120 half-cut cells, bifacial, transparent backsheet. Power classes 475–515 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| GEO-NM10-60TS475 | 475 W | 43.61 | 14.03 | 36.98 | 12.85 | ≈22.0% | 448 W | Oct 1, 2026 |
| GEO-NM10-60TS480 | 480 W | 43.73 | 14.11 | 37.12 | 12.95 | ≈22.2% | 453 W | Oct 1, 2026 |
| GEO-NM10-60TS485 | 485 W | 43.86 | 14.19 | 37.26 | 13.02 | ≈22.5% | 458 W | Oct 1, 2026 |
| GEO-NM10-60TS490 | 490 W | 43.98 | 14.27 | 37.40 | 13.12 | ≈22.7% | 463 W | Oct 1, 2026 |
| GEO-NM10-60TS495 | 495 W | 44.11 | 14.35 | 37.54 | 13.20 | ≈22.9% | 468 W | Oct 1, 2026 |
| GEO-NM10-60TS500 | 500 W | 44.23 | 14.43 | 37.68 | 13.28 | ≈23.1% | 472 W | Oct 1, 2026 |
| GEO-NM10-60TS505 | 505 W | 44.36 | 14.51 | 37.82 | 13.37 | ≈23.4% | 477 W | Oct 1, 2026 |
| GEO-NM10-60TS510 | 510 W | 44.48 | 14.59 | 37.96 | 13.45 | ≈23.6% | 482 W | Oct 1, 2026 |
| GEO-NM10-60TS515 | 515 W | 44.61 | 14.67 | 38.10 | 13.54 | ≈23.8% | 487 W | Oct 1, 2026 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.333 %/°C |
| Voc coefficient β | −0.228 %/°C |
| Isc coefficient α | +0.047 %/°C |
| Operating cell temperature | NOCT 43.3 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 475 W | 360.2 W | 35.13 V × 10.26 A | 91.4 W | 96% |
| 480 W | 364.4 W | 35.26 V × 10.34 A | 92.4 W | 96% |
| 485 W | 367.8 W | 35.39 V × 10.39 A | 93.3 W | 96% |
| 490 W | 372 W | 35.53 V × 10.47 A | 94.4 W | 96% |
| 495 W | 375.7 W | 35.66 V × 10.53 A | 95.3 W | 96% |
| 500 W | 379.3 W | 35.79 V × 10.6 A | 96.2 W | 96% |
| 505 W | 383.3 W | 35.92 V × 10.67 A | 97.2 W | 96% |
| 510 W | 387.1 W | 36.06 V × 10.73 A | 98.2 W | 96% |
| 515 W | 391.1 W | 36.19 V × 10.81 A | 99.2 W | 96% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–12 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–12 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–12 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 8–10 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 46.4 / 30.6 V | ✗ Not a match: module voltage below MPPT range | 1.3 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 46.4 / 30.6 V | ✓ Within range | 0.63 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 46.4 / 30.6 V | ⚠ Works; below MPPT at peak heat | 1.42 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 830 | 11,615 | 6.08 |
| Palmdale | 1,835 | 908 | 12,717 | 6.69 |
| Chula Vista | 1,696 | 840 | 11,753 | 6.11 |
| Huntington Beach | 1,643 | 813 | 11,386 | 5.89 |
| Riverside | 1,696 | 840 | 11,753 | 6.21 |
| Santa Clarita | 1,724 | 853 | 11,947 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | SoCal permits (series) |
|---|---|---|---|---|---|---|
| Geo Solar Technology GEO-NM10-60TS 495 | 495 W | ≈22.9% | −0.333 | 44.11 | 14.35 | — |
| SEG Solar SEG-495-BTD-BG | 495 W | ≈25.3% | −0.290 | 39.9 | 15.82 | 8 |
| Qcells Q.PEAK DUO XL-G10.d 495 | 495 W | ≥21.4% | −0.340 | 53.71 | 11.34 | 6 |
| AXITEC AC-530MH/144V | 530 W | ≥20.5% | −0.366 | 49.3 | 13.72 | 1 |
Calculated from the panel area (2.16 m²): about 22.9% for the 495 W class. 495 W over 2.16 m² equals about 229 W per square meter.
PVWatts v8 with typical-year weather gives about 830 kWh per year per 495 W panel in Los Angeles and about 908 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.333 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.2% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 46.4 V, Vmp at 74 °C cell = 30.6 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 46.4 V vs max input 60 V; Vmp when hot 30.6 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.