 204 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 687 kWh per year per 410 W panel in Los Angeles and about 752 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.378 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 54 V, Vmp at 74 °C cell = 33.4 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 54 V vs max input 60 V; Vmp when hot 33.4 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  4. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  5. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  6. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  7. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).