120 half-cut cells, bifacial, transparent backsheet. Power classes 440–475 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| GEO-PM10-60TS440 | 440 W | 41.51 | 12.88 | 34.71 | 12.68 | ≈20.4% | 416 W | Oct 1, 2026 |
| GEO-PM10-60TS445 | 445 W | 41.73 | 12.94 | 34.93 | 12.74 | ≈20.6% | 421 W | Oct 1, 2026 |
| GEO-PM10-60TS450 | 450 W | 41.96 | 13.00 | 35.16 | 12.80 | ≈20.8% | 426 W | Oct 1, 2026 |
| GEO-PM10-60TS455 | 455 W | 42.19 | 13.06 | 35.39 | 12.86 | ≈21.1% | 430 W | Oct 1, 2026 |
| GEO-PM10-60TS460 | 460 W | 42.41 | 13.12 | 35.61 | 12.92 | ≈21.3% | 435 W | Oct 1, 2026 |
| GEO-PM10-60TS465 | 465 W | 42.63 | 13.18 | 35.83 | 12.98 | ≈21.5% | 440 W | Oct 1, 2026 |
| GEO-PM10-60TS470 | 470 W | 42.85 | 13.24 | 36.08 | 13.04 | ≈21.8% | 445 W | Oct 1, 2026 |
| GEO-PM10-60TS475 | 475 W | 43.07 | 13.30 | 36.33 | 13.10 | ≈22.0% | 450 W | Oct 1, 2026 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.313 %/°C |
| Voc coefficient β | −0.226 %/°C |
| Isc coefficient α | +0.059 %/°C |
| Operating cell temperature | NOCT 43.3 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 440 W | 333.4 W | 32.09 V × 10.39 A | 82.8 W | 94% |
| 445 W | 337.1 W | 32.3 V × 10.44 A | 83.8 W | 94% |
| 450 W | 341 W | 32.51 V × 10.49 A | 84.7 W | 94% |
| 455 W | 344.8 W | 32.72 V × 10.54 A | 85.7 W | 94% |
| 460 W | 348.6 W | 32.93 V × 10.59 A | 86.6 W | 94% |
| 465 W | 352.3 W | 33.13 V × 10.64 A | 87.5 W | 94% |
| 470 W | 356.4 W | 33.36 V × 10.68 A | 88.6 W | 94% |
| 475 W | 360.6 W | 33.59 V × 10.73 A | 89.6 W | 94% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–13 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–13 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–13 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 9–11 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 44.4 / 28.9 V | ✗ Not a match: module voltage below MPPT range | 1.2 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 44.4 / 28.9 V | ✓ Within range | 0.58 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 44.4 / 28.9 V | ⚠ Works; below MPPT at peak heat | 1.4 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 44.4 / 28.9 V | ⚠ Works; below MPPT at peak heat | 1.3 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 763 | 11,439 | 6.08 |
| Palmdale | 1,835 | 835 | 12,524 | 6.69 |
| Chula Vista | 1,696 | 772 | 11,575 | 6.11 |
| Huntington Beach | 1,643 | 748 | 11,213 | 5.89 |
| Riverside | 1,696 | 772 | 11,575 | 6.21 |
| Santa Clarita | 1,724 | 784 | 11,766 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | SoCal permits (series) |
|---|---|---|---|---|---|---|
| Geo Solar Technology GEO-PM10-60TS 455 | 455 W | ≈21.1% | −0.313 | 42.19 | 13.06 | — |
| Hyundai Energy Solutions HiN-T450NF(BK) | 450 W | ≈23.2% | −0.298 | 39.2 | 14.53 | 37 |
| REC Group REC455AA Pure-RX | 455 W | ≈22.5% | −0.248 | 65.6 | 8.84 | 33 |
| Aptos Solar DNA-120-MF10-455W | 455 W | ≈21% | −0.363 | 41.5 | 13.93 | 22 |
Calculated from the panel area (2.16 m²): about 21.1% for the 455 W class. 455 W over 2.16 m² equals about 211 W per square meter.
PVWatts v8 with typical-year weather gives about 763 kWh per year per 455 W panel in Los Angeles and about 835 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.313 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 16.2% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44.4 V, Vmp at 74 °C cell = 28.9 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 44.4 V vs max input 60 V; Vmp when hot 28.9 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.